A comparison of the corneal biomechanics in pseudoexfoliation syndrome, pseudoexfoliation glaucoma, and healthy controls using Corvis® Scheimpflug Technology


1 Department of Glaucoma, Narayana Nethralaya Foundation, Bengaluru, Karnataka, India
2 University Eye Clinic Maastricht, University Medical Center, Maastricht, The Netherlands

Correspondence Address:
Dr. Zia S Pradhan
Department of Glaucoma, Narayana Nethralaya, Bengaluru, Karnataka
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijo.IJO_1550_19

Rights and Permissions

Purpose: To compare the corneal biomechanical parameters among pseudoexfoliation syndrome (PXF), pseudoexfoliation glaucoma (PXG), and healthy controls using Corvis Scheimpflug Technology (ST). Methods: A prospective, cross-sectional study of 141 treatment-naïve eyes that underwent Corvis ST was conducted. These included 42 eyes with PXF, 17 eyes of PXF with ocular hypertension (PXF + OHT) defined as intraocular pressure (IOP) >21 mmHg without disc/field changes, 37 eyes with PXG, and 45 healthy controls. Corneal biomechanical parameters, which included corneal velocities, length of corneal applanated surface, deformation amplitude (DA), peak distance, and radius of curvature, were compared among the groups using analysis of variance models. Results: The four groups were demographically similar. The mean IOP was lower in the controls (15.6 ± 3 mmHg) and PXF group (16.0 ± 3 mmHg) compared to the other two groups (>24 mmHg). Corneal pachymetry was similar across the four groups. Mean DA was significantly lower (P < 0.0001) in the PXG group (0.91 ± 0.18 mm) and the PXF + OHT group (0.94 ± 0.13 mm) when compared to the PXF (1.10 ± 0.11 mm) and control groups (1.12 ± 0.14 mm). Corneal velocities were also found to be statistically significantly lower in PXG and PXF + OHT compared to the PXF and control groups. However, after adjusting for age and IOP, there was no difference in any of the biomechanical parameters among the four groups. Conclusion: Corneal biomechanical parameters measured on Corvis ST are not different between healthy controls and eyes with PXF and PXG. Since PXG is a high-pressure glaucoma, corneal biomechanics may not play an important role in its diagnosis and pathogenesis.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed244    
    Printed0    
    Emailed0    
    PDF Downloaded71    
    Comments [Add]    

Recommend this journal