Glyxambi
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
  • Users Online: 4323
  • Home
  • Print this page
  • Email this page

   Table of Contents      
BRIEF COMMUNICATION
Year : 2013  |  Volume : 61  |  Issue : 10  |  Page : 608-611

Beyond photography: Evaluation of the consumer digital camera to identify strabismus and anisometropia by analyzing the Bruckner's reflex


Institute of Ophthalmology, JN Medical College, Aligarh Muslim University, Aligarh, Uttar Pradesh, India

Date of Submission28-Sep-2011
Date of Acceptance17-Apr-2012
Date of Web Publication7-Nov-2013

Correspondence Address:
Abadan K Amitava
Institute of Ophthalmology, JN Medical College, Aligarh Muslim University, Aligarh, Uttar Pradesh
India
Login to access the Email id

Source of Support: Canon TX1 was procured by the AMUIO to support this research., Conflict of Interest: None


DOI: 10.4103/0301-4738.121092

Rights and Permissions
  Abstract 

Amblyopia screening is often either costly or laborious. We evaluated the Canon Powershot TX1 (CPTX1) digital camera as an efficient screener for amblyogenic risk factors (ARF). We included 138 subjects: 84-amblyopes and 54-normal. With the red-eye-reduction feature off, we obtained Bruckner reflex photographs of different sized crescents which suggested anisometropia, while asymmetrical brightness indicated strabismus; symmetry implied normalcy. Eight sets of randomly arranged 138 photographs were made. After training, 8 personnel, marked each as normal or abnormal. Of the 84 amblyopes, 42 were strabismus alone (SA), 36 had anisometropia alone (AA) while six were mixed amblyopes (MA). Overall mean sensitivity for amblyopes was 0.86 (95% CI: 0.83-0.89) and specificity 0.85 (95% CI: 0.77-0.93). Sub-group analyses on SA, AA and MA returned sensitivities of 0.86, 0.89 and 0.69, while specificities were 0.85 for all three. Overall Cohen's Kappa was 0.66 (95% CI: 0.62-0.71). The CPTX1 appears to be a feasible option to screen for ARF, although results need to be validated on appropriate age groups.

Keywords: Amblyopia, anisometropia, digital camera, photoscreening, strabismus


How to cite this article:
Bani SA, Amitava AK, Sharma R, Danish A. Beyond photography: Evaluation of the consumer digital camera to identify strabismus and anisometropia by analyzing the Bruckner's reflex. Indian J Ophthalmol 2013;61:608-11

How to cite this URL:
Bani SA, Amitava AK, Sharma R, Danish A. Beyond photography: Evaluation of the consumer digital camera to identify strabismus and anisometropia by analyzing the Bruckner's reflex. Indian J Ophthalmol [serial online] 2013 [cited 2019 Oct 23];61:608-11. Available from: http://www.ijo.in/text.asp?2013/61/10/608/121092


  Introduction Top


Amblyopia is mainly due to childhood strabismus and anisometropia, [1] and risks the possibility of bilateral impairment if trauma or adult eye conditions impact the better eye, [2] It is often preventable or reversible with appropriate timely interventions, [3] and thus remains a focus of screening. High end photo-screeners are not in widespread use due to costs, while simpler techniques are time consuming, labor intensive and require efficiency. [4]

Any useful screening test should be simple, safe, precise, acceptable, affordable, portable and efficient. Such advantages accrue by utilizing the Bruckner's reflex, with the retinoscope and the consumer digital cameras (CDC). [5],[6],[7],[8] The enhanced Bruckner reflex, visible from the top or side of the ophthalmoscope, [9] generates a light crescent in the pupil of an ametropic eye, while an uniformly brighter reflex is seen from the strabismic eye. The child friendly CDC records this, permitting both anisometropia and strabismus to be identified.

We used the Canon Powershot-TX1 (CP-TX1), as recommended by the lead author of the Alaskan study [8] (personal communication) [Figure 1], to assess its capability in identifying amblyogenic risk factors (ARF), namely strabismus and anisometropia, by evaluating its performance on a co-operative clinic population of amblyopes and normals.
Figure 1: The Canon Powershot TX1 (CP-TX1) digital camera used in the study

Click here to view



  Materials and Methods Top


After Institutional Review Board (IRB) approval, and informed consent, we included amblyopes with good bilateral red reflexes on ophthalmoscopy and excluded those who were too young to cooperate, unwilling to participate and pseudophakes. Amblyopes were patients having either anisometropia or strabismus, with a difference in best corrected visual acuity (BCVA) of ≥ 2 lines-Snellen, and no other organic pathology. Pre-cycloplegia, they were photographed from five feet, seated on a chair, in primary gaze, in a dim room (rheostat controlled, such that newsprint could be read with difficulty). With the aid of the 10 × optical zoom, flash photographs with bilateral red reflexes were recorded.

