%A Can, Ertugrul %A Basaran, Resat %A Gul, Adem %A Birinci, Hakki %T Scleral fixation of one piece intraocular lens by injector implantation %9 Original Article %D 2014 %J Indian Journal of Ophthalmology %R 10.4103/0301-4738.141042 %P 857-860 %V 62 %N 8 %U https://journals.lww.com/ijo/pages/default.aspx/article.asp?issn=0301-4738;year=2014;volume=62;issue=8;spage=857;epage=860;aulast=Can %8 August 1, 2014 %X Aim of Study: With an ab-interno technique of transscleral suturing of current one-piece posterior chamber intraocular lenses (PC IOLs) by injector implantation in the absence of capsular support, we aimed to demonstrate the possibility of the implantation of one-piece acrylic PC IOLs that might be produced in the future for only scleral fixation through small clear corneal incision. Materials and Methods: Case report and literature review. Results: This procedure has been performed in eight aphakic eyes with four different types of IOLs. Good centration was achieved with minimal technical effort. All patients had well-centered and stable lenses postoperatively during 9-18 months follow-up. Conclusion: We managed to decrease the risks of surgical trauma and intricate surgical maneuvers requirement. With this technique, excessive fluid leakage and consecutive hypotony can be minimized. %0 Journal Article %I Wolters Kluwer Medknow Publications %@ 0301-4738