SURGICAL TECHNIQUE
Year : 2018  |  Volume : 66  |  Issue : 12  |  Page : 1849-1851

Bimanual 25-gauge chandelier technique for direct perfluorocarbon liquid-silicone oil exchange in retinal detachments associated with giant retinal tear


Shroff Eye Centre, New Delhi, India

Date of Submission23-Mar-2018
Date of Acceptance21-Aug-2018
Date of Web Publication19-Nov-2018

Correspondence Address:
Dr. Stuti Astir
Shroff Eye Centre, A.9, Kailash Colony, New Delhi - 110 048
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijo.IJO_440_18

Rights and Permissions
  Abstract 


Direct perfluorocarbon liquid (PFCL)-silicone oil exchange presents its own set of challenges in the micro incision vitreous surgery era. We propose a simple bimanual technique to circumvent this problem. Thirteen eyes of patients with retinal detachment associated with giant retinal tears underwent vitrectomy followed by self-retaining endo illuminator (Chandelier) assisted direct PFCL-silicone exchange. No intra or postoperative complications related to the surgical technique were noted. All patients had attached retinas and satisfactory visual recovery at 6 months. Direct bimanual PFCL silicone oil exchange using a Chandelier seems to be a safe and effective technique.

Keywords: Chandelier, giant tear retina, perfluorocarbon liquid, silicone oil


How to cite this article:
Astir S, Shroff DN, Gupta C, Shroff CM, Saha I, Dutta R. Bimanual 25-gauge chandelier technique for direct perfluorocarbon liquid-silicone oil exchange in retinal detachments associated with giant retinal tear. Indian J Ophthalmol 2018;66:1849-51

How to cite this URL:
Astir S, Shroff DN, Gupta C, Shroff CM, Saha I, Dutta R. Bimanual 25-gauge chandelier technique for direct perfluorocarbon liquid-silicone oil exchange in retinal detachments associated with giant retinal tear. Indian J Ophthalmol [serial online] 2018 [cited 2024 Mar 29];66:1849-51. Available from: https://journals.lww.com/ijo/pages/default.aspx/text.asp?2018/66/12/1849/245629



Giant retinal tears (GRTs) are defined as full-thickness circumferential tears of more than 90° of the retina associated with vitreous detachment.[1],[2],[3] Their management poses significant challenges owing to the many complications and technical difficulties. Best success rates of re-attachment and least chances of slippage of the GRT edge have been reported using silicone oil as tamponade.[4] Perfluorocarbon liquids (PFCLs) revolutionized the management of GRTs, and the advent of small gauge vitrectomy techniques have further optimized the treatment outcomes. Microincision vitreous surgery (MIVS) has been reported as a successful modality to treat these cases.[5] PFCL-silicone oil exchange using MIVS is challenging.

We included 13 patients with RD associated with GTR in our study. The extent of GTR ranged from 90° to 180°. In total, 23% (3 of 13) patients had 3 clock hours of GTR (90°) and 76.92% (10 of 13) had 6 clock hours of GTR (180°). Totally, 15% (2 of 13) patients had superior GTRs (10 o′clock to 1 o′clock) and 84.6% (11 of 13) patients had temporal GTRs (6 o′clock to 12 o′clock) [Figure 1]. None of the patients had inferior configuration of GTRs.
Figure 1: Representative preoperative fundus photograph showing a temporal GTR superotemporally. The GTR extended from 2 ′o clock to 5 ′o clock, however, the complete edge of the temporal GTR could not captured owing to peripheral location of the tear)

Click here to view



  Technique Top


We used a bimanual technique for direct PFCL-silicone oil exchange in 13 eyes of patients with retinal detachment with GTR. All the eyes underwent 25-gauge pars plana vitrectomy. After removal of the vitreous, PVR membranes, if present, were removed with an end-grasping forceps ensuring a traction free GRT edge. Base excision was done with depression. PFCL [perfluoro-n-octane (PFO)] (Auro octane; Aurolabs, Madurai, India) was used in all cases to flatten the retina [Figure 2].
Figure 2: Intraoperative photograph showing perfluorocarbon liquid bubble in situ. The temporal edge of the GTR is seen clearly in the photograph

Click here to view


After reattachment, four rows of confluent laser spots using a 25-gauge endophotocoagulation probe were applied around all GRTs as well as 360° [Figure 3]. A Chandelier (Alcon Fort Worth, TX) was inserted, the infusion cannula was clamped and direct PFCL-silicone oil exchange was done with flute needle in dominant hand and silicon oil injection in non-dominant hand. 1300-centistoke silicone oil (Aurosil; Aurolabs) was used for tamponade [Figure 4] and [Video 1].
Figure 3: Intraoperative picture showing settled retina with laser marks at edge of GTR

Click here to view
Figure 4: Representative picture showing chandelier assisted direct perfluorocarbon liquid-silicone oil exchange. Superiorly illumination provided by the chandelier is seen. The flute needle is kept in the dominant hand, and the tip is seen to be within the perfluorocarbon liquid bubble. The silicone oil is being injected into the eye through the other port and is seen entering the vitreous cavity above the perfluorocarbon liquid bubble

