Year : 1989  |  Volume : 37  |  Issue : 4  |  Page : 182-183

Tear film flow and stability in normal Indian subjects


34-9J-Medical Enclave, Rohtak, India

Correspondence Address:
A K Khurana
34-9J-Medical Enclave, Rohtak
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


PMID: 2638306

Rights and PermissionsRights and Permissions

Tear film flow and stability studies were carried out in healthy population by Schirmer's test-1 and tear film break-up-time (BUT) measurements, respectively. The mean BUT observed was 13.87 +/- 4.79 seconds; however, in 22 percent of cases the values of BUT were even less than the lowest values laid down by various workers, from the Western countries. Maximum dry spots were located in the temporal quadrant.