Indian Journal of Ophthalmology

ORIGINAL ARTICLE
Year
: 2010  |  Volume : 58  |  Issue : 4  |  Page : 307--312

Ocular aberrations after wavefront optimized LASIK for myopia


Prema Padmanabhan, Subam S Basuthkar, Roy Joseph 
 Medical Research Foundation, Sankara Nethralaya, 18 College Road, Chennai, Tamil Nadu, India

Correspondence Address:
Prema Padmanabhan
Medical Research Foundation, Sankara Nethralaya, 18 College Road, Chennai
India

Abstract

Purpose: To study the change in ocular aberrations after wavefront optimized (WFO) laser in situ keratomileusis ( Lasik ) for correction of myopia and to analyze causative factors that may influence them. Materials and Methods: This was a prospective case series. WFO Lasik was performed for the correction of myopia, using the hansatome (Bausch and Lomb) microkeratome to create the flap and the Allegretto laser (Wavelight Technologie) to perform the ablation. The Allegretto wave analyser (Tscherning-type) measured the ocular aberrations prior to Lasik , one month and six months postoperatively. Results: The mean age of the 59 patients included in the study was 25±5.64 years and the mean spherical equivalent of the 117 eyes that underwent Lasik0 was -5.33±1.22 preoperatively and -0.21±0.38 postoperatively. Hundred and two eyes of 117 (87%) achieved uncorrected visual acuity (UCVA) of 20/20 or better after WFO Lasik and 104 of 117 eyes (89%) were within ±0.5D of the attempted refractive correction. There was a 1.96-fold increase in total root-mean-square of higher order aberrations. Induced changes in seven of the 22 higher order Zernike terms showed a significant linear correlation with the refractive correction attempted. Larger ablation zones induced less spherical aberration. Conclusion: In spite of an excellent visual outcome, WFO Lasik induces significant higher order aberrations. Large ablation zones reduce the induction of spherical aberration.



How to cite this article:
Padmanabhan P, Basuthkar SS, Joseph R. Ocular aberrations after wavefront optimized LASIK for myopia.Indian J Ophthalmol 2010;58:307-312


How to cite this URL:
Padmanabhan P, Basuthkar SS, Joseph R. Ocular aberrations after wavefront optimized LASIK for myopia. Indian J Ophthalmol [serial online] 2010 [cited 2024 Mar 28 ];58:307-312
Available from: https://journals.lww.com/ijo/pages/default.aspx/text.asp?2010/58/4/307/64139


Full Text

Excimer laser surgery is an effective method for the correction of spherocylindrical refractive errors of the eye. Although advances in technology were initially focused on improving the precision of refractive outcomes, recent efforts attempt to improve the optical quality of vision after such surgery.

The incidence of visual complaints by patients even after a successful refractive surgery, ranges from 3 to 40%. [1] These problems have been attributed to an increase in higher order aberrations (HOA) [2] following the procedure, due to multiple causes like flap-induced irregularities, decentration, variation in hydration of cornea during ablation and biomechanical changes resulting from laser surgery.

Studies have indicated that HOA of the cornea increase after radial keratotomy, [3] photo refractive keratectomy (PRK) [4] and laser in situ keratomileusis (LASIK). [5],[6],[7] Although the surgical changes produced by refractive surgery occur on the anterior corneal surface, several groups have reported changes in the posterior corneal curvature after laser refractive surgery. [8],[9],[10] It follows that the analysis of the total wavefront aberrations of the eye would provide the most direct and complete measurement of retinal image quality and therefore can be directly related to visual performance. [6]

Various studies have shown a significant increase in total ocular wavefront aberrations following refractive surgery. [11],[12],[13],[14] A comparison across studies is difficult because of the variability in the method of wavefront sensing adopted, the spot size and beam profile of the laser used, the ablation and transition zone diameters and the type and range of refractive errors treated. Most of these studies, however, reported the results of conventional corneal ablation, meant to treat only spherocylindrical errors, with ablation algorithms based on the paraxial formula of Munnerlyn et al. [15] These studies did show a significant increase in total HOA, particularly in the spherical-like and coma-like aberrations. [11],[12],[13],[14]

