ORIGINAL ARTICLE |
|
Year : 1988 | Volume
: 36
| Issue : 1 | Page : 10-11 |
|
Carbachol as miotic agent in intra-ocular lens implant surgery
Jitendra Agarwal
Cook's Compound Ghasiari Mandi, Lucknow-226001, India
Correspondence Address:
Jitendra Agarwal Cook's Compound Ghasiari Mandi, Lucknow-226001 India
 Source of Support: None, Conflict of Interest: None  | Check |
PMID: 3253191 
|
|
The intra cameral use of 0.025% carbachol as a miotic agent in anterior chamber intraocular lens implant surgery us reported in 15 cases. Carbachol produced prompt and effective moisis and was found to be harmless and non-irritating to the anterior chamber structures. A rebound dialatation of the pipit was noticed in the post operative period in 3 of our first 5 cases where only carbachol was used. For prolonged miosis instillation of a more powerful miotic like pilocarpine is recommended at the completion of surgery:
|
|
|
|
[FULL TEXT] [PDF Not available]* |
|
 |
|