Surgical outcomes of inverted internal limiting membrane flap technique for large macular hole


Department of Vitreo-Retina, Sankara Eye Care Institutions, Coimbatore, Tamil Nadu, India

Correspondence Address:
Prabhushanker Mahalingam
Sankara Eye Centre, Sathy Road, Sivanandapuram, Coimbatore, Tamil Nadu
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0301-4738.121090

Rights and Permissions

We are presenting the initial results of inverted internal limiting membrane (ILM) flap technique for large macular hole. Five eyes of five patients with large diameter macular hole (>700 μm) were selected. All patients underwent inverted ILM flap technique for macular hole. Anatomical closure and functional success were achieved in all patients. There was no loss of best-corrected visual acuity in any of the patients. Inverted ILM flap technique in macular hole surgery seems to have a better hole closure rates, especially in large diameter macular holes. Larger case series is required to assess the efficacy and safety of this technique.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2224    
    Printed38    
    Emailed2    
    PDF Downloaded318    
    Comments [Add]    
    Cited by others 1    

Recommend this journal