A comparative study of the use of Pyrex glass tubes and the polyethylene tubes in conjunctivo-dacryocystorhinostomy is presented in 20 patients. The various factors contributing to the success of the surgery are discussed. The merits and demerits of the two types of tubes used are also highlighted. |
|
|
|