Glyxambi
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
  • Users Online: 1798
  • Home
  • Print this page
  • Email this page

   Table of Contents      
LETTER TO THE EDITOR
Year : 2013  |  Volume : 61  |  Issue : 6  |  Page : 312-313

Authors' reply


1 Department of Glaucoma, Jadhavbhai Nathamal Singhvi, Chennai, India
2 Dr. G. Sitalakshmi Memorial Clinic for Ocular Surface Disorders, Medical Research Foundation, Sankara Nethralaya, Chennai, India

Date of Web Publication27-Jun-2013

Correspondence Address:
Nikhil S Choudhari
Medical Research Foundation, Sankara Nethralaya, 18, College Road, Chennai - 600 006
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


Rights and PermissionsRights and Permissions

How to cite this article:
Choudhari NS, Neog A, Sharma A, Iyer GK, Srinivasan B. Authors' reply. Indian J Ophthalmol 2013;61:312-3

How to cite this URL:
Choudhari NS, Neog A, Sharma A, Iyer GK, Srinivasan B. Authors' reply. Indian J Ophthalmol [serial online] 2013 [cited 2019 Dec 8];61:312-3. Available from: http://www.ijo.in/text.asp?2013/61/6/312/114135

Dear Editor,

We thank the authors of the letter for their interest in our article. [1] We also thank them for highlighting important issues to take the discussion at a higher level.

The outer diameter of the drainage tube of the Ahmed glaucoma valve (AGV) is 0.63mm. [2] Therefore, the width of the patch graft on either side of the tube is about 2mm. We could achieve good adhesion of the scleral patch graft by gently stroking it over the underlying tube and host sclera with a muscle hook after applying the components of the fibrin sealant between the surfaces. One may use a partial thickness scleral graft if the thickness of the latter is thought to be more or use a wider graft if so required.

Tube cornea touch and conjunctival erosion are related to the placement of the patch graft. [3] Posterior retraction of the scleral patch graft did occur in one eye. The complication is discussed in our article. [1]

As the fibrin sealant is made from human blood, it may carry a risk of transmitting infectious agents, e.g., viruses, despite viral inactivation techniques and theoretically, the  Creutzfeldt-Jakob disease More Details (CJD) agent. While no ocular infection has been attributed to the use of fibrin sealant, transmission of systemic parvovirus B19 infection by fibrin sealant has been reported. [4],[5] None of our patients had infection related to the use of the fibrin sealant.

Conjunctival closure by fibrin sealant requires mobile conjunctiva to limit post-operative retraction, which can overcome the tensile strength of the fibrin sealant, [6] especially with the movement of eyelids. Most of our patients had undergone at least one conjunctival manipulating surgery with resultant significant conjunctival fibrosis. Therefore, we did not use fibrin sealant to close the conjunctival wound during AGV implantation.

The implant drainage tube or the base plate may erode into the globe through the underlying thinned host sclera in staphylomatous eyes. We do staphyloma repair, when indicated prior to implantation of AGV in intractable glaucoma.

The fibrin sealant can be prepared side by side by an assistant as the surgery is being performed. The globe is hypotonous when the anchoring sutures to the scleral patch graft are taken and a safe suturing may be time consuming. We therefore, felt that the fibrin sealant-assisted placement of the scleral patch graft may reduce the overall surgical time. We do agree on the issue of increase in the cost of AGV implantation with the use of fibrin sealant. Nevertheless, we have suggested measures to reduce the per-patient-price of the fibrin sealant in the article. [1]

 
  References Top

1.
Choudhari NS, Neog A, Sharma A, Iyer GK, Srinivasan B. Our experience of fibrin-sealant-assisted implantation of Ahmed glaucoma valve. Indian J Ophthalmol 2013;61:23-7.  Back to cited text no. 1
[PUBMED]  Medknow Journal  
2.
Ahmed glaucoma valve® [package insert]. Rancho, CA: New World Medical, Inc; 2013.  Back to cited text no. 2
    
3.
Freedman J. Scleral patch grafts with Molteno setons. Ophthalmic Surg 1987;18:532-4.  Back to cited text no. 3
[PUBMED]    
4.
Kawamura M, Sawafuji M, Watanabe M, Horinouchi H, Kobayashi K. Frequency of transmission of human parvovirus B19 infection by fibrin sealant used during thoracic surgery. Ann Thorac Surg 2002;73:1098-100.   Back to cited text no. 4
[PUBMED]    
5.
Hino M, Ishiko O, Honda KI, Yamane T, Ohta K, Takubo T, et al. Transmission of symptomatic parvovirus B19 infection by fibrin sealant used during surgery. Br J Haematol 2000;108:194-5.   Back to cited text no. 5
[PUBMED]    
6.
Kahook MY, Noecker RJ. Fibrin glue-assisted glaucoma drainage device surgery. Br J Ophthalmol 2006;90:1486-9.  Back to cited text no. 6
[PUBMED]    




 

Top
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
References

 Article Access Statistics
    Viewed811    
    Printed16    
    Emailed0    
    PDF Downloaded82    
    Comments [Add]    

Recommend this journal