Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
  • Users Online: 4313
  • Home
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2014  |  Volume : 62  |  Issue : 5  |  Page : 615-618

Influence of disc area on retinal nerve fiber layer thickness measurement by spectral domain optical coherence tomography


1 Department of Glaucoma, Vasan Eye Care, 8-1-5/7, Janak Plaza, Opp Clock Tower, SD Road, Secunderabad, Andhra Pradesh, India
2 Department of Biostatistics, National Institute Of Nutrition, Hyderabad, India
3 Pushpagiri Eye Institute, Secunderabad, Andhra Pradesh, India

Correspondence Address:
Tarannum Mansoori
Department of Glaucoma, Vasan Eye Care, 8-1-5/7, Janak Plaza, Opp. Clock Tower, SD Road, Secunderabad -500 003, Andhra Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0301-4738.121134

Rights and Permissions

Background: To examine the effect of optic disc area on peripapillary RNFLT (retinal nerve fiber layer thickness) measurement at circle diameter of 3.4 mm around optic nerve head using spectral OCT/SLO (Optical coherence tomography/scanning laser ophthalmoscope). Materials and Methods : In this prospective, cross sectional study, one hundred and two eyes of 102 normal subjects underwent RNFLT and disc area measurement using spectral OCT/SLO. Based on disc area, subjects were divided into three groups i.e., <3 mm2 (32 eyes), 3-4 mm2 (36 eyes) and >4 mm2 (34 eyes). The effect of disc area on RNFLT parameters was analyzed using linear regression analysis. Results: The mean and quadrant RNFLT did not show significant correlation with disc area in subjects with disc area of <4 mm2, however in eyes with disc area >4 mm2, average RNFLT, superior and temporal quadrant RNFLT showed negative correlation with disc area, which was statistically significant (P = 0.004, P = 0.005 and P = 0.002, respectively) Conclusion: In healthy eyes of disc area <4 mm2, disc size does not appear to affect peripapillary RNFLT measurement by spectral OCT/SLO. Average, superior and temporal quadrant RNFLT measurements were inversely proportional to disc area in eyes with disc area >4 mm2. Hence, RNFLT measurement by OCT in eyes with optic disc area of >4 mm2 should be interpreted carefully.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1344    
    Printed21    
    Emailed1    
    PDF Downloaded225    
    Comments [Add]    

Recommend this journal