ORIGINAL ARTICLE
Year : 2013  |  Volume : 61  |  Issue : 1  |  Page : 23-27

Our experience of fibrin sealant-assisted implantation of Ahmed glaucoma valve


1 Department of Glaucoma, Jadhavbhai Nathamal Singhvi, Medical Research Foundation, Sankara Nethralaya, Chennai, India
2 Dr. G. Sitalakshmi Memorial Clinic for Ocular Surface Disorders, Medical Research Foundation, Sankara Nethralaya, Chennai, India

Correspondence Address:
Nikhil S Choudhari
Medical Research Foundation, Sankara Nethralaya, 18, College Road, Chennai-600 006
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0301-4738.99976

Rights and Permissions

Aim: To report our experience with the fibrin sealant as a suture substitute for securing the human scleral patch graft during implantation of Ahmed glaucoma valve (AGV). Materials and Methods: A retrospective, non-comparative study of 12 eyes of 12 patients who underwent an AGV implantation with fibrin sealant for part of the procedure during June 2009 to September 2010. Results: The mean patient age was 21.5 ± 20.6 years. Male: Female ratio was 2 : 1. Seven (58.3%) patients were monocular. The indications for AGV were varied. The mean number of intra-ocular surgeries prior to an implantation of AGV was 1.8. The mean follow-up duration was 24.5 ± 17.9 weeks. There was a statistically significant reduction in the mean IOP and in the mean number of anti-glaucoma medications at the final visit compared to the pre-operative values (P < 0.01, paired t test). Conjunctival retraction was seen in 1 (8.3%) case. The scleral patch graft was retracted posteriorly in another (8.3%) case. There was no case of AGV tube exposure, tube-cornea touch, or conjunctival erosion. Vision threatening complication viz. late post-operative rhegmatogenous retinal detachment, unlikely to be related to the use of the fibrin sealant, occurred in 2 (16.6%) eyes. Conclusion: The fibrin sealant offers the advantages of safety and convenience to the placement of a scleral patch graft during an AGV implantation.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed3620    
    Printed27    
    Emailed1    
    PDF Downloaded252    
    Comments [Add]    
    Cited by others 1    

Recommend this journal