Accomodation synoptophore in the treatment of convergence insufficiency


Sarojini Devi Eye Hospital and Institute of Ophthabnology, Hyderabad, India

Correspondence Address:
R Hanumanth Reddy
Sarojini Devi Eye Hospital and Institute of Ophthalmology, Hyderabad, (A.P.)
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


PMID: 6677591

Rights and PermissionsRights and Permissions

How to cite this article:
Reddy R H, Vidyavati, Divakaran A. Accomodation synoptophore in the treatment of convergence insufficiency. Indian J Ophthalmol 1983;31:367-8

How to cite this URL:
Reddy R H, Vidyavati, Divakaran A. Accomodation synoptophore in the treatment of convergence insufficiency. Indian J Ophthalmol [serial online] 1983 [cited 2020 Apr 4];31:367-8. Available from: http://www.ijo.in/text.asp?1983/31/4/367/27556

Convergence and accomodation are -sub loosely linked. Still, physiologically, in the young, convergence function is always associ­ated with a capacity to accommodate. Consequently any binocular training to be successful, must necessarily involve the simulation of the physiological conditions viz., close focusing. This is even more important in a patient with an abnormal accomodation and convergence relationship, as in convergence insufficiency. A person using a binocular device i.e., a common synoptophore, gets tired if he is forced to converge at a short distance while accomoda­ting for infinity. Conversely, the new AS-1, designed after Bangerter, meets the funda­mental requirement and provides a continuou­sly adjustable accomodation demand along with the physiologically normal enlargement of the image. We have studied the use of this instrument in the treatment of conver­gence insufficiency and are presenting the results of the same.


  Materials and methods Top


The instrument used is the new AS-1, designed after Bangerter. It is so designed optically as to give, in addition to the facili­ties of a normal synoptophore, the ability to make a continuously adjustable accomoda­tion demand ranging from 0-10 D. This is: effected by using the pedal switches, and the accomodation can be read off a scale on the left arm of the instrument. The instrument is provided with Recco discs that make rapid picture changing possible. There are 8 slides, 2 for small children, 2 for school going children, 2 for. adolescents and. 2 for adults. They are of varying degrees and provide less contrast and more contrast pictures especially selected to make the training interesting and instructive to the various age groups. There are a series of them for the simultaneous perception and fusion and, fusion and stereopsis testing.

Twenty four patients were studied on a double blind basis. Patients selected were those who had symptoms but did not manifest tropia, and whose fusion width was less than 10° on the normal synoptophore. 12 out of these were treated on the normal synopto­phore while the others were given exercises using the AS-l. All these patients were given biweekly sessions of treatment for 4 weeks. On the accomodation synoptophore, the exercises were given to the patient by presenting the object to the patient's eyes at a continuously adjustable distance and size, matching the angle of convercence at any given moment [Figure - 1][Figure - 2]


  Observations Top


Analysis of results showed that the 12 cases treated on the AS-1 developed a better fusion width than those put on the N.S. [Figure - 1][Figure - 2]. There was an average of 40" increase with normal synoptophore and about 80% increase with the AS--1.


  Summary Top


In treating a convergence insufficiency, if physiological conditions are simulated, the convergence impulse is much larger than when a common synoptophore is used. The patients showed a remarkably superior impro­vement in their fusion width.[1]

 
  References Top

1.
Bangerter A. 1975, Concilium Europaeum Strabismi Studio Deditum and the Swiss Strabology Congress.  Back to cited text no. 1
    


    Figures

  [Figure - 1], [Figure - 2]



 

Top
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
Materials and me...
Observations
Summary
References
Article Figures

 Article Access Statistics
    Viewed8495    
    Printed102    
    Emailed13    
    PDF Downloaded0    
    Comments [Add]    

Recommend this journal