Prevalence of plateau iris configuration in primary angle closure glaucoma using ultrasound biomicroscopy in the Indian population


1 Department of Ophthalmology, Glaucoma facility, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India
2 Department of Ophthalmology, Vision Eye Institute, Chatswood, Australia

Correspondence Address:
Tanuj Dada
Department of Ophthalmology, Dr. Rajendra Prasad Center for Ophthalmic Sciences, AIIMS, New Delhi - 110 029
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0301-4738.95865

Rights and Permissions

Purpose: To report the prevalence of plateau iris in patients with primary angle closure glaucoma (PACG), in North India. Materials and Methods: The patients with PACG, attending the glaucoma services at a tertiary care center in North India were included in the study. All patients had undergone Nd-YAG laser peripheral iridotomy at least four weeks prior to inclusion in the study. Four weeks prior to inclusion in the study, none of the patients had used pilocarpine. Ultrasound Biomicroscopy (UBM) images were qualitatively evaluated and plateau iris configuration was defined in an eye if the following criteria were fulfilled in two or more quadrants: anteriorly directed ciliary process supporting the peripheral iris, steep rise of iris root from its point of insertion followed by a downward angulation from the corneoscleral wall, absent ciliary sulcus, and iridotrabecular contact in the same quadrant. Results: One hundred and one eyes were included in the study. There were 63 (62.4%) females and 38 (37.6%) males. The mean age of the patients was 57.8 ± 9.5 years (range: 42 to 78 years). The mean axial length in the study population was 22.2 ± 1.1 mm. The mean spherical equivalent refraction was 0.06 ± 1.12 D. The mean intraocular pressure was 18.5 ± 4.7 mmHg (range: 12 - 24 mmHg). Twenty-nine (28.7%) subjects were diagnosed with plateau iris on the basis of above-defined criteria. Of the 29 eyes, 18 (62.1%) subjects had plateau iris in two quadrants, nine (31.03%) in three quadrants, and two (6.8%) had this configuration in all the four quadrants. Conclusions: Approximately 30% of the eyes with PACG had plateau iris on UBM. Plateau iris was very often the cause for residual angle closure following laser peripheral iridotomy in Indian eyes with PACG.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed4587    
    Printed89    
    Emailed7    
    PDF Downloaded541    
    Comments [Add]    
    Cited by others 1    

Recommend this journal