In addition, normal controls, without significant ametropia, having 20/20 Snellen Visual acuity (VA), and either orthotropia or mild-moderate phoria, demonstrating good recovery on cover test, and stereopsis of <100 arc seconds, were also similarly photographed. After a detailed work up, patients were grouped as: Strabismic-alone amblyopes (SA: without any significant anisometropia (<0.5 D), Anisometropic-alone amblyopes (AA: Anisometropia ≥0.5 D, and no strabismus) and Mixed amblyopes (MA: Having both strabismus and anisometropia).

The photographs were transferred to a laptop, cropped and coded. Eight compact discs (CDs) were made, with randomly arranged photographs. A separate instructional CD of 12 photographs, four each of controls, strabismics and anisometropes, helped train the raters: 'Normal' response if bilaterally the red glow appeared uniform and symmetrical [Figure 2]a. All others were 'abnormal' [Figure 2] b-d]; whether hyperopic (visible superior crescents), or myopic (visible inferior crescents); a difference in inter-ocular brightness suggested strabismus.
Figure 2: (a) Symmetrical red glow of both eyes suggestive of straight eyed emmetropia (normal). (b) Upper crescents, larger in the left eye: interpretation is anisometropia (hyperopic): Actual refraction: RE: +3 D + 0.5 DC × 180, LE: +4.5 D + 0.5 DC × 180. (c) Inferior crescents, larger in the left eye: interpretation is anisometropia (myopic): RE: -3.0 D; LE: -4.5 D. (d) Brighter red refl ex in the right eye, indicative of an ocular deviation; suggests a strabismus (RET 30 PD)

Click here to view


Eight medical, paramedical personnel, randomly selected from the department analyzed the CDs after the instructional CD had been repeatedly presented, altering the order till they correctly categorized at least 10 of the 12 snaps.


  Statistical Analyses Top


We used Statistical Package for the Social Sciences (SPSS) (V-12) and JavaStat to calculate diagnostic indices (95% CI) and compared inter-rater agreement with Cohen's Kappa.


  Results Top


We included photographs of 138 subjects, 85 (61%) males; baseline characteristics are shown in [Table 1]. There were 48 amblyopes with strabismus: 42 SA, and 6 MA, of these 48, 24 (50%) had esotropia (ET), 23 (48%) had exotropia (XT) and one, a vertical tropia. Mean (SD) strabismus at distance was 40.71 (22.54) prism diopter (PD) and at near 41.67 (22.26) PD. There were 36 AA; 22 (61.1%) had anisometropia between 1-2 D, and 14 had >2 D. For analyses, the amblyopes were re-categorized into six groups [Table 2] and compared with normals (n = 54). The summary of diagnostic indices (95% CI) of the raters and Cohen's kappa were calculated.
Table 1: Descriptive characteristics (mean (SD) and median (range)) of all the subjects (n=138): amblyopes (n=84) and normals (n=54)

Click here to view
Table 2: Summary statistics of diagnostic indices: mean (95% CI) values of eight raters, analyzed group wise (see text) Vs normals (n=54)

Click here to view



  Discussion Top


Our study using the CP-TX1, even with subgroup analyses, returned diagnostic indices around 80% [Table 2]. It is important to remember that most of the studies evaluating/screening either amblyogenic conditions or refractive errors have been done on younger and more appropriate age groups; while we had set out to evaluate the performance of the CDC to detect strabismus and anisometropia per se: Appropriate age group analyses would be planned subsequently if this analyses yielded encouraging results.

Despite extensive literature, studies differ widely with respect to the personnel performing screening, age when screened, tests utilized and the referral criteria, thus making comparisons challenging.

With VA tests, a study has shown significant better performance (P = 0.0001) of the Glasgow Acuity Cards (sensitivity 100%) compared to Sherridan Gardiner test (sensitivity 74%), [10] while another using the latter yielded high negative predictive value (NPV) (99-100%). [11] Lea Symbols and HOTV have produced amblyopia detection sensitivities of 0.65 (95% CI: 0.54-0.76) and 0.52 (95%CI: 0.42-0.63) with specificity fixed at (SFA) 94%. [12],[13]

Cover test for detecting strabismus returned sensitivity of 75% (95%CI: 57.7-89.9) and specificity of 100%. [14] With SFA 94%, the cover-uncover test yielded a sensitivity of 27% (95%CI: 17-37). [13]

The Polaroid suppression test (PST) to detect amblyopia yielded sensitivity of 96.2%, specificity of 41.1%, [15] and is thus no longer being used in the UK. The Worth 4-dot test has returned sensitivity of 91.6% and specificity of 96.3%. [16]

