• Users Online: 47244
  • Home
  • Print this page
  • Email this page

   Table of Contents      
LETTER TO THE EDITOR
Year : 2013  |  Volume : 61  |  Issue : 9  |  Page : 534

Factors having implications on re-retinal detachments after silicone oil removal


Retina Foundation and Asopalav eye Hospital, Shahibaug, Ahemedabad, India

Date of Web Publication8-Oct-2013

Correspondence Address:
Manish P Nagpal
Retina Foundation and Asopalav Eye Hospital, Near Shahibaug Underbridge, Shahibaug, Ahmedabad, Gujarat
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0301-4738.119463

Rights and Permissions

How to cite this article:
Nagpal MP, Videkar RP, Nagpal KM. Factors having implications on re-retinal detachments after silicone oil removal. Indian J Ophthalmol 2013;61:534

How to cite this URL:
Nagpal MP, Videkar RP, Nagpal KM. Factors having implications on re-retinal detachments after silicone oil removal. Indian J Ophthalmol [serial online] 2013 [cited 2024 Mar 28];61:534. Available from: https://journals.lww.com/ijo/pages/default.aspx/text.asp?2013/61/9/534/119463

Dear Editor,

We thank the readers for their interest and valuable comments in response to our article. We agree with the reader that two-port approach for silicone oil removal is less invasive, but hardly gives any control to the surgeon over evaluating the retinal status during the procedure. Sometimes a retinal detachment is encountered intraoperatively after silicone oil removal due to a pre-existing hidden break or reopening of the pre-existing break, [1] which until then was/were tamponade by silicone oil. We follow the three-port approach so as to tackle such an eventuality in addition to the obvious indication of laser augmentation or epiretinal membrane removal as suggested by the reader. The small gauge vitrectomy systems further reduce the chances of conjunctival scarring and can hardly be called invasive and we strongly recommend use of a three-port vitrectomy for oil removal instead of a two-port, which gives the surgeon very little on table control over checking the retinal status and can take corrective measure if required.

This study which was aimed at studying the relation between retinal re-detachment following silicone oil removal and its relation with the encirclage, laser retinopexy, duration of tamponade, emulsification of silicone oil and hence the reasons of retinal detachment such as opening of retinal break due to proliferative vitreoretinopathy (PVR) and instrument touch was out of the scope of the study. PVR is anyways present in most cases where silicon oil is injected and is an important factor anyways for any sort of recurrence of re-detachment whatsoever. We do agree that for studying the reasons of retinal detachment due to various variables a broader randomised trial would be required.

We agree with the reader that difference in densities of silicone oil can affect the results and would like to congratulate the reader for their excellent observation; however, we would like to clarify that we had used only 1000 centistokes of silicone oil in all the cases. We have addressed this issue in our review article on silicone oil removal. [2]

It is an excellent suggestion to compare the average duration of oil removal in emulsified and no emulsified group and we would be happy to look at that aspect in a future study.

 
  References Top

1.
Hutton WL, Azen SP, Blumkranz MS, Lai MY, McCuen BW, Han DP, et al. The effects of silicone oil removal. Silicone study report 6. Arch Ophthalmol 1994;112:778-85.  Back to cited text no. 1
    
2.
Nagpal M, Videkar R. Silicone oil Removal. Expert Rev Ophthalmol 2012;7:87-96.  Back to cited text no. 2
    



This article has been cited by
1 Macular changes after primary retinectomy for retinal detachment complicated by proliferative vitreoretinopathy
Piergiacomo Grassi, David Charteris
Clinical and Experimental Optometry. 2023; : 1
[Pubmed] | [DOI]
2 A Prediction Nomogram for Recurrent Retinal Detachment
Yongying Zhou, Qianyi Lu, Zhigang Chen, Peirong Lu
Risk Management and Healthcare Policy. 2023; Volume 16: 479
[Pubmed] | [DOI]
3 STRUCTURAL AND FUNCTIONAL MACULAR CHANGES AFTER RETINECTOMY FOR RETINAL DETACHMENT COMPLICATED BY PROLIFERATIVE VITREORETINOPATHY
Piergiacomo Grassi, Saffron Melville, Anu-Sree Hariprasad, Stephen Winder, Yashin Ramkissoon, Kurt Spiteri-Cornish, Raquel G. Cabrera, Siddharth Subramani, Anand Chawla
Retina. 2021; 41(12): 2531
[Pubmed] | [DOI]
4 Retinal electrophysiological changes related to early versus late silicone oil removal
Haitham Y. Al-Nashar, Sherif A. Dabbour, Mohammed A. Alnaimy
International Ophthalmology. 2021; 41(12): 4075
[Pubmed] | [DOI]
5 Management of recurrent rhegmatogenous retinal detachment
Manish Nagpal, Pranita Chaudhary, Shachi Wachasundar, Ahmed Eltayib, Aparajita Raihan
Indian Journal of Ophthalmology. 2018; 66(12): 1763
[Pubmed] | [DOI]



 

Top
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
References

 Article Access Statistics
    Viewed1491    
    Printed45    
    Emailed0    
    PDF Downloaded176    
    Comments [Add]    
    Cited by others 5    

Recommend this journal