Year : 2015  |  Volume : 63  |  Issue : 11  |  Page : 815-820

A cross-sectional study to compare intraocular pressure measurement by sequential use of Goldman applanation tonometry, dynamic contour tonometry, ocular response analyzer, and Corvis ST


1 Department of Glaucoma, Narayana Nethralaya, Bengaluru, Karnataka, India
2 Department of Research, Narayana Nethralaya, Bengaluru, Karnataka, India
3 Department of Cornea and Refractive Surgery, Narayana Nethralaya, Bengaluru, Karnataka, India
4 Department of Imaging, Biomechanics and Mathematical Modeling Solutions Lab, Narayana Nethralaya, Bengaluru, Karnataka, India

Correspondence Address:
Sushma Tejwani
Glaucoma Services, Narayana Nethralaya, Narayana Health City, #258/A, Bommasandra, Hosur Road, Bengaluru - 560 099, Karnataka
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0301-4738.171956

Rights and Permissions

Objective: To study the correlation and effect of sequential measurement of intraocular pressure (IOP) with Goldmann applanation tonometer (GAT), ocular response analyzer (ORA), dynamic contour tonometer (DCT), and Corvis ST. Setting and Design: Observational cross-sectional series from the comprehensive clinic of a tertiary eye care center seen during December 2012. Methods: One hundred and twenty-five study eyes of 125 patients with normal IOP and biomechanical properties underwent IOP measurement on GAT, DCT, ORA, and Corvis ST; in four different sequences. Patients with high refractive errors, recent surgeries, glaucoma, and corneal disorders were excluded so as to rule out patients with evident altered corneal biomechanics. Statistical Analysis: Linear regression and Bland-Altman using MedCalc software. Results: Multivariate analysis of variance with repeated measures showed no influence of sequence of device use on IOP (P = 0.85). Linear regression r 2 between GAT and Corvis ST, Corvis ST and Goldmann-correlated IOP (IOPg), and DCT and Corvis ST were 0.37 (P = 0.675), 0.63 (P = 0.607), and 0.19 (P = 0.708), respectively. The Bland-Altman agreement of Corvis ST with GAT, corneal compensated IOP, and IOPg was 2 mmHg (−5.0 to + 10.3), −0.5 mmHg (−8.1 to 7.1), and 0.5 mmHg (−6.2 to 7.1), respectively. Intraclass correlation coefficient for repeatability ranged from 0.81 to 0.96. Conclusions: Correlation between Corvis ST and ORA was found to be good and not so with GAT. However, agreement between the devices was statistically insignificant, and no influence of sequence was observed.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed5379    
    Printed85    
    Emailed4    
    PDF Downloaded573    
    Comments [Add]    
    Cited by others 7    

Recommend this journal