The Random dot E (RDE) stereo-test scored sensitivity of 54% and specificity of 87% when tested on children referred due to a one-line difference on VA testing. [17] The VIP Study group reported sensitivities of RDE and Stereo Smile as 0.63 and 0.77 for amblyopia with SFA 90%, and lower values of 0.28 and 0.61 respectively, with SFA 94%, [13] and sensitivities of non cycloplegic retinoscopy (NCR) for amblyopia as 0.85 (SFA 90%) and 0.88 (SFA 94%). [12],[13]

A study using the Otago photo-screener for ARF found a sensitivity of 81% and specificity of 98%. [18] Ottar, using the Medical Technology and Innovation (MTI) photo-screener reported sensitivity of 81.8% and specificity of 90.6%, while stating that it detected all cases of strabismus. [19] On the same data- set, Donahue et al. reported the sensitivity for detecting anisometropia, as low as 46% for +1.25 D, subsequently improving to 48% for + 1.5 D, 81% for +2.0 D and 100% for ≥2.5 D. [20] Hatch's study yielded lower sensitivities (54% and 53%: Due to differing referral criteria) and specificities (87% and 91%) with the MTI photo-screener. [21] Barry and Konig used the Retinomax NCR to screen for amblyogenic anisometropia and reported sensitivity and specificity of 80% and 58% for >1.5 DC or > 1 D anisometropia, and 70% and 60% for 2.0 DC or 1.5 D anisometropia. [22] The vision in preschoolers (VIP) Study group using the Retinomax reported a sensitivity of 85% (SFA 90%) and 77% (95%CI: 67-87) with SFA 94%. [13] In addition the VIP Study group also provided sensitivities for amblyopia screening of 80% and 57% (95% CI: 47-67) for Power Refractor, 62% and 62% (95% CI: 52-72) for IScreen Photo-screener and 89% and 80% (95% CI: 72-88) for Sure Sight Vision Screener with SFA 90% and 94% respectively. [12],[13]

On comparison with the Brückner test performed by pediatric residents, our data compares favorably: Our sensitivity of 86% vs 61% for pediatric residents, and specificity of 85% vs 71%. [19] Our figures are comparable to those of Kothari to detect ARF with the Brückner test: Our sensitivity of 86% vs. 87.5% and specificity of 85% Vs. 84.1%. [7] Amitava evaluating the modified Brückner test (MBT) using the streak retinoscope, [5] (on children who failed 6/9 Snellen) has reported the sensitivity and specificity as follows: 57% and 97% for anisometropia of 0.5 D; 74% and 95% for anisometropia of 1 D, and 50% and 98% for strabismus and concluded that MBT is accurate and useful for ruling them. Considering the high specificity obtained in our study, it is likely that the CDC method is equally effective.

Importantly, our study appears to have a good inter-rater agreement evident from a 66% (95% CI: 61 to 70) Cohen's Kappa statistic right across sub-groups and raters [Table 2]. [23]


  Conclusion Top


Our study provides evidence with a suitable CDC, one may effectively screen for ARFs, even if it needs validation in appropriate age groups. In all likelihood, results should be similar since sensitivity and specificity are test related characteristics and do not alter with prevalence. CDCs offer an attractive alternative for amblyopia screening, with a universal applicability appropriate in a vast developing country like ours.

 
  References Top

1.
Robaei D, Rose KA, Ojaimi E, Kifley A, Martin FJ, Mitchell P. Causes and associations of amblyopia in a population-based sample of 6-year-old Australian children. Arch Ophthalmol 2006;124:878-84.  Back to cited text no. 1
    
2.
Van Leeuwen R, Eijkemans MJ, Vingerling JR, Hofman A, de Jong PT, Simonsz HJ. Risk of bilateral visual impairment in individuals with amblyopia: The Rotterdam study. Br J Ophthalmol 2007;91:1450-1.  Back to cited text no. 2
    
3.
Pediatric Eye Disease Investigator Group. A comparison of atropine and patching treatments for moderate amblyopia by patient age, cause of amblyopia, depth of amblyopia and other factors. Ophthalmology 2003;110:1632-7;discussion 1637-8.  Back to cited text no. 3
    
4.
Carlton J, Karnon J, Czoski-Murray C, Smith KJ, Marr J. The clinical effectiveness and cost-effectiveness of screening programmes for amblyopia and strabismus in children up to the age of 4-5 years: A systematic review and economic evaluation. Health Technol Assess 2008;12:11-194.  Back to cited text no. 4
    
5.
Amitava AK, Kewlani D, Khan Z, Razzak A. Assessment of a modification of Brückner's test as a screening modality for anisometropia and strabismus. Oman J Ophthalmol 2010;3:131-5.  Back to cited text no. 5
[PUBMED]  Medknow Journal  
6.
Lang D, Leman R, Arnold AW, Arnold RW. Validated por pediatric vision screening in the Alaska Bush: A VIPS-like study in the Koyukon. Alaska Med 2007;49:2-15.  Back to cited text no. 6
    