The Wavelight Allegretto excimer laser (Wavelight Technolgie, Inc., Erlangen) has a proprietary ablation algorithm that has a population-averaged spherical aberration correction built into it, and is referred to as "wavefront optimized (WFO) treatment". The WFO ablation profile was calculated based on subjective refraction and the amount of spherical aberration expected to be induced by conventional corneal laser surgery. The precompensation of this induced spherical aberration results in a larger amount of tissue removal in the periphery (approximately 35% more) than in the classic ablation profile, leaving the central ablation depth unchanged. [16] It does not take the unique aberration of each individual into account, and therefore cannot be termed a customized algorithm. However, it is meant to reduce the induced spherical aberration and thus improve the quality of the retinal image as compared to a conventional spherocylindrical correction.

This study aimed at characterizing the aberration profile of myopic eyes before and one month and six months after a WFO LASIK and studied the various surgical factors that could have influenced the changes induced by the procedure.

 Materials and Methods



This was a prospective study of patients who underwent LASIK for the correction of myopia or myopic astigmatism between January 2005 and June 2005. Eyes with any ocular pathology or previous surgery were excluded. Patients with any contraindication for LASIK (unstable refraction, keratoconus suspects, dry eyes, patients with collagen vascular disorders) were also excluded from the study. Patients willing to come back for follow-up visits one month and six months after surgery were enrolled in the study. All suitable patients signed an informed consent before being enrolled into the study which was approved by the institution review board and adhered to the tenets of the Declaration of Helsinki.

The ocular wavefront aberrations were measured by the Allegretto wave analyzer (WaveLight Technologie Inc., Erlangen AG) preoperatively, one month and six months postoperatively after pupils were pharmacologically dilated. Well-centered images with a grid pattern conforming to the criteria described in the Allegro Analyzer procedure manual were chosen for analysis. The Zernike coefficients up to the 6th radial-order were analyzed for a pupil diameter of 6 mm, and converted to the notation prescribed by the VSIA taskforce. [17] The appropriate algebraic conversion of all coefficients with an odd symmetry along the Y-axis in all left eyes allowed the data of both eyes to be analyzed together. The Hansatome (Bausch and Lomb) automated microkeratome was used to create a 9.5-mm corneal flap with a superior hinge (attempted thickness 160 μm).

The Wavelight Allegretto excimer laser (spot size 0.95) was used to perform the photoablation.

We defined "induced change" in aberration as the algebraic difference between the postoperative and preoperative Zernike coefficients, taking their direction (positive or negative) into account. We defined "factor of change" as the ratio of the "induced change" to the preoperative Zernike coefficient. The SPSS (Version 13) was used for statistical analysis.

 Results



LASIK was performed in 117 eyes of 59 patients (59 right eyes and 58 left eyes), with a mean age of 25 ± 5.64 years (range 18 to 35 years). Nineteen eyes had myopia and 98 had myopic astigmatism, with a mean refractive astigmatism of -0.85 ± 0.73 D (range -0.25 to -4.0D). The pre-operative mean spherical equivalent (SE) was -5.33 ± 1.22 (range -1 to -10D), and the best corrected visual acuity (BCVA) on the logMAR scale was 0.028 ± 0.139. The optic zone was 6 mm in 72 eyes, 6.5 mm in 41 eyes and 5.5 mm in four eyes. A residual stromal bed of at least 250 μ was retained at the end of ablation in all eyes. While all 59 patients came for a one month follow-up visit, 32 patients reported for a six months' evaluation as well.

At one month after LASIK, 102 of 117 eyes (87%) had an uncorrected visual acuity (UCVA) of 20/20 or better and 104 of 117 eyes (89%) were within +0.50D of the attempted refractive correction. The mean postoperative SE was -0.21±0.38 and the BCVA (logMAR) was -0.50+0.04.

All the 27 aberrations showed a change from their preoperative values, and this was statistically significant (P rd and 4 th radial orders. The largest magnitude of induced change was observed with vertical coma (-0.21±0.32) and with spherical aberration (0.17±0.19).

[Figure 2] compares the root mean square (RMS) of HOA in each radial order from 3 rd through 6 th and the total HOA before and after LASIK. The RMS of total HOA following LASIK was 1.96 times that before LASIK. [Table 2] shows the RMS of 3 rd and 4 th order aberrations and total spherical aberration (Z04 and Z06) and the ratio of postoperative/preoperative RMS.

