Purpose: Postoperative infections can be caused by a contaminated environment, unsterile equipment, contaminated surfaces, and infected personnel as well as contaminated disinfectants. In order to establish guidelines for microbiological monitoring, a detailed microbiological surveillance was carried out in an ophthalmic hospital. Method: Over a period of 21 months, we assessed environmental Bacteria Carrying Particle (BCP) load and surface samples weekly (n=276); the autoclaving system once a month and repeated whenever the process failed (n= 24); the air conditioning filters for fungal growth once in four months (n = 15), and the disinfectant solution for contamination once in two months (n = 10). Additionally, the personnel involved directly in surgery were screened for potential pathogens such as Staphylococcus aureus and β haemolytic streptococci. Result: On 14 (5.07%) occasions the environment in the operating rooms had a significant risk of airborne infections. Sterilisation of instruments in the autoclaves was unsatisfactory on 4 (16.66 %) occasions. Samples from the filters of the air-conditioning units yielded potentially pathogenic fungi on 3 (20%) occasions. Personnel sampling revealed that 5 (8.77%) individuals harboured β haemolytic Streptococci in the throat and 4 (7.01 %) harboured S. aureus in the nasal cavity. The samples of disinfectant in use were not contaminated. Conclusion: There is a need to standardise microbiological evaluation protocols for operating rooms.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed10359    
    Printed283    
    Emailed20    
    PDF Downloaded884    
    Comments [Add]    
    Cited by others 6    

Recommend this journal