Glyxambi
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
  • Users Online: 665
  • Home
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2018  |  Volume : 66  |  Issue : 6  |  Page : 806-811

Accuracy of noncycloplegic refraction performed at school screening camps


1 Department of Paediatric Ophthalmology and Strabismus, Dr. Shroff's Charity Eye Hospital, New Delhi, India
2 Department of Ophthalmology, BHRC-Dr. Shroff Charity Eye Hospital, Mathura, Uttar Pradesh, India
3 Department of Ophthalmology, Binh Dinh Eye Hospital, Qui Nhon, Vietnam, Asia, India
4 Department of Community Ophthalmology, Dr. Shroff's Charity Eye Hospital, New Delhi, India

Correspondence Address:
Dr . Shailja Tibrewal
Dr. Shroff's Charity Eye Hospital, Daryaganj, New Delhi - 110 002
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijo.IJO_982_17

Rights and Permissions

Purpose: The aim of this study was to compare noncycloplegic refraction performed in school camp with that performed in eye clinic in children aged 6–16 years. Methods: A prospective study of children with unaided vision <0.2 LogMAR who underwent noncycloplegic retinoscopy (NCR) and subjective refraction (SR) in camp and subsequently in eye clinic between February and March 2017 was performed. A masked optometrist performed refractions in both settings. The agreement between refraction values obtained at both settings was compared using the Bland–Altman analysis. Results: A total of 217 eyes were included in this study. Between the school camp and eye clinic, the mean absolute error ± standard deviation in spherical equivalent (SE) of NCR was 0.33 ± 0.4D and that of SR was 0.26 ± 0.5D. The limits of agreement for NCR were +0.91D to − 1.09D and for SR was +1.15D to -1.06D. The mean absolute error in SE was ≤0.5D in 92.62% eyes (95% confidence interval 88%–95%). Conclusion: A certain degree of variability exists between noncycloplegic refraction done in school camps and eye clinic. It was found to be accurate within 0.5D of SE in 92.62% eyes for refractive errors up to 4.5D of myopia, 3D of cylinder, and 1.5D of hyperopia.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1085    
    Printed3    
    Emailed0    
    PDF Downloaded231    
    Comments [Add]    

Recommend this journal