7.
Kothari MT, Turakhia JK, Vijayalakshmi P, Karthika A, Nirmalan PK. Can the Brückner test be used as a rapid screening test to detect amblyogenic factors in developing countries? Am Orthopt J 2003;53:121-6.  Back to cited text no. 7
    
8.
Arnold RW. Highly specific photoscreening at the Alaska State Fair.Valid Alaska blind child discovery photoscreening and interpretation. Alaska Med 2003;45:34-40.  Back to cited text no. 8
    
9.
Arnold RW. Vision screening in Alaska: Experience with enhanced Brückner test. Alaska Med 1993;35:204-8.  Back to cited text no. 9
    
10.
Simmers AJ, Gray LS, Spowart K. Screening for amblyopia: A comparison of pediatric letter tests. Br J Ophthalmol 1997;81:465-9.  Back to cited text no. 10
    
11.
Newman DK, East MM. Preschool vision screening: Negative predictive value for amblyopia. Br J Ophthalmol 1999;83:678-9.  Back to cited text no. 11
    
12.
Schmidt P, Maguire P, Dobson V, Quinn G, Ciner E, Cyert L, et al. Comparison of preschool vision screening test as administered by licensed eye care professionals in Vision in preschoolers study. Ophthalmology 2004;111:637-50.  Back to cited text no. 12
    
13.
Ying GS, Kulp MT, Maguire M, Ciner F, Cyert L, Schimdt P, et al. Sensitivity of screening tests in detecting vision in preschoolers-targeted vision disorders when specificity is set at 94%. Optom Vis Sci 2005;82:432-8.  Back to cited text no. 13
    
14.
Williams C, Harrad RA, Harvey I, Sparrow JM. ALSPAC Study Team. Screening for amblyopia in preschool children: Results of a population-based, randomized controlled trial. Ophthalmic Epidemiol 2001;8:279-95.  Back to cited text no. 14
    
15.
Pott JW, Kingma C, Verhoeff K, Grootendorst RJ, de Feber JT. The Polaroid suppression test in pediatric population with ophthalmologic disorders. J AAPOS 2003;7:137-41.  Back to cited text no. 15
    
16.
Morale SE, Jeffery BG, Fawcett SL, Stager DR, Salomao SR, Berezovsky A, et al. Preschool worth 4 shape test: Testability, reliability, validity. J AAPOS 2002;6:247-51.  Back to cited text no. 16
    
17.
Ruttum MS, Nelson DB, Stereopsis testing to reduce over referral in preschool vision screening. J Pediatr Ophthalmol Strabismus 1991;28:131-3.  Back to cited text no. 17
    
18.
Kennedy R, Sheps SB, Begeric D. Field trial of Otago photoscreeners. Can J Ophthalmol 1995;30:193-7.  Back to cited text no. 18
    
19.
Ottar WL, Scott WE, Holgado SI. Photoscreening for amblyogenic factors. J Pediatr Ophthalmol Strabismus 1995;32:289-95.  Back to cited text no. 19
    
20.
Donahue SP, Johnson TP, Ottar W, Scott WE. Sensitivity of photoscreeners to detect high magnitude amblyogenic factors. J AAPOS 2002;6:86-91.  Back to cited text no. 20
    
21.
Hatch SW, Tibbles CD, Mestito IR, Read R, Traveis L, Richman J. Validity and reliability of MTI Photoscreeners. Optom Vis Sci 1997;74:859-64.  Back to cited text no. 21
    
22.
Barry JC, Konig HH. Non-cycloplegic screening of amblyopia via refractive findings with the Nikon Retinomax hand held autorefracter in 3 year old kindergarten child. Br J Ophthalmol 2001;85:1179-82.  Back to cited text no. 22
    
23.
Fleiss JL. Statistical methods for rates and proportions. 2 nd ed. New York: John Wiley; 1981.  Back to cited text no. 23
    


    Figures

  [Figure 1], [Figure 2]
 
 
    Tables

  [Table 1], [Table 2]


This article has been cited by
1 Photorefraction of the Eye
Giuseppe Colicchia,Hartmut Wiesner,Dean Zollman
The Physics Teacher. 2015; 53(2): 103
[Pubmed] | [DOI]



 

Top
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
Abstract
Introduction
Materials and Me...
Statistical Analyses
Results
Discussion
Conclusion
References
Article Figures
Article Tables

 Article Access Statistics
    Viewed4435    
    Printed16    
    Emailed1    
    PDF Downloaded209    
    Comments [Add]    
    Cited by others 1    

Recommend this journal