COMMENTARY
Year : 2019  |  Volume : 67  |  Issue : 2  |  Page : 256-257

Commentary: Choroidal thickness in the era of swept-source optical coherence tomography


Advanced Eye Center, Post Graduate Institute of Medical Education and Research (PGIMER), Chandigarh, India

Date of Web Publication23-Jan-2019

Correspondence Address:
Dr. Aniruddha Agarwal
Advanced Eye Center, Post Graduate Institute of Medical Education and Research (PGIMER), Sector 12, Chandigarh - 160 012
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijo.IJO_1893_18

Rights and Permissions

How to cite this article:
Agarwal A. Commentary: Choroidal thickness in the era of swept-source optical coherence tomography. Indian J Ophthalmol 2019;67:256-7

How to cite this URL:
Agarwal A. Commentary: Choroidal thickness in the era of swept-source optical coherence tomography. Indian J Ophthalmol [serial online] 2019 [cited 2024 Mar 29];67:256-7. Available from: https://journals.lww.com/ijo/pages/default.aspx/text.asp?2019/67/2/256/250670



In this issue of Indian Journal of Ophthalmology, the authors have performed a large study with 119 healthy patients (238 eyes) with an aim to establish a normative database of subfoveal choroidal thickness in Asian Indian eyes using the technology of swept-source (SS) optical coherence tomography (OCT).[1] The authors included subjects with a mean age of 28.7 years (range: 19–45 years). The authors concluded that the mean subfoveal choroidal thickness (in the central 1 mm) was 299.10 ± 131.2 μm compared with 294.8 ± 46.5 μm obtained using spectral-domain (SD) technology.[1] In the era of SS-OCT, which has inherent advantages of deeper choroidal penetration and lesser loss of sensitivity with depth, quantitative assessment of the choroid has gained relevance. SS-OCT provides distinct advantages of better delineation of retinal pigment epithelium–Bruch's complex and the sclerochoroidal junction, even in Asian eyes with heavy pigmentation.[2],[3] In this article, the authors have also focused on comparing their findings with SD-OCT, a technology that is widely used in most retinal practices world over.[1]

It is well known from published literature that choroidal thickness is a highly dynamic parameter that can alter with minor physiological processes such as posture and time of the day.[4],[5],[6],[7] Therefore, there are a number of caveats when assessing healthy individuals and patients for their choroidal thicknesses. Despite the challenges we face in quantifying the choroid, there are two aspects that need to be kept in mind when analyzing the images – topographical variations of the choroid [8] and volumetric analysis.[9] Normally, the choroidal thickness has a distinct pattern due to the anatomical configuration and blood flow. The choroid follows a contour as it thins out nasally toward the optic disc and is usually thickest around the fovea. In studies that focus on measurement of choroidal thickness, it is necessary to take this into account. With progressive research, variations in topography have assumed importance apart from calculation of the choroidal thickness, although much needs to be learnt yet. Similarly, with the premise that changes in hemodynamics and hemorheological parameters may be relevant too, assessment of choroidal volume has been performed by several authors to at least partly address this issue.[10],[11] Using three-dimensional imaging such as the modern SS-OCT, it may be possible to obtain total choroidal volume (at least in the scanned area). Choroidal volume is likely to supplement the information obtained from choroidal thickness measurements as it seems to reflect pathological alterations due to blood flow. In summary, choroidal volume analysis is another aspect which goes well beyond measurement of thickness values.

Optimal imaging analyses of SS-OCT (or even SD-OCT) scans requires assessment of both quantitative and qualitative changes. Diseases of the choroid can result in changes in the reflectivity, internal architecture, homogeneity, and back-scattering. Each of these parameters indicate pathological changes in the various layers of the choroid, such as activity of choroidal lesions (reduced back-scatter in the presence of active lesions and increased reflectance after healing and atrophy),[12] type of choroidal granuloma (based on homogeneity),[13] and choriocapillaris ischemia (loss of architecture of the inner choroid/choriocapillaris indicates ischemia).[14] Using newer metrics, it may be possible to provide quantitative measures of these qualitative changes. For instance, Dastiridou et al. devised a new metric of choroidal reflectivity in patients with birdshot chorioretinopathy.[15] Choroidal vascularity index (CVI) is another novel metric that enables assessment of changes in the choroidal vasculature and interstitium and has found applications in various conditions such as ocular tuberculosis,[12] panuveitis,[16] and other entities. In this technique of assessment, OCT scans can be processed using semi-automated analytical software to obtain CVI, which can be later compared with a normative database.

Measurement of choroidal thickness at the location of a lesion may have more relevance rather than measuring it at the subfoveal region, especially in pathologies that predominantly result in focal choroidal change, such as toxoplasmosis. Moreover, if the disease is focal, one must bear in mind the normal choroidal topographical variations mentioned previously. On the other hand, diseases of the pachychoroid spectrum (such as central serous chorioretinopathy), Vogt–Koyanagi–Harada's disease, birdshot chorioretinopathy, among others, result in diffuse thickening of the choroid. Thus, as a clinician, when applying the results of studies on choroidal thickness for our patients in our clinics, it is imperative to consider the nature of the disease being dealt with and its biological behavior. After obtaining choroidal thickness measurements, drawing conclusions is possible when the true nature of the pathology is defined, either focal or diffuse.

