  Abstract 

Purpose: To evaluate intraoperative complications during phacoemulsification of intumescent cataract using lens decompression technique. Methods: Participants with intumescent cataract scheduled for phacoemulsification were recruited and divided into two groups. In both groups, after the anterior capsule was stained with trypan blue, the anterior chamber was filled peripherally with a dispersive ophthalmic viscosurgical device (OVD) followed centrally by a higher viscosity cohesive OVD (Healon GV). In Group 2, a 25-gauge needle was then inserted into the lens center and liquid cortex aspirated by pulling back on the syringe plunger. The outcomes measured were the incidence of capsular radial tears and the incidence of conversion to extracapsular cataract extraction (ECCE). Results: In Group 1 (20 eyes), capsular radial tears occurred in four eyes, and in two eyes, the procedure had to be converted to ECCE. In Group 2 (20 eyes), no capsular radial tears or conversion to ECCE was reported. Conclusion: Lens decompression technique reduced the risk of capsular radial tears and conversion to ECCE during phacoemulsification of intumescent cataract.

Keywords: Intumescent cataract, lens decompression, liquefied cortex, phacoemulsification, radial capsular tear


How to cite this article:
Nabil KM. Lens decompression technique for prevention of intraoperative complications during phacoemulsification of intumescent cataract. Indian J Ophthalmol 2017;65:1436-9

How to cite this URL:
Nabil KM. Lens decompression technique for prevention of intraoperative complications during phacoemulsification of intumescent cataract. Indian J Ophthalmol [serial online] 2017 [cited 2024 Mar 29];65:1436-9. Available from: https://journals.lww.com/ijo/pages/default.aspx/text.asp?2017/65/12/1436/219845

Achieving a complete curvilinear capsulorhexis (CCC) of appropriate diameter is the cornerstone for a successful cataract surgery. Special care and attention are paid, even by experienced surgeons, when operating on eyes with intumescent cataract.[1]

Once the anterior capsule of the intumescent lens is perforated, the visibility, which was poor owing to absent red reflex, becomes even worse due to leakage of liquified cortical matter. The phenomenon that every cataract surgeon witnessed usually takes place within seconds of puncturing the anterior lens capsule when the elevated intralenticular pressure expands the initial capsule incision in an uncontrollable fashion, developing the Argentinean flag sign.[2]

Radial capsular tears may be limited to the anterior capsule, allowing careful phacoemulsification, or may necessitate conversion to extracapsular cataract extraction (ECCE) or may extend beyond the equator leading to more serious complications, such as zonular rupture, posterior capsule rupture, vitreous prolapse, nuclear drop, and posterior intraocular lens (IOL) dislocation.[3]

Several approaches have been described to minimize intraoperative complications when operating on intumescent cataracts, including the use of different types of ophthalmic viscosurgical devices (OVDs) or staining dyes.[2],[4] Other authors applied different endodiathermy devices to create a CCC in intumescent lenses.[5],[6],[7] Anterior capsule puncture with positive anterior chamber pressure and two-stage capsulorhexis have considerably reduced the complications of intumescent cataract surgery.[8] Other authors suggested that, instead of allowing the higher intralenticular pressure to passively equilibrate with the anterior chamber pressure, the pressure within the lens should be actively reduced by aspiration of liquefied cortical matter.[2],[9]

The present prospective study evaluated two surgical approaches and compared their intraoperative complications. In both groups, after the anterior capsule was stained with trypan blue, the anterior chamber was filled peripherally with a dispersive OVD followed centrally by a higher viscosity cohesive OVD, so the pressure in the anterior chamber was slightly higher than the intralenticular pressure. In Group 2, a 25-gauge needle was inserted into the lens center; liquid cortex was aspirated by pulling back on the syringe plunger, actively reducing intralenticular pressure.


  Methods Top


This case series study was carried out on patients with intumescent cataract [Figure 1]. Intumescent cataract diagnosis was based on lens swelling on slit-lamp examination and confirmed by ultrasound. Informed consent was obtained from all patients. All surgeries were performed by the same surgeon, the author, between October 2015 and November 2016.
Figure 1: Preoperative image of an intumescent cataract

Click here to view


Exclusion criteria included pseudoexfoliation syndrome, uncontrolled glaucoma, inadequate mydriasis (pupil diameter <6.0 mm), weak zonules, history of ocular trauma, and age <25 years. All patients were subjected to detailed ophthalmic examination using a BQ 900 slit lamp (Haag-Streit AG), axial length measurement using the OA-1000 optical biometer (Tomey Corporation; Nagoya, Japan), or A-scan ultrasound and corneal topography using Topographic Modeling System TMS-5 (Tomey Corporation; Nagoya, Japan). In the next step, the data were exported to OKULIX ray tracing software for IOL power calculation.