The eyes were grouped according to the spherical equivalent of attempted correction into eight groups (8D in 1D intervals). A linear regression analysis was done between the induced change in aberration of each individual Zernike term and each group of refractive error.

Seven of the 22 higher order Zernike terms showed a statistically significant linear relationship between the induced change in aberration and the attempted correction of refractive error [Table 3] and [Figure 3]. The induced change in RMS of total HOA also showed a trend towards an increase with increasing grades of myopia corrected [Table 4].

Seventy-two eyes had an optical zone of 6 mm and 41 eyes had an optical zone of 6.5 mm. Induced spherical aberration was statistically significantly less (independent t-test, P = [1],[2],[3],[4],[5],[6],[7] These, in turn, have been shown to correlate with a loss in low-contrast visual acuity and contrast sensitivity and with night vision problems like haloes, starbursts and glare. [2],[7],[18],[19] An understanding and quantification of the aberrations induced by laser refractive surgery is an important prerequisite to formulate algorithms for customized laser procedures. While some studies have based their analysis on corneal topography data, [3],[4],[7] a few others have recognized that total ocular wavefront measurements are better predictors of retinal image quality. [11],[12]

All the Zernike terms across the six radial orders measured showed changes in magnitude following LASIK, some more than others. Seiler et al. [11] reported a significant increase in four out of 22 higher order Zernike terms in 15 eyes after PRK. This study showed 10 out of 22 Zernike terms that had significant increase in the magnitude of aberrations after LASIK. The difference in procedure, limit of treated myopia and in the laser used, could explain this difference. Although some studies demonstrate that the creation of the LASIK flap induces significant HOA, [20] others report that most HOA after LASIK are induced by the ablation and not the flap. [21],[30] Waheed et al.,[29] showed no statistically significant relationship between the position of the hinge of the flap and the induced coma and found that flap aberrations showed no predictable trends and accounted for less than a quarter of the increase in post-laser aberrations. Recent studies suggest that flaps created with the Intralase femtosecond laser were associated with less changes in HOA compared to the Hansatome flap. [22],[23]

The ratio of postoperative to preoperative HOA [Table 2] was more comparable to the published results of Barriuso et al. [12] than those of Seiler et al. [11] Our results with the 4th order aberrations and with spherical aberration in particular, appear to be better than those reported by the others. Waheed et al.,[29] reported an increase in spherical aberration of 0.31 ± 0.08 at one to three months following conventional LASIK, whereas our study showed a 0.17 ± 0.19μ increase in spherical aberration one month following WFO LASIK. The ratio of postoperative to preoperative RMS of total spherical aberration (i.e. 4 th and 6th order spherical aberration) was 1.86 in our study (with pupil diameter 6 mm) compared to 3.99 in the study by Barriuso et al. [12] (with pupil dia 6.5 mm). Herein lies the unique feature of the WFO ablation profile, a proprietary algorithm of the wavelight Allegretto excimer laser, that pre-programs a population-based spherical aberration correction factor. Here, the ablation depth of the WFO ablation profile is up to 35% larger in the periphery than in the classic ablation profile. [16]

Our study, like some others, [6],[12] showed a statistically significant linear relationship (P = et al. [24] proposed that the biomechanical response of the cornea to laser photoablation for myopia could further induce spherical aberration. Marcos et al., [6] showed, by using a combination of aberrometry and anterior corneal topography that a possible change in posterior corneal shape following LASIK would increase the negative internal spherical aberrations, and thereby attenuate the impact of the positive spherical aberration induced by the changes in the anterior corneal curvature.

Based on theoretical models, a few suggested ablation profiles could be considered to reduce the spherical aberration following LASIK. [25],[26] These may be important in the context of wavefront-guided treatment. However, it is important to remember that biological, optical and mechanical effects will still induce unpredictable changes even if a perfect ablation is performed.