With newer advances in technology and higher image acquisition speed, it is truly possible to assess the choroid beyond the choroidal thickness in the present time. In the future, SS-OCT devices may be capable of generating choroidal thickness maps for all scanned patients which may serve as a reference to detect future changes. By combining various factors such as choroidal thickness, volume, reflectivity, CVI, and other aforementioned features, a composite choroidal evaluation may be available in the future, greatly impacting our understanding of disease pathology and improving patient outcomes.



 
  References Top

1.
Bhayana AA, Kumar V, Tayade A, Chandra M, Chandra P, Kumar A. Choroidal thickness in normal Indian eyes using swept-source optical coherence tomography. Indian J Ophthalmol 2019;67:252-5.  Back to cited text no. 1
  [Full text]  
2.
Motaghiannezam R, Schwartz DM, Fraser SE. In vivo human choroidal vascular pattern visualization using high-speed swept-source optical coherence tomography at 1060 nm. Invest Ophthalmol Vis Sci 2012;53:2337-48.  Back to cited text no. 2
    
3.
Diaz JD, Wang JC, Oellers P, Lains I, Sobrin L, Husain D, et al. Imaging the deep choroidal vasculature using spectral domain and swept source optical coherence tomography angiography. J Vitreoretin Dis 2018;2:146-54.  Back to cited text no. 3
    
4.
Tan K-A, Gupta P, Agarwal A, Chhablani J, Cheng CY, Keane PA, et al. State of science: Choroidal thickness and systemic health. Surv Ophthalmol 2016;61:566-81.  Back to cited text no. 4
    
5.
Xiong S, He X, Deng J, Lv M, Jin J, Sun S, et al. Choroidal thickness in 3001 Chinese children aged 6 to 19 years using swept-source OCT. Sci Rep 2017;7:45059.  Back to cited text no. 5
    
6.
Chew MC, Lim LW, Cheong KX, Sadda SR, Tan CSH. Assessing diurnal variation in choroidal thickness. Ophthalmic Surg Lasers Imaging Retina 2014;45:e29.  Back to cited text no. 6
    
7.
Rim TH, Lee CS, Kim K, Kim SS. Assessment of choroidal thickness before and after steep Trendelenburg position using swept-source optical coherence tomography. Br J Ophthalmol 2015;99:493-99.  Back to cited text no. 7
    
8.
Tan CSH, Cheong KX, Lim LW, Li KZ. Topographic variation of choroidal and retinal thicknesses at the macula in healthy adults. Br J Ophthalmol 2014;98:339-44.  Back to cited text no. 8
    
9.
Simonett JM, Chan EW, Chou J, Skondra D, Colon D, Chee CK, et al. Quantitative analysis of en face spectral-domain optical coherence tomography imaging in polypoidal choroidal vasculopathy. Ophthalmic Surg Lasers Imaging Retina 2017;48:126-33.  Back to cited text no. 9
    
10.
Spaide RF. Volume-rendered optical coherence tomography of diabetic retinopathy pilot study. Am J Ophthalmol 2015;160:1200-10.  Back to cited text no. 10
    
11.
Gupta P, Jing T, Marziliano P, Cheung CY, Baskaran M, Lamoureux EL, et al. Distribution and determinants of choroidal thickness and volume using automated segmentation software in a population-based study. Am J Ophthalmol 2015;159:293-301.e3.  Back to cited text no. 11
    
12.
Agarwal A, Agrawal R, Khandelwal N, Invernizzi A, Aggarwal K, Sharma A, et al. Choroidal structural changes in tubercular multifocal serpiginoid choroiditis. Ocul Immunol Inflamm 2018;26:838-44.  Back to cited text no. 12
    
13.
Invernizzi A, Agarwal A, Mapelli C, Nguyen QD, Staurenghi G, Viola F. Longitudinal follow-up of choroidal granulomas using enhanced depth imaging optical coherence tomography. Retina (Philadelphia, Pa) 2017;37:144-53.  Back to cited text no. 13
    
14.
Invernizzi A, Agarwal A, Cozzi M, Viola F, Nguyen QD, Staurenghi G. Enhanced depth imaging optical coherence tomography features in areas of choriocapillaris hypoperfusion. Retina (Philadelphia, Pa) 2016;36:2013-21.  Back to cited text no. 14
    
15.
Dastiridou AI, Bousquet E, Kuehlewein L, Tepelus T, Monnet D, Salah S, et al. Choroidal imaging with swept-source optical coherence tomography in patients with birdshot chorioretinopathy: Choroidal reflectivity and thickness. Ophthalmology 2017;124:1186-95.  Back to cited text no. 15
    
16.
Agrawal R, Salman M, Tan KA, Karampelas M, Sim DA, Keane PA, et al. Choroidal Vascularity Index (CVI) – A novel optical coherence tomography parameter for monitoring patients with panuveitis? PLoS One 2016;11:e0146344.  Back to cited text no. 16
    




 

Top
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
References

 Article Access Statistics
    Viewed1651    
    Printed36    
    Emailed0    
    PDF Downloaded181    
    Comments [Add]    

Recommend this journal