All surgeries were preceded by topical moxifloxacin hydrochloride 0.5% eye drops instilled every 2 h initiated 1 day preoperatively, complete asepsis, perioperative conjunctival sac sterilization with povidone–iodine 5%, topical anesthesia using tetracaine hydrochloride 1.0%, and pupil dilation.

In all eyes, a 2.5 mm clear corneal incision was tunneled at the limbus at 11 o'clock using Alcon steel blade keratome 2.5 mm (Alcon Laboratories; Ft Worth, TX, USA). Anterior capsule was stained with trypan blue (Visionblue Staining Solution, Dutch Ophthalmic, USA) under air [Figure 2]. The anterior chamber was filled peripherally with a dispersive OVD (Visicrom 2%, Croma-Pharma GmbH; Leobendorf, Austria) followed centrally by a higher viscosity cohesive OVD (Healon GV, Abbott Medical Optics Inc.,; Santa Ana, USA).

In Group 2, a 25-gauge needle was then introduced into the anterior chamber through the main incision, with the bevel down facing the anterior capsule. The needle was inserted into the lens center and liquid cortex aspirated by pulling back on the syringe plunger, aspirating 0.1–0.2 ml of liquefied cortex. No dry taps were encountered [Figure 3] and [Video 1].
Figure 2: Trypan blue staining of the anterior capsule

Click here to view
Figure 3: 25-gauge needle insertion into the lens, bevel down, under the anterior capsule, aspirating liquefied cortical matter

Click here to view





In all eyes, CCC was initiated using a bent 25-gauge needle through the main incision, then, the leaf of the opened anterior capsule was held using Koch capsulorhexis forceps (Geuder AG), and the capsulorhexis was continued circularly [Video 2]. Then, a self-sealing clear corneal stab incision was fashioned at the limbus at 2 o'clock position using Alcon steel blade superblade 15° (Alcon Laboratories; Ft Worth, TX, USA), and a second clear corneal self-sealing stab incision was created at the 10 o'clock position.




In both study groups, the stop and chop phacoemulsification technique was applied without hydrodissection or delineation using a 30° phaco tip using Alcon Infiniti system (Alcon Laboratories; Ft Worth, TX, USA), followed by removal of the remaining cortical matter through the side ports using bimanual irrigation/aspiration (I/A). Finally, the posterior capsule was polished.

In uneventful cases, a hydrophilic acrylic IOL (Aqua-Sense IOL, Ophthalmic Innovations International, OII) was inserted in the capsular bag using medium viscosity OVD to protect the corneal endothelium. After bimanual I/A of the OVD, stromal hydration of the incisions was performed and the eye patched. Postoperatively, topical moxifloxacin (0.5% Vigamox, Alcon) and corticosteroid (1% Econopred Plus, Alcon) were prescribed five times daily for 1 week, and nonsteroidal anti-inflammatory (0.1% Nevanac, Alcon) eye drops were prescribed three times daily for 1 week; then, corticosteroid and nonsteroidal anti-inflammatory eye drops were used alone for the following 3 weeks.

Statistical analysis

All descriptive statistical analyses were performed using IBM SPSS software (SPSS, Inc., version 20.0). Comparisons between groups for categorical variables were assessed using Chi-square test. The Kolmogorov–Smirnov test was used to verify the normality of distribution of variables. Student's t-test was used to compare the two groups for normally distributed quantitative variables. Significance of the obtained results was judged at the 5% level. P = 0.05 was considered statistically significant.


  Results Top


The 40 eyes of the studied participants were divided into two groups of 20 eyes each. In Group 1, the mean participant age was 66.9 years ± 3.1 (standard deviation [SD]) (ranging from 60 to 71 years), and in Group 2, it was 66.9 years ± 3.4 (SD) (ranging from 60 to 72 years). Group 1 included 9 males and 11 females while Group 2 included 8 males and 12 females. [Table 1] shows preoperative and intraoperative data in the two study groups.
Table 1: Comparison between the two studied groups according to different parameters

Click here to view


Radial capsular tears occurred in four eyes in Group 1 and were not encountered in Group 2. In uneventful cases in both groups, the capsulorhexis diameter averaged 5 mm, with no statistically significant difference between them. Two of the eyes with a radial capsular tear, endangering the equator, could not be managed by phacoemulsification, and the technique had to be converted to ECCE, with intracapsular IOL implantation, without posterior capsular rupture or vitreous loss.


