Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
  • Users Online: 4394
  • Home
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2014  |  Volume : 62  |  Issue : 7  |  Page : 788-791

Personal A-constant in relation to axial length with various intraocular lenses


Department of Ophthalmology, Faculty of Medicine, Cairo University, Giza, Egypt

Correspondence Address:
Mohamed A Eldaly
Department of Ophthalmology, Cairo University Hospitals (Kasr ElAini), Al-Saray Street, El Manial, Cairo, Postal address: 11956
Egypt
Login to access the Email id

Source of Support: This research received no specific grant from any funding agency in the public, commercial or not-for-profit sectors., Conflict of Interest: None


DOI: 10.4103/0301-4738.138300

Rights and Permissions

Purpose: To study the relationship between the axial length and personal A-constant for the 1-piece Tecnis (Abbott ZCB00), AcrySof MA60AC (Alcon) and the Quatrix aspheric preloaded (CROMA) intraocular lenses (IOL). Materials and Methods: Patients matching the inclusion criteria were further subdivided according to the implanted IOL in this prospective comparative study. The obtained refractive outcomes were introduced into the formula installed in the biometry machine (Humphrey model 820 ultrasonic biometer) to obtain the personal A-constant for each eye. Polynomial regression analysis was done to study the individualized A-constant for each type of IOL in relation to preoperative axial length measurement. Results: Two hundred and forty five eyes of 186 patients were enrolled into this study, of whom 73 eyes with Tecnis 1-piece, 116 eyes with MA60AC, and 56 eyes with Quatrix. The median of personalized A-constant for Tecnis 1-piece, MA60AC, and Quatrix were 119.21 (SD 1.3, Std. Mean error 0.15), 119 (SD 1.2, Std. Mean error 0.11) and 120.4 (SD 1.2, Std. Mean error 0.16) respectively. Regression plots for the same range of axial length among all the groups showed that the Tecnis1 group followed the same pattern of the Quatrix group in which there was a linear relationship of a trend towards myopia when the axial length had increased and a hyperopic shift when decreased. This relationship changed into a plateau when the axial length became in the range of 23.5 mm to 27 mm in the MA60AC group. Conclusions: Personal A-constant follows different trends with different IOLs even for the same range of axial length.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2194    
    Printed17    
    Emailed0    
    PDF Downloaded207    
    Comments [Add]    

Recommend this journal