Delayed accumulation of lens material behind the foldable intraocular lens


Sri Sankaradeva Nethralaya, Beltola, Guwahati, Assam, India

Date of Submission24-Dec-2006
Date of Acceptance04-Mar-2007

Correspondence Address:
Harsha Bhattacharjee
Sri Sankaradeva Nethralaya, Beltola, Guwahati - 781 028, Assam
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0301-4738.36490

Rights and Permissions
  Abstract 

Foldable acrylic intraocular lenses (IOLs) are known to reduce posterior capsule opacification by preventing migration of lens epithelial cells with its square edge design and its property of tackiness. Studies have reported a mean adhesiveness to posterior capsule more than three times higher for certain acrylic foldable IOLs than polymethyl methacrylate IOLs. The authors would like to report two cases where the force of tackiness was compensated, thereby presenting with delayed accumulation of lens material in the capsular bags behind the IOL with temporary loss of vision.

Keywords: Foldable, posterior capsule opacification, phacoemulsification


How to cite this article:
Bhattacharjee H, Bhattacharjee K, Bhattacharjee P. Delayed accumulation of lens material behind the foldable intraocular lens. Indian J Ophthalmol 2007;55:472-5

How to cite this URL:
Bhattacharjee H, Bhattacharjee K, Bhattacharjee P. Delayed accumulation of lens material behind the foldable intraocular lens. Indian J Ophthalmol [serial online] 2007 [cited 2024 Mar 19];55:472-5. Available from: https://journals.lww.com/ijo/pages/default.aspx/text.asp?2007/55/6/472/36490

Hydrophobic acrylic lens material (AcrySof ® , Alcon, Fortworth, Texas, USA) is believed to have a strong adhesive property with capsular bag. [1],[2] But the strength of this adhesion in vivo is not exactly known. The authors report two cases where regenerated cortical lens material descended in clumps in the plane between the posterior capsule and the intraocular lens (IOL) probably overcoming the adhesive force between the two. Such a complication has not been reported earlier.


  Case Reports Top


Case 1

A 61-year-old diabetic gentleman, with high myopia and posterior subcapsular cataract in both eyes, underwent uneventful phacoemulsification with in-the-bag IOL implantation (AcrySof® Alcon, Fort Worth, Texas, USA; Model: MA30BA, Power: 12D, Length: 12.5 mm, Optic: 5.5 mm, SN: 506409.091) in both eyes The postoperative period was unremarkable and best corrected visual acuity (BCVA) was 20/20, N6 achieved in both eyes independently.

The patient returned after four years with the complaint of sudden blurring of vision in the left eye. On examination, BCVA in the affected eye was 20/80. Slit-lamp evaluation revealed a quiet anterior segment with presence of conglomerated whitish fluffy material as well as crystalline bodies of different sizes [Figure - 1],[Figure - 2] in the capsular bag behind the IOL covering almost the entire pupillary area in the left eye. A well-developed Soemmering's ring was appreciated in the periphery of the capsular bag beyond the IOL optic after mydriasis. The accumulated material was gravity-dependent and was moving minimally along with eye movement. A clinical diagnosis of delayed accumulation of regenerated cortical lens material was made. It was believed that the equatorial regenerating cortical matter from the superior fornix of the capsular bag got dislodged and gravitated down behind the IOL. The patient was advised lavage of the capsular bag (with histopathological examination of the material) but he refused to undergo any surgical intervention and was therefore kept on regular follow-up without any medications. On subsequent checkups it was noted that the material in the capsular bag behind the IOL was spontaneously decreasing and at the end of a one-year period, the visual axis cleared with BCVA of 20/30. The posterior capsule was clear and there was slow absorption of the material.

Case 2

A 50-year-old gentleman reported with nuclear sclerosis and posterior subcapsular cataract in both eyes and underwent routine uneventful phacoemulsification with in-the-bag IOL implantation in both eyes (AcrySof ® Alcon, Fort Worth, Texas, USA; Model: MA30BA, Power: +23.0 D, Length: 12.5 mm, Optic: 5.5 mm, SN: 516960.070). The postoperative period was unremarkable and with a BCVA of 20/20, N6 both eyes. Seven years following the surgery, he returned with an interesting history of sudden dimness of vision in the left eye, which lasted for a period of few months followed by spontaneous recovery. This temporary visual impairment was characteristic; as if a screen descended from above with clouding of vision followed by spontaneous clearance in the same order. His corrected vision in the affected eye was 20/20. Slit-lamp examination revealed a quiet eye with normal intraocular pressure. Slit-lamp examination after mydriasis revealed whitish fluffy material inferiorly, trapped between the IOL and the posterior capsule (similar to that described in Case 1) encircling 360° with regenerative lens material (Soemmering's ring) beyond the IOL optics. Further noteworthy was the proximity between the haptic and optic, indicating capsular fibrosis and loss in memory of the IOL haptics [Figure - 3],[Figure - 4]. Similar to Case 1, it was also diagnosed as accumulation of regenerated lens material which dislodged from the superior fornix of the capsular bag. As there was no visual impairment, the patient refused any intervention and was under regular observation till the last checkup which showed total absorption of the lens matter. The posterior capsule was maintaining clarity and was noted to be separated from the posterior surface of the IOL [Figure - 5].