Our study showed a fivefold increase in the amount of vertical coma, and represented the highest magnitude of induced change among all the HOA. Unlike Barriuso et al., [12] our study showed a linear correlation between induced coma and the attempted refractive correction although the correlation coefficient (r value) was only 0.19. There was no significant influence of the diameter or shape of the ablation zone on the magnitude of the induced coma. While Seiler et al., [11] found that 4 th order aberrations dominated in postoperative eyes, our study showed that 3 rd order aberrations continue to dominate after Lasik0 . There could be at least three sources of induced coma. First, even subclinical decentrations (less than 1mm) have been found to be a major factor in inducing coma. [1] Although the use of an eye tracker has helped to avoid severe decentrations, it does not ensure perfect centration. [27] Second, as suggested by Pallikaris et al. [20] the creation of a corneal flap with a microkeratome itself may induce coma along the direction of the hinge (superior hinge in this study), although the study by Waheed et al. [29] showed no predictable trends in flap-induced aberrations and no significant association between hinge position and coma. Porter et al. [21] demonstrated that while there was a significant sharp increase in vertical coma 20 min after the flap cut, this effect subsided in 24 h, suggesting that the postoperative coma reported universally in all studies, is due to the actual laser ablation and not the microkeratome incision, which was also the conclusion of the study by Waheed et al. [29] A third possible cause for postoperative coma could be an asymmetry in wound healing as suggested by immunohistological studies. [28]

Chalita et al., [2] interestingly, found no correlation between vertical coma and optical symptoms, although horizontal coma was associated with double vision. This shows the importance of studying the orientation (positive or negative) of individual aberrations, rather than the RMS values alone.

LASIK induced a change in all the Zernike terms across six radial orders, affecting some Zernike terms more than others. The total HOA increased by a factor of 1.96. Vertical coma and spherical aberration showed the largest magnitude of change. The induced change in spherical aberration bore a linear relationship with the attempted refractive correction. Larger treatment zones were associated with smaller magnitudes of induced spherical aberration, but had no influence on the magnitude of induced coma.

Further studies on similar large datasets are required to confirm the occurrence and magnitude of such changes. The influence of biomechanical and wound healing on these changes also need to be further elucidated. This would help improve current treatment algorithms and result in better outcomes after Lasik0 .

