Indian Journal of Ophthalmology

ORIGINAL ARTICLE
Year
: 2019  |  Volume : 67  |  Issue : 9  |  Page : 1410--1416

Gas permeable contact lens fitting in keratoconus: Comparison of different guidelines to back optic zone radius calculations


Sara Ortiz-Toquero1, Guadalupe Rodriguez1, Victoria de Juan2, Raul Martin3 
1 Universidad de Valladolid, Departamento de Física Teórica, Atómica y Óptica, Valladolid, España; Universidad de Valladolid, Instituto Universitario de Oftalmobiología Aplicada (IOBA), Valladolid, España; Optometry Research Group, IOBA Eye Institute, School of Optometry, University of Valladolid, Valladolid, Spain
2 Optometry Research Group, IOBA Eye Institute, School of Optometry, University of Valladolid, Valladolid; Department of Ophthalmology, Ramón y Cajal University Hospital, Madrid, Spain
3 Universidad de Valladolid, Departamento de Física Teórica, Atómica y Óptica, Valladolid, España; Universidad de Valladolid, Instituto Universitario de Oftalmobiología Aplicada (IOBA), Valladolid, España; Optometry Research Group, IOBA Eye Institute, School of Optometry, University of Valladolid, Valladolid, Spain; Faculty of Health and Human Sciences, Plymouth University, Plymouth, United Kingdom

Correspondence Address:
Dr. Raul Martin
School of Health Professions, Faculty of Health and Human Sciences, Plymouth University, Peninsula Allied Health Centre, Derriford Road, Plymouth, PL6 8BH, UK and Optometry Research Group, IOBA Eye Institute, School of Optometry (University of Valladolid), Valladolid

Purpose: Compare the agreement between the finally fitted back optic zone radius (BOZR) of a spherical gas permeable (GP) contact lense (CL) with those proposed by different guidelines currently available to fit GP CLs in keratoconus. Methods: The BOZR fitted in 81 keratoconus eyes (46 patients) were recorded and compared with the BOZR calculated with ten different guidelines (identified after a literature review) proposed to calculate the first diagnostic lens BOZR to be fitted in keratoconus. Arithmetic and absolute mean difference between both BOZR were calculated (paired t-test). The success rate of each guideline (difference between both BOZR ≤0.05 mm) was calculated for different keratoconus stages (Amsler–Krumeich classification). Agreement between BOZR was evaluated using Bland-Altman analysis. Results: The BOZR proposed by all guidelines correlated with the final BOZR that was fitted (R2 > 0.71; P < 0.01). A statistically significant difference was found between the BOZR suggested by all guidelines and the BOZR that was prescribed (P < 0.05), except for three Guidelines (P ≥ 0.11). CALCULENS.com presented the best agreement (mean difference of 0.00 ± 0.12 mm), and 50.6% of cases showed ≤0.05 mm of difference with the BOZR that was fitted. However, the worst guideline showed an agreement of −0.38 ± 0.22 mm, and just 3.8% of cases had ≤0.05 mm of difference with the final fitted BOZR. Conclusion: BOZR calculated with most of the analyzed guidelines shows statistical differences with final fitted BOZR, suggesting a lack of clinical validation of these guidelines. The selection of the BOZR with CALCULENS.com could provide a better starting point for spherical GP CL fitting in keratoconus eyes.


How to cite this article:
Ortiz-Toquero S, Rodriguez G, de Juan V, Martin R. Gas permeable contact lens fitting in keratoconus: Comparison of different guidelines to back optic zone radius calculations.Indian J Ophthalmol 2019;67:1410-1416


How to cite this URL:
Ortiz-Toquero S, Rodriguez G, de Juan V, Martin R. Gas permeable contact lens fitting in keratoconus: Comparison of different guidelines to back optic zone radius calculations. Indian J Ophthalmol [serial online] 2019 [cited 2020 Apr 2 ];67:1410-1416
Available from: http://www.ijo.in/article.asp?issn=0301-4738;year=2019;volume=67;issue=9;spage=1410;epage=1416;aulast=Ortiz-Toquero;type=0