We describe a case of 34-year-old male with post penetrating keratoplasty glaucoma, post trabeculectomy with aphakia in the only seeing eye, in which a modified surgical technique of inserting Ahmed glaucoma valve (AGV) tube in vitreous cavity was done to reduce the risks associated with pars plana incision during pars plana vitrectomy (PPV). A hybrid 20-25 gauge PPV was done concurrently, implant fixed to sclera, and tube inserted through the 25 gauge sclerotomy port in supero-temporal quadrant. Visual acuity and intraocular pressure remained stable during 1-year follow-up.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1508    
    Printed34    
    Emailed0    
    PDF Downloaded181    
    Comments [Add]    
    Cited by others 2    

Recommend this journal