Considerations in the management of aphakia


1 B. B. Eye Foundation, AMRI Medical Centre, Kolkata, West Bengal; Eye Department, AMRI Medical Centre, Kolkata, West Bengal; Westbank Hospital, Howrah, West Bengal, India
2 Department of Ophthalmology, Poznan City Hospital, ul. Szwajcarska 3, 61-285, Poznan; Department of Ophthalmology, University of Warmia and Mazury, ul. Zolnierska 14C, Olsztyn, Poland

Date of Web Publication3-Jun-2015

Correspondence Address:
Dr. Somdutt Prasad
B. B. Eye Foundation, 2/5 Sukhsagar, Sarat Bose Road, Kolkata - 700 020, West Bengal
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0301-4738.158098

Rights and Permissions

How to cite this article:
Prasad S, Grzybowski A. Considerations in the management of aphakia. Indian J Ophthalmol 2015;63:358

How to cite this URL:
Prasad S, Grzybowski A. Considerations in the management of aphakia. Indian J Ophthalmol [serial online] 2015 [cited 2020 May 26];63:358. Available from: http://www.ijo.in/text.asp?2015/63/4/358/158098

Dear Editor,

Can et al. describe their modification of an ab interno technique of transscleral suturing of one-piece posterior chamber intraocular lenses (IOLs) by injecting the IOL implantation in the through a clear corneal incision. [1] We believe that discussion of their proposal highlights relevant issues.

The article does not mention the increasingly popular techniques of secondary IOL implantation in aphakia management, namely intrascleral sutureless haptic fixation (SSF) and iris-claw lenses. [2],[3]

Sutureless scleral fixation uses a three-piece lens, often implanted by injector and avoids the risk of suture breakage. Also, when the eye moves, it acquires kinetic energy from the muscles and attachments, and the energy is distributed to the internal fluids as it stops. Thus, pseudophakodonesis is the result of oscillations of the fluids in the anterior and posterior segment of the eye. In a scleral-fixated IOL suspended with the suture, there is more pseudophakodonesis, and this may lead to posterior segment complications in the long-term. This is seen by the incidence of retinal detachment (4.9%) and chronic macular edema (CME) (7.3%). [4] However, no significant retinal problems are seen in the follow-up of SSF techniques potentially because a large part of the haptic is buried in scleral tunnels in these techniques and so the IOL is inherently more stable and less prone to pseudophakodonesis.

The choice of IOL is of concern for two reasons. Firstly, a one-piece IOL with square cross-section of haptics is not suitable for placement in the sulcus as it can lead to future problems. Their bulky haptics is large and thick enough to contact the posteriori iris and were shown, when implanted into the sulcus to lead to pigment dispersion syndrome, secondary IOP elevation, recurrent iridocyclitis, and CME. [5] Also, a hydrophobic material is probably preferable in these eyes. In addition, the use of 10-0 prolene, because of the risk of breakage over years, has largely been replaced by 9-0 prolene to reduce the rate of late suture breakage. Polytetrafluoroethylene CV-8 (Gore-tex) is also being used off-label in place of 10-0 prolene and has very good longevity. Authors of the article [1] do not mention the rates of late suture breakage, which has been significant with all sutured scleral fixated techniques reported to-date with intermediate/long follow-up. The proposed fixation is two-point, and there is probably no argument why the risk of IOL tilt is less than that from any other two-point fixation of three-piece lenses. In addition, authors propose to leave the sutures subconjunctivally which is also a cause for concern. It is well accepted that in any scleral suture-fixation technique, a scleral flap, scleral pocket or patch graft to cover the external suture is required to protect the suture and prevent the external suture erosion.

 
  References Top

1.
Can E, Basaran R, Gul A, Birinci H. Scleral fixation of one piece intraocular lens by injector implantation. Indian J Ophthalmol 2014;62:857-60.  Back to cited text no. 1
[PUBMED]  Medknow Journal  
2.
Scharioth GB, Prasad S, Georgalas I, Tataru C, Pavlidis M. Intermediate results of sutureless intrascleral posterior chamber intraocular lens fixation. J Cataract Refract Surg 2010;36:254-9.  Back to cited text no. 2
    
3.
Güell JL, Verdaguer P, Elies D, Gris O, Manero F, Mateu-Figueras G, et al. Secondary iris-claw anterior chamber lens implantation in patients with aphakia without capsular support. Br J Ophthalmol 2014;98:658-63.  Back to cited text no. 3
    
4.
McAllister AS, Hirst LW. Visual outcomes and complications of scleral-fixated posterior chamber intraocular lenses. J Cataract Refract Surg 2011;37:1263-9.  Back to cited text no. 4
    
5.
Chang DF, Masket S, Miller KM, Braga-Mele R, Little BC, Mamalis N, et al. Complications of sulcus placement of single-piece acrylic intraocular lenses: Recommendations for backup IOL implantation following posterior capsule rupture. J Cataract Refract Surg 2009;35:1445-58.  Back to cited text no. 5
    




 

Top
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
References

 Article Access Statistics
    Viewed703    
    Printed9    
    Emailed0    
    PDF Downloaded165    
    Comments [Add]    

Recommend this journal