Glyxambi
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
  • Users Online: 699
  • Home
  • Print this page
  • Email this page

   Table of Contents      
BRIEF COMMUNICATION
Year : 2015  |  Volume : 63  |  Issue : 1  |  Page : 69-70

Fundus imaging with a nasal endoscope


Department of Vitreo-retina and Ocular Oncology, Sankara Eye Hospital, Bengaluru, Karnataka, India

Date of Submission19-Feb-2014
Date of Acceptance18-Jun-2014
Date of Web Publication16-Feb-2015

Correspondence Address:
Rajesh Ramanjulu
Sankara Eye Hospital, Airport-Varthur Road, Kundanahalli Gate, Bengaluru - 560 037, Karnataka
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0301-4738.151479

Rights and Permissions
  Abstract 

Wide field fundus imaging is needed to diagnose, treat, and follow-up patients with retinal pathology. This is more applicable for pediatric patients as repeated evaluation is a challenge. The presently available imaging machines though provide high definition images, but carry the obvious disadvantages of either being costly or bulky or sometimes both, which limits its usage only to large centers. We hereby report a technique of fundus imaging using a nasal endoscope coupled with viscoelastic. A regular nasal endoscope with viscoelastic coupling was placed on the cornea to image the fundus of infants under general anesthesia. Wide angle fundus images of various fundus pathologies in infants could be obtained easily with readily available instruments and without the much financial investment for the institutes.

Keywords: Imaging, nasal endscope, paediatric fundus


How to cite this article:
Shanmugam P M, Ramanjulu R, Divyansh Mishra K C. Fundus imaging with a nasal endoscope. Indian J Ophthalmol 2015;63:69-70

How to cite this URL:
Shanmugam P M, Ramanjulu R, Divyansh Mishra K C. Fundus imaging with a nasal endoscope. Indian J Ophthalmol [serial online] 2015 [cited 2019 Dec 11];63:69-70. Available from: http://www.ijo.in/text.asp?2015/63/1/69/151479

Fundus photography in infants and children is essential when dealing with diseases such as retinoblastoma and retinopathy of prematurity (ROP). Posterior fundus images can be obtained in co-operative children with a regular fundus camera or the slit lamp mounted digital camera, albeit with some difficulty. [1] Infants under general anesthesia may be held up to the fundus camera to obtain fundus images, but this technique is fraught with risks.

Techniques such as custom mounting the fundus camera vertically, handheld fundus camera, video indirect ophthalmoscope, and the Retcam have been employed to image the fundi of children under general anesthesia. [2] We had recently described a technique of using a regular hand-held video camera for photographic and video documentation of posterior fundus lesions, particularly for use in infants under anesthesia. [3] We herein describe a technique of imaging the infant's fundus using a rigid nasal endoscope.


  Materials and Methods Top


Instrumentation

A regular nasal endoscope (Leone Nasal Endoscope, China, Costs 400 USD) can be used with a coupling agent like a viscoelastic gel.

Technique

The infant to be examined is administered general anesthesia after pupillary dilation. Adult fundus can also be imaged either in sitting/lying comfortably on the examination chair/couch. The nasal endoscope is applied to the cornea over a drop of viscoelastic gel. Care should be taken to avoid pressing on the cornea with the tip of the endoscope but to glide over the gel.

The endoscope light source illuminates the fundus allowing the video and still images to be displayed on the monitor and captured. Moving the endoscope to the periphery of the cornea and tilting it, allows visualization of the peripheral fundus and extreme periphery.


  Discussion Top


Fundus imaging of retinoblastoma is particularly essential to assess response to treatment and in serial follow-up. Wide field fundus imaging using a contact camera is being employed in lieu of fundus examination to screen for ROP in developing countries. The choice of fundus imaging system infants remains the RetCam . It offers wide field fundus imaging, facility to perform fluorescein angiography and portability but with the limitation of being costly.

A nasal endoscope is constructed with a cylindrical viewing system in the center and a fiber-optic light source encased around the viewing system. When applied on to the cornea, the light illuminates the fundus allowing image capture [Figure 1] [Figure 2] [Figure 3]. Being a contact viewing system, it allows wide-angle fundus imaging, and the narrow caliber of the endoscope allows using it to view the anterior chamber angle as well [Figure 4].
Figure 1: Posterior pole fundus photo obtained using the nasal endoscope

Click here to view
Figure 2: Nasal endoscope image of a partially regressed retinoblastoma along the superotemporal quadrant

Click here to view
Figure 3: Peripheral nasal endoscope fundus image showing multiple inactive vitreous seeds and partly regressed retinoblastoma

Click here to view
Figure 4: Nasal endoscope image of the angle

Click here to view


Limitations of the technique

Comparatively, the endoscope allows a narrower field (just short the equator in a single field) of fundus imaging in contrast to the RetCam . This is because of the narrow caliber of the endoscope. The long, thin, and cylindrical endoscope with a heavy camera mounted on the top and a fiber-optic light source [[Figure 5]a-b]. Attached to it can be a bit difficult to handle when in contact with the cornea. This can be mitigated with one person handling the tip of the endoscope in contact with the cornea while another supports the heavy camera part of it. If not properly placed reflexes from the corneal and lenticular surfaces may at times be troublesome.
Figure 5: (a) Picture of the endoscope, (b) Picture of the assembled endoscope with the light pipe attached and connected to the light source

Click here to view


Nasal endoscopes are used by oculoplastic surgeons in an eye hospital for the purpose of performing endonasal dacryocystorhinostomy. They are much less expensive than the current camera systems used for fundus imaging in infants. The technique of using it to image the fundus is simple and can be easily mastered. It offers an inexpensive technique to image an infant's fundus with reasonable quality.

 
  References Top

1.
Fogla R, Rao SK. Ophthalmic photography using a digital camera. Indian J Ophthalmol 2003;51:269-72.  Back to cited text no. 1
[PUBMED]  Medknow Journal  
2.
Kabo DJ, Parel JM. A vertical mount fundus camera. Am J Ophthalmol 1979;88:944-6.  Back to cited text no. 2
    
3.
Shanmugam MP. Video indirect ophthalmoscopy using a hand-held video camera. Indian J Ophthalmol 2011;59:53-5.  Back to cited text no. 3
[PUBMED]  Medknow Journal  


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5]



 

Top
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
Abstract
Materials and Me...
Discussion
References
Article Figures

 Article Access Statistics
    Viewed864    
    Printed15    
    Emailed2    
    PDF Downloaded158    
    Comments [Add]    

Recommend this journal