Indian Journal of Ophthalmology

ORIGINAL ARTICLE
Year
: 2015  |  Volume : 63  |  Issue : 11  |  Page : 837--842

Diagnostic accuracy of posterior pole asymmetry analysis parameters of spectralis optical coherence tomography in detecting early unilateral glaucoma


Paaraj Dave1, Juhi Shah2 
1 Department of Glaucoma, Dr. T V Patel Eye Institute; Dave Eye Clinic, Vadodara, Gujarat, India
2 Department of Glaucoma, Dr. T V Patel Eye Institute, Vadodara, Gujarat, India

Correspondence Address:
Paaraj Dave
Dr. T V Patel Eye Institute, Vinoba Bhave Road, Salatwada, Vadodara - 390 001, Gujarat
India

Purpose: To report the diagnostic ability of posterior pole asymmetry analysis (PPAA) parameters of spectralis optical coherence tomography (OCT) in detecting early unilateral glaucoma. Methods: A prospective, cross-sectional study which included 80 eyes of 80 normal subjects and 76 eyes of 76 patients with unilateral early primary open-angle glaucoma by Hodapp-Anderson-Parrish classification. All subjects were of age more than 18 years, best-corrected visual acuity 20/40 or better, and a refractive error within ± 5 diopter (D) sphere and ± 3 D cylinder. Control subjects had a normal ocular examination, intraocular pressure (IOP) <22 mmHg, no past history of high IOP, no family history of glaucoma, normal optic disc morphology, and visual field in both eyes. One eye of the control subject was randomly included. All eyes underwent OCT for retinal nerve fiber layer (RNFL) analysis and PPAA. The number of continuous black squares was noted in the asymmetry analysis (right-left + hemisphere asymmetry). The area under curve (AUC) was calculated for all OCT parameters. Results: The best value for AUC for RNFL analysis was 0.858 for the inferotemporal quadrant thickness. This was similar to the best value for AUC for PPAA which was 0.833 for the inferior macular thickness parameter (P = 0.5). The AUC for the right-left and the hemisphere asymmetry part of PPAA was 0.427 and 0.499, respectively. Conclusion: The macular thickness PPAA parameters were equally good as the RNFL parameters. However, the asymmetry analysis parameters performed poorly and need further refinement before its use in early unilateral glaucoma diagnosis.


How to cite this article:
Dave P, Shah J. Diagnostic accuracy of posterior pole asymmetry analysis parameters of spectralis optical coherence tomography in detecting early unilateral glaucoma.Indian J Ophthalmol 2015;63:837-842


How to cite this URL:
Dave P, Shah J. Diagnostic accuracy of posterior pole asymmetry analysis parameters of spectralis optical coherence tomography in detecting early unilateral glaucoma. Indian J Ophthalmol [serial online] 2015 [cited 2020 Jul 12 ];63:837-842
Available from: http://www.ijo.in/article.asp?issn=0301-4738;year=2015;volume=63;issue=11;spage=837;epage=842;aulast=Dave;type=0