Glyxambi
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
  • Users Online: 1802
  • Home
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2019  |  Volume : 67  |  Issue : 10  |  Page : 1663-1666

Clinical, ultrasonographic and optical coherence tomography correlation of optic nerve head cupping in glaucoma patients


Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India

Correspondence Address:
Dr. Amar Pujari
Room No 212, RPC 1 Hostel, Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, Ansari Nagar, New Delhi - 110 029
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijo.IJO_24_19

Rights and Permissions

Purpose: To ascertain if ultrasound (USG) B-scan examination of the optic nerve head (ONH) can be a useful tool to diagnose and quantify glaucomatous cupping. Methods: A cross-sectional observational study of 48 eyes of 48 patients with clear ocular media and cup-disc ratio of (CDR) ≥0.6 were included. The disc was studied by + 90D examination, USG B-scan and ONH Optical coherence tomography (OCT) by three masked observers. Observer-1 assessed the clinical CDR, observer-2recordedopticcup diameter on USG B-scan and observer-3performed ONH OCT to note the software computed average CDR. Measurements of cupping obtained by these 3 methods were compared and their relative strengths determined. The interdependency between variables was further studied using regression analysis. Results: Clinically assessed disc ratios of 0.6, 0.7, 0.8, 0.9, and total corresponded to USG cup measures of 1.02 ± 0.11 mm, 1.23 ± 0.14 mm, 1.35 ± 0.072 mm, 1.45 ± 0.084 mm, 1.75 ± 0.15 mm and OCT average CDR of 0.62 ± 0.087, 0.68 ± 0.060, 0.75 ± 0.078, 0.81 ± 0.036, 0.89 ± 0.038, respectively. There was an excellent correlation between the three arms, with Pearson's co-efficient (r) of 0.87, P < 0.001 between clinical and USG cupping; r = 0.89, P < 0.001 between clinical and OCT cupping; and r = 0.88, P < 0.001 between USG and OCT cupping. A relation of y = 1.64x + 0.03 was obtained between them, where y stands for USG cup diameter and x stands for the observed clinical CDR. Conclusion: Ultrasonographic measurement of optic cup diameter corresponds well to clinical ONH cupping. Therefore, it can reliably be used in quantifying ONH cupping in cases of media opacities which preclude optic disc visualization.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed186    
    Printed3    
    Emailed0    
    PDF Downloaded64    
    Comments [Add]    

Recommend this journal