References

1Mrochen M, Kaemmerer M, Mierdel P, Seiler T. Increased higher-order optical aberrations after laser refractive surgery: A problem of subclinical decentration. J Cataract Refract Surg 2001;27:362-9.
2Chalita MR, Chavala S, Xu M, Krueger RR. Wavefront analysis in post-LASIK eyes and its correlation with visual symptoms, refraction, and topography. Ophthalmology 2004;111:447-53.
3Applegate RA, Howland HC, Sharp RP, Cottingham AJ, Yee RW. Corneal aberrations and visual performance after radial keratotomy. J Refract Surg 1998;14:397-407.
4Oliver KM, Hemenger RP, Corbett MC, O'Brart DP, Verma S, Marshall J, et al. Corneal optical aberrations induced by photorefractive keratectomy. J Refract Surg 1997;13:246-54.
5Oshika T, Klyce SD, Applegate RA, Howland HC, El Danasoury MA. Comparison of corneal wavefront aberrations after photorefractive keratectomy and laser in situ keratomileusis. Am J Ophthalmol 1999;127:1-7.
6Marcos S, Barbero S, Llorente L, Merayo-Lloves J. Optical response to LASIK surgery for myopia from total and corneal aberration measurements. Invest Ophthalmol Vis Sci 2001;42:3349-56.
7Oshika T, Miyata K, Tokunaga T, Samejima T, Amano S, Tanaka S, et al. Higher order wavefront aberrations of cornea and magnitude of refractive correction in laser in situ keratomileusis. Ophthalmology 2002;109:1154-8.
8Kamiya K, Oshika T, Amano S, Takahashi T, Tokunaga T, Miyata K. Influence of excimer laser photorefractive keratectomy on the posterior corneal surface. J Cataract Refract Surg 2000;26:867-71.
9Naroo SA, Charman WN. Changes in posterior corneal curvature after photorefractive keratectomy. J Cataract Refract Surg 2000;26:872-8.
10Seitz B, Torres F, Langenbucher A, Behrens A, Suαrez E. Posterior corneal curvature changes after myopic laser in situ keratomileusis. Ophthalmology 2001;108:666-72.
11Seiler T, Kaemmerer M, Mierdel P, Krinke HE. Ocular optical aberrations after photorefractive keratectomy for myopia and myopic astigmatism. Arch Ophthalmol 2000;118:17-21.
12Moreno-Barriuso E, Lloves JM, Marcos S, Navarro R, Llorente L, Barbero S. Ocular aberrations before and after myopic corneal refractive surgery: LASIK-induced changes measured with laser ray tracing. Invest Ophthalmol Vis Sci 2001;42:1396-403.
13Marcos S. Aberrations and visual performance following standard laser vision correction. J Refract Surg 2001;17:596-601.
14Yamane N, Miyata K, Samejima T, Hiraoka T, Kiuchi T, Okamoto F, et al. Ocular higher-order aberrations and contrast sensitivity after conventional laser in situ keratomileusis. Invest Ophthalmol Vis Sci 2004;45:3986-90.
15Munnerlyn CR, Koons SJ, Marshall J. Photorefractive keratectomy: A technique for laser refractive surgery. J Cataract Refract Surg 1988;14:46-52.
16Mrochen M, Donitzky C, Wόllner C, Lφffler J. Wavefront-optimized ablation profiles: theoretical background. J Cataract Refract Surg 2004;30:775-85.
17Thibos LN, Applegate AR, Schwiegerling JT, Webb R, VSIA Standards Taskforce Members. Standards for reporting the optical aberrations of eyes. OSA trends in optics and photonics. In: Lakshminarayanan V, editor. Vision science and its applications. Washington D.C.: Optical Society of America; 2000. P. 232-44.
18Pιrez-Santonja JJ, Sakla HF, Aliσ JL. Contrast sensitivity after laser in situ keratomileusis. J Cataract Refract Surg 1998;24:183-9.
19Chan JW, Edwards MH, Woo GC, Woo VC. Contrast sensitivity after laser in situ keratomileusis. one-year follow-up. J Cataract Refract Surg 2002;28:1774-9.
20Pallikaris IG, Kymionis GP, Panagopoulou SI, Siaganos CS, Theodorakis MA, Pallikaris AI. Induced optical aberrations following formation of a Lasik0 flap. J Cataract Refract Surg 2002;28:1737-41.
21Porter J, MacRae S, Yoon G, Roberts C, Cox IG, Williams DR. Separate effects of the microkeratome incision and laser ablation on the eye's wave aberration. Am J Ophthalmol 2003;136:327-37.
22Tran DB, Sarayba MA, Bor Z, Garufis C, Duh YJ, Soltes CR,
23et al. Randomized prospective clinical study comparing induced aberrations with IntraLase and Hansatome flap creation in fellow eyes: potential impact on wavefront-guided laser in situ keratomileusis. J Cataract Refract Surg 2005;31:97-105.
24Durrie DS, Kezirian GM. Femtosecond laser versus mechanical keratome flaps in wavefront-guided laser in situ keratomileusis: Prospective contralateral eye study. J Cataract Refract Surg 2005;31:120-6.
25Dupps WJ Jr, Roberts C. Effect of acute biomechanical changes on corneal curvature after photokeratectomy. J Refract Surg 2001:17:658-69.
26Schwiegerling J, Snyder RW. Corneal ablation patterns to correct for spherical aberration in photorefractive keratectomy. J Cataract Refract Surg 2000;26:214-21.
27Manns F, Ho A, Parel JM, Culbertson W. Ablation profiles for wavefront-guided correction of myopia and primary spherical aberration. J Cataract Refract Surg 2002;28:766-74.
28Tsai YY, Lin JM. Ablation centration after active eye-tracker-assisted photorefractive keratectomy and laser in situ keratomileusis. J Cataract Refract Surg 2000;26:28-34.
29Wachtlin J, Langenbeck K, Schrόnder S, Zhang EP, Hoffmann F. Immunohistology of corneal wound healing after photorefractive keratectomy and laser in situ keratomileusis. J Refract Surg 1999;15:451-8.
30Waheed S, Chalita MR, Xu M, Krueger RR. Flap-induced and laser-induced ocular aberrations in a two-step LASIK procedure. J Refract Surg 2005;21:346-52.