Click here to view





Postoperatively, the retina was attached in all eyes [Figure 5]. Preoperative Best Corrected Visual Acuity (BCVA) was 1.75+/–0.99. At 2 months, BCVA improved to 0.79+/–0.63 (P = 0.007). At 6 months, BCVA improved to 0.48+/–0.38 (P = 0.001). Two or more line improvement was seen in 76.9% patients at 6 months, 15.4% patients had stable vision and 7.7% showed two line worsening.
Figure 5: Postoperative picture showing well attached retina with silicon oil in situ (the GTR edge cannot be seen owing to peripheral location of the lasered tear)

Click here to view



  Discussion Top


With 20-gauge vitrectomy systems, silicone oil syringe was previously directly connected to the sutured infusion.[6]

In MIVS cases, where silicone oil is directly connected to the infusion,[7] the infusion line could slip out of the cannula owing to back-pressure exerted on the small gauge system. Current technique involves an assistant holding the syringe at site of infusion cannula after disconnecting the infusion line. However, the syringe could still slip out of the infusion, even with the assistant.

Direct exchange is surgeon-controlled without undue distortion of the globe (if syringe is held too tightly by an assistant), is quicker and leads to complete vitreous fill. In addition, no slippage of retinal tear or intra-ocular pressure (IOP) related issues were noted perioperatively. None of the cases required fluid air exchange (Indirect Exchange).

Disadvantages of this technique would include the additional cost incurred, along with complications related to making the fourth port. Inserting and moving an endoilluminator into the vitreous cavity could increase the risk of retinal tears related to sclerotomy site, lenticular damage, or posterior capsular tears.[8] Removal or movement of the Chandelier can rarely lead to hyphema due to bleed from sclerotomy site or hitting the root of iris. However, no complication was observed in our study.


  Conclusion Top


We conclude that direct PFCL-silicone oil exchange for RD with GTR seems to be a safe and effective technique with minimal intraoperative and postoperative complications.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
  References Top

1.
Schepens CL, Dobble JG, Mcmeel JW. Retinal detachments with giant breaks: Preliminary report. Trans Am Acad Ophthalmol Otolaryngol 1962;66:471-9.  Back to cited text no. 1
    
2.
Ang GS, Townend J, Lois N. Epidemiology of giant retinal tears in the United Kingdom: The British giant retinal tear epidemiology eye study (BGEES). Invest Ophthalmol Vis Sci 2010;51:4781-7.  Back to cited text no. 2
    
3.
Ghosh YK, Banerjee S, Savant V, Kotamarthi V, Benson MT, Scott RA, et al. Surgical treatment and outcome of patients with giant retinal tears. Eye (Lond) 2004;18:996-1000.  Back to cited text no. 3
    
4.
Dabour SA. The outcome of surgical management for giant retinal tear more than 180°. BMC Ophthalmol 2014;14:86.  Back to cited text no. 4
    
5.
Kumar V, Kumawat D, Bhari A, Chandra P. Twenty-five-gauge pars plana vitrectomy in complex retinal detachments associated with giant retinal tear. Retina 2018;38:670-7.  Back to cited text no. 5
    
6.
Han DP, Rychwalski PJ, Mieler WF, Abrams GW. Management of complex retinal detachment with combined relaxing retinotomy and intravitreal perfluoro-n-octane injection. Am J Ophthalmol 1994;118:24-32.  Back to cited text no. 6
    
7.
Barca F, Caporossi T, Rizzo S. Silicone oil: Different physical proprieties and clinical applications. Biomed Res Int 2014;2014:502143.  Back to cited text no. 7
    
8.
Kim KH, Sohn HJ, Song HJ, Lee DY, Nam DH. Surgeon-controlled-endoillumination-guided irrigation and aspiration during combined 23-gauge sutureless vitrectomy and cataract surgery in eyes with poor fundus reflex. J Cataract Refract Surg 2010;36:2028-31.  Back to cited text no. 8
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5]


This article has been cited by
1 Hybrid 23/25-Gauge Direct Perfluorocarbon Liquid—Silicone Oil Exchange
Abdelrahman M. Elhusseiny, Riley N. Sanders, Abdallah A. Ellabban, Ahmed B. Sallam
Retina. 2023; 43(12): 2123
[Pubmed] | [DOI]
2

Fully Automated Direct Perfluorocarbon Liquid-Silicone Oil Exchange

Kinza T Ahmad, Ahmed B Sallam, Ahmed A Saad, Abdallah A Ellabban
Clinical Ophthalmology. 2020; Volume 14: 4355
[Pubmed] | [DOI]
3 A rare case of intraocular communicating cysticercosis
RS Keerthhi Dhevi, V Anusha, MPrabhu Shanker, G Geetha
Indian Journal of Ophthalmology. 2020; 68(8): 1654
[Pubmed] | [DOI]



 

Top
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
Abstract
Technique
Discussion
Conclusion
References
Article Figures

 Article Access Statistics
    Viewed1835    
    Printed50    
    Emailed0    
    PDF Downloaded192    
    Comments [Add]    
    Cited by others 3    

Recommend this journal