• Users Online: 20153
  • Home
  • Print this page
  • Email this page

   Table of Contents      
LETTERS TO THE EDITOR
Year : 2018  |  Volume : 66  |  Issue : 3  |  Page : 478

Calibrated Bowman's lacrimal probe


Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India

Date of Web Publication26-Feb-2018

Correspondence Address:
Dr. Amar Pujari
Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Room No. 212, Second Floor, RPC-1, New Delhi - 110 029
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijo.IJO_1063_17

Rights and Permissions

How to cite this article:
Pujari A, Bajaj MS, Sharma P. Calibrated Bowman's lacrimal probe. Indian J Ophthalmol 2018;66:478

How to cite this URL:
Pujari A, Bajaj MS, Sharma P. Calibrated Bowman's lacrimal probe. Indian J Ophthalmol [serial online] 2018 [cited 2024 Mar 28];66:478. Available from: https://journals.lww.com/ijo/pages/default.aspx/text.asp?2018/66/3/478/226092



Dear Sir,

Epiphora due to the nasolacrimal duct and canalicular obstruction is a commonly encountered clinical problem by every ophthalmologist in their day-to-day practice. Assessment of level of lacrimal system blockage using traditional method may lead to erroneous readings without any intraoperative guide for the distance reached by the surgeon. To overcome the difficulty during pediatric therapeutic probing, usage of smart probes has been described.[1] In these kinds of probes on one side, there will be a mark placed at every 10 mm to know the distance reached from the punctum.

To improve the diagnostic as well as therapeutic utility in the cases of pathology related to the lacrimal drainage system, authors have made an effort by permanently engraving the numbers in millimeters scale on either side of the probe using cutting edge laser technology [Figure 1]a. The probe on one side has a measuring scale at every 2 mm (from 2 to 20 mm) [Figure 1]b and the other end has a measuring scale at every 5 mm (from 5 to 20 mm) [Figure 1]c.
Figure 1: (a) Calibrated Bowman's lacrimal probe. (b) On one end of the probe the number are engraved corresponding to a millimeters scale from 2 to 20 mm. (c) Similarly, on the other side of the probe the scale measures distance at every 5 mm (from 5 to 20 mm)

Click here to view


With the help of routine probes, the procedures are time-consuming and may give a false reading about the site of obstruction. But using this calibrated probe, the exact site of obstruction from the lacrimal punctum can be measured with the probe in situ and accurately as small as 1 mm distance. Similarly, in cases of canalicular obstruction, the level can be ascertained with the probe before the canalicular trephination. To conclude, using calibrated Bowman probe, the level of obstruction within the lacrimal system can be made out more accurately with minimal wastage of crucial time.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
  References Top

1.
Kothari M. Use of smart lacrimal probes. Indian J Ophthalmol 2011;59:70-1.  Back to cited text no. 1
[PUBMED]  [Full text]  


    Figures

  [Figure 1]



 

Top
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
References
Article Figures

 Article Access Statistics
    Viewed988    
    Printed25    
    Emailed0    
    PDF Downloaded151    
    Comments [Add]    

Recommend this journal