  Discussion Top


This study compared two approaches to creating a CCC in patients with intumescent cataract and assessed the incidence of intraoperative complications in each technique. Intumescent cataract remains, even for more experienced surgeons, a surgical challenge owing to the absence of the red reflex and the high intralenticular pressure. Several recently published studies describe different measures that can be used to overcome these difficulties.

Several reports applied various types of dyes and OVDs [2],[3],[4],[10] while other studies made the use of diathermy or high-frequency diathermy for the creation of an anterior capsulotomy.[5],[6],[7],[11] Neodymium: YAG laser capsulotomy was applied to prevent extension of the capsular tear to the lens periphery in intumescent cataracts.[12],[13]

Gimbel [8] described a two-stage capsulorhexis technique which was initiated centrally and could be enlarged later to the intended size. Bhattacharjee et al.[14] initially released the intralenticular pressure after filling the anterior chamber with OVD and applied the high magnification of the operating microscope without capsule staining. Another applied an assisted slit illuminator mounted in the vicinity of the operating microscope to improve anterior capsule visualization and overcome the absence of the red reflex.[15]

Despite all studies and efforts to minimize intraoperative complications in intumescent cataract, the complication that might take place within seconds of puncturing of the anterior capsule is that the high intralenticular pressure expands the initial capsule incision in an uncontrolled way with the development of the Argentinean flag sign.[9] Therefore, instead of allowing the higher intralenticular pressure to passively equilibrate with the anterior chamber pressure, the pressure within the lens should be actively reduced by a closed system aspiration of liquefied cortical matter.

In the present study, in all eyes, the anterior capsule was stained with trypan blue to enhance visualization and reduce capsular elasticity. The complication rate was higher, though not statistically significant, in Group 1, which used peripherally dispersive OVD followed centrally by a higher viscosity cohesive OVD (Healon GV), than in Group 2, where lens decompression technique was applied. In Group 2, a 25-gauge needle was introduced into the anterior chamber through the main incision, with the bevel down, inserted into the lens center, and 0.1–0.2 ml of liquid cortex was aspirated by pulling back on the syringe plunger, actively reducing intralenticular pressure. The needle bevel was facing down to prevent aspiration of the anterior capsule into the needle, occluding it.

In all eyes in Group 2, active reduction of intralenticular pressure prevented the egress of liquefied cortical matter, protecting against the occurrence of radial capsular tears, allowed the completion of CCC, followed by uneventful stop and chop phacoemulsification technique and in the bag implantation of a foldable IOL. In group 1, radial capsular tears occurred in four eyes; in two of them, phacoemulsification was completed while in the other two cases, with radial capsular tears endangering the equator, the procedure had to be converted to ECCE with intracapsular IOL implantation, without posterior capsular rupture or vitreous loss.


  Conclusion Top


The lens decompression technique is reliable, safe, and more advantageous than the combined use of a dispersive and a higher viscosity cohesive OVD because it actively reduces intralenticular pressure by aspiration of liquefied cortical matter.

Further, larger group studies are recommended to confirm our findings and to investigate the role of femtosecond laser in intumescent cataract.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 
  References Top

1.
Hengerer FH, Dick HB, Kohnen T, Conrad-Hengerer I. Assessment of intraoperative complications in intumescent cataract surgery using 2 ophthalmic viscosurgical devices and trypan blue staining. J Cataract Refract Surg 2015;41:714-8.  Back to cited text no. 1
[PUBMED]    
2.
Figueiredo CG, Figueiredo J, Figueiredo GB. Brazilian technique for prevention of the argentinean flag sign in white cataract. J Cataract Refract Surg 2012;38:1531-6.  Back to cited text no. 2
[PUBMED]    
3.
Brazitikos PD, Tsinopoulos IT, Papadopoulos NT, Fotiadis K, Stangos NT. Ultrasonographic classification and phacoemulsification of white senile cataracts. Ophthalmology 1999;106:2178-83.  Back to cited text no. 3
[PUBMED]    
4.
Gavriş M, Popa D, Cărăuş C, Gusho E, Kantor E. Phacoemulsification in white cataract. Oftalmologia 2004;48:81-7.  Back to cited text no. 4
    
