Purpose: To compare the accuracy of manual and automated binarization technique for the analysis of choroidal vasculature. Methods: This retrospective study was performed on a total of 98 eyes of 60 healthy subjects. Fovea-centered swept source optical coherence tomography (SS-OCT) scans were obtained and choroidal area was binarized using manual and automated image binarization technique separately. Choroidal vessel visualization in the binarized scans were subjectively graded (grades 0–100) by comparing them with the original OCT scan images by two masked graders. The subjective variability and repeatability was compared between two binarization method groups. Intergrader and intragrader variability was estimated using paired t-test. The degree of agreement between the grades for each observer and between the observers was evaluated using Bland–Altman plot. Results: The mean accuracy grades of the automatically binarized images were significantly (P < 0.001) higher (93.38% ± 1.70%) than that of manually binarized images (78.06% ± 2.92%). There was a statistically significant variability and poor agreement between the mean interobserver grades in the manual binarization arm. Conclusion: Automated image binarization technique is faster and appears to be more accurate in comparison to the manual method.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed443    
    Printed0    
    Emailed0    
    PDF Downloaded113    
    Comments [Add]    

Recommend this journal