• Users Online: 91893
  • Home
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2019  |  Volume : 67  |  Issue : 2  |  Page : 209-212

Iris and knot configuration after Single Pass Four Throw (SFT) pupilloplasty as imaged by the spectral-domain optical coherence tomography


Dr Agarwal's Eye Hospital and Eye Research Centre, Chennai, Tamil Nadu, India

Correspondence Address:
Dr. Amar Agarwal
Dr. Agarwal's Eye Hospital and Eye Research Centre, 19, Cathedral Road, Chennai - 600 086, Tamil Nadu
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijo.IJO_885_18

Rights and Permissions

Purpose: To analyze the morphological changes in the iris-knot complex configuration using spectral-domain optical coherence tomography (SD-OCT) following the single pass four throw (SFT) pupilloplasty. Methods: In this retrospective case series, eyes with SFT pupilloplasty were examined by SD-OCT (Optovue). Iris morphology compared to the normal iris, presence of specific patterns (single hump, double humps, peaks and valleys, tethering), prolene suture, knot complex (length and orientation), and intraocular lens (IOL) vault were evaluated. Results: Overall, 41 knots of 26 patients with a mean time duration of 3.1 ± 2 months from surgery were analyzed. Iris configurations seen were single hump (n = 28, 63.8%), double humps (n = 7, 17%), loop (n = 2, 4.8%), flat (n = 3, 7.3%), and mulberry (n = 1, 2.4%). The mean length and the height of the knot complex was 784.1 ± 433.7 μm and 317.7 ± 110.4 μm, respectively. Knot positions were at 3 clock hours in 9 eyes (21.9%), 9 in 8 eyes (19.5%), and others in 24 eyes (58.5%). Cut end of the prolene suture was detectable in 26 eyes (63.4%) as hyper-reflective line, and the mean cut length was 465.8 ± 321.1 μm. The suture was predominantly vertically oriented (80.6%) to the iris with a mean distance of 3.6 ± 0.3 mm (2.6–4 mm) away from corneal endothelium. The mean distance from the knot complex and the IOL was 289.2 ± 146 μm and the mean anterior chamber depth was 4.1 ± 0.1 mm. Conclusion: A significant change in iris configuration was noted after SFT pupilloplasty, and vertically oriented retained prolene suture was predominant with good endothelial vault.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2054    
    Printed50    
    Emailed0    
    PDF Downloaded258    
    Comments [Add]    
    Cited by others 3    

Recommend this journal