5.
Priglinger SG, Palanker D, Alge CS, Kreutzer TC, Haritoglou C, Grueterich M, et al. Pulsed electron avalanche knife: new technology for cataract surgery. Br J Ophthalmol 2007;91:949-54.  Back to cited text no. 5
[PUBMED]    
6.
Pham DT, Liekfeld A, Hartmann C. Capsulotomy in intumescent cataract with the high frequency diathermy capsulotom. Klin Monbl Augenheilkd 1998;212:29-31.  Back to cited text no. 6
[PUBMED]    
7.
Michalos P, Avila EN. “Capsulocopsis”: A new surgical instrument and method for capsulotomies. Ophthalmic Surg Lasers 1996;27:476-8.  Back to cited text no. 7
[PUBMED]    
8.
Gimbel HV. Two-stage capsulorhexis for endocapsular phacoemulsification. J Cataract Refract Surg 1990;16:246-9.  Back to cited text no. 8
[PUBMED]    
9.
Figueiredo CG, Figueiredo J, Figueiredo GB. Brazilian technique for prevention of the Argentinean flag sign in white cataract. J Cataract Refract Surg 2013;39:307.  Back to cited text no. 9
    
10.
Horiguchi M, Miyake K, Ohta I, Ito Y. Staining of the lens capsule for circular continuous capsulorrhexis in eyes with white cataract. Arch Ophthalmol 1998;116:535-7.  Back to cited text no. 10
[PUBMED]    
11.
Hausmann N, Richard G. Investigations on diathermy for anterior capsulotomy. Invest Ophthalmol Vis Sci 1991;32:2155-9.  Back to cited text no. 11
[PUBMED]    
12.
Richards JC, Harrison DC. Preoperative neodymium:YAG anterior capsulotomy in intumescent cataract: Preventing extension of the capsular tear to the lens periphery. J Cataract Refract Surg 2003;29:1630-1.  Back to cited text no. 12
[PUBMED]    
13.
Coelho RP, Martin LF, Paula JS, Scott IU. Comparison of preoperative Nd:YAG laser anterior capsulotomy versus two-stage curvilinear capsulorhexis in phacoemulsification of white intumescent cataracts. Ophthalmic Surg Lasers Imaging 2009;40:582-5.  Back to cited text no. 13
[PUBMED]    
14.
Bhattacharjee K, Bhattacharjee H, Goswami BJ, Sarma P. Capsulorhexis in intumescent cataract. J Cataract Refract Surg 1999;25:1045-7.  Back to cited text no. 14
[PUBMED]    
15.
Lee JE, Choi HY, Oum BS, Lee JS. Capsulorhexis assisted by slit illuminator for white cataract without a red reflex. Ophthalmic Surg Lasers Imaging 2007;38:349-52.  Back to cited text no. 15
[PUBMED]    


    Figures

  [Figure 1], [Figure 2], [Figure 3]
 
 
    Tables

  [Table 1]


This article has been cited by
1 Flow capsulorhexis: A novel technique in white and hypermature cataracts
Mithun Thulasidas, G Geetha
Indian Journal of Ophthalmology. 2024; 72(1): 73
[Pubmed] | [DOI]
2 Preventing the Argentinian flag sign and managing anterior capsular tears: A review
Stephen A LoBue, Allison E Rizzuti, Curtis R Martin, Sinan A Albear, Ekjyot S Gill, Christopher L Shelby, Wyche T Coleman, Edward F Smith
Indian Journal of Ophthalmology. 2024; 72(2): 162
[Pubmed] | [DOI]
3 Role of Preoperative Nd
Amit Champalal Porwal, Jitendra N. Jethani, Kavita A. Porwal, Meghna Shrishrimal, Parthvi R. Shah
Asia-Pacific Journal of Ophthalmology. 2021; Publish Ah
[Pubmed] | [DOI]
4 White Cataracts—Tips, Techniques and New Perspective
Luis Real
Current Ophthalmology Reports. 2020; 8(3): 93
[Pubmed] | [DOI]



 

Top
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
Abstract
Methods
Results
Discussion
Conclusion
References
Article Figures
Article Tables

 Article Access Statistics
    Viewed2460    
    Printed35    
    Emailed0    
    PDF Downloaded323    
    Comments [Add]    
    Cited by others 4    

Recommend this journal