ORIGINAL ARTICLE
Year : 2016  |  Volume : 64  |  Issue : 3  |  Page : 191-200

A novel smartphone ophthalmic imaging adapter: User feasibility studies in Hyderabad, India


1 Department of Ophthalmology, Stanford University School of Medicine, Palo Alto, CA, USA
2 Cornea and Anterior Segment Service, L. V. Prasad Eye Institute, Hyderabad, India
3 Smt. Kanuri Santhamma Center for Vitreoretinal Diseases, L. V. Prasad Eye Institute, Hyderabad, India
4 Department of Ophthalmology, Stanford University School of Medicine, Palo Alto, CA; Department of Ophthalmology, VA Palo Alto Health Care System, Palo Alto, CA, USA

Correspondence Address:
Dr. Robert T Chang
Stanford Byers Eye Institute, 2452 Watson Ct, MC 5353, Palo Alto, CA 94303
USA
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0301-4738.181742

Rights and Permissions

Aim of Study: To evaluate the ability of ancillary health staff to use a novel smartphone imaging adapter system (EyeGo, now known as Paxos Scope) to capture images of sufficient quality to exclude emergent eye findings. Secondary aims were to assess user and patient experiences during image acquisition, interuser reproducibility, and subjective image quality. Materials and Methods: The system captures images using a macro lens and an indirect ophthalmoscopy lens coupled with an iPhone 5S. We conducted a prospective cohort study of 229 consecutive patients presenting to L. V. Prasad Eye Institute, Hyderabad, India. Primary outcome measure was mean photographic quality (FOTO-ED study 1–5 scale, 5 best). 210 patients and eight users completed surveys assessing comfort and ease of use. For 46 patients, two users imaged the same patient's eyes sequentially. For 182 patients, photos taken with the EyeGo system were compared to images taken by existing clinic cameras: a BX 900 slit-lamp with a Canon EOS 40D Digital Camera and an FF 450 plus Fundus Camera with VISUPAC™ Digital Imaging System. Images were graded post hoc by a reviewer blinded to diagnosis. Results: Nine users acquired 719 useable images and 253 videos of 229 patients. Mean image quality was ≥ 4.0/5.0 (able to exclude subtle findings) for all users. 8/8 users and 189/210 patients surveyed were comfortable with the EyeGo device on a 5-point Likert scale. For 21 patients imaged with the anterior adapter by two users, a weighted κ of 0.597 (95% confidence interval: 0.389–0.806) indicated moderate reproducibility. High level of agreement between EyeGo and existing clinic cameras (92.6% anterior, 84.4% posterior) was found. Conclusion: The novel, ophthalmic imaging system is easily learned by ancillary eye care providers, well tolerated by patients, and captures high-quality images of eye findings.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed3094    
    Printed25    
    Emailed1    
    PDF Downloaded376    
    Comments [Add]    

Recommend this journal