  Discussion Top


Acrylic polymer material of AcrySof® IOL is reported to have a tacky surface. The posterior as well as the anterior capsule remain adherent to the lens surface after implantation in the bag [3],[4],[5] and prevent posterior capsular opacification (PCO), capsular fibrosis and lens decentration. Nagata and co-authors [5] reported a mean adhesiveness of 2.76 gw for AcrySof® , making it more than three times higher adhesive than polymethyl methacrylate (0.81 gw) with lens capsule. Nishi and Nishi, in Japan, have published evidence [6] that a square-edge design of an IOL creates a discontinuous capsule bend angle and retards the migration of equatorial lens epithelial cells onto the posterior capsule, resulting in posterior capsular adherence to the posterior surface of the IOL. Design factors such as posteriorly angulated haptics, size and posterior convexity of the optic and tackiness of the surface of IOL enhance the opportunity for the capsular bend to occur. [7] Investigators have concluded that the property of adhesiveness of acrylic IOLs to the capsular bag contributed significantly to the edge design in creating this discontinuous bend and, therefore, in decreased PCO with AcrySof® IOL. [8]

In pursuance of their 'sandwich theory', [9] Linnola et al. have also concluded that the sandwich structure of IOL/1 cell layer/capsule was observed with a significantly higher incidence in association with the AcrySof® IOL and fibrinectin was identified as the extra-cellular protein involved in the formation of this structure. [10],[11]

In the present report, both the cases underwent standard, uneventful, phacoemulsification with in-the-bag posterior chamber IOL implantation after an intact continuous curvilinear capsulorhexis (CCC), with the CCC margin covering the anterior surface of the optic with a minimal overlap. The ring of Soemmering from the capsule epithelium develops postoperatively in course of time and normally it does not dislodge as both anterior and posterior capsules are in strong adherence due to fibrosis. However, in these two cases, probably a plaque from the superior portion of this ring dislodged and descended inferiorly through the retrolenticular space negating the force of tackiness between the IOL and the posterior capsule. During the course of its descent downwards, there was impairment of vision so long as the material was in the visual axis. The tissue pressure inside the ring of Soemmering was considered to be higher to overcome the force of tackiness and this suggests there is a limitation of tackiness which might not have any considerable role in maintaining the clarity of the posterior capsule. Unlike capsular bag distension syndrome, there was evidence of slow absorption of material. In both the situations, it was suspected that the in vivo tackiness of the AcrySof® IOL to the posterior capsule may not be as firm as that reported in in vitro studies. The authors did not come across any other report of a similar nature. However, chemical analysis and microscopic study of the accumulated material could clearly explain its nature which was not possible in these cases.

 
  References Top

1.
Neuhann TH, Weber S. Klinische 12-Monatsergebnisse der Faltbaren, Hydrophoben Acryllinse AMO AR40NB. Klin Monatsbl Augenheilkd 1999;215:329-33.  Back to cited text no. 1
[PUBMED]    
2.
Hollick EJ, Spalton DJ, Ursell PG, Pande MV. Lens epithelial cell regression on the posterior capsule with different intraocular lens materials. Br J Ophthalmol 1998;82:1182-8.  Back to cited text no. 2
[PUBMED]  [FULLTEXT]  
3.
Hollick EJ, Spalton DJ, Ursell PG, Pande MV, Barman SA, Boyce JF, et al . The effect of polymethylmethacrylate, silicone and polyacrylic intraocular lenses on posterior capsular opacification 3 years after cataract surgery. Ophthalmology 1999;106:49-55.  Back to cited text no. 3
[PUBMED]  [FULLTEXT]  
4.
Linnola RJ, Werner L, Pandey SK, Escobar-Gomez M, Znoiko SL, Apple DJ. Adhesion of fibronectin, vitronectin, laminin and collagen type IV to intraocular lens materials in pseudophakic human autopsy eyes Part 2: Explanted intraocular lenses. J Cataract Refract Surg 2000;26:1807-18.  Back to cited text no. 4
[PUBMED]  [FULLTEXT]  
5.
Nagata T, Minakata A, Watanabe I. Adhesiveness of AcrySof to a collagen film. J Cataract Refract Surg 1998;24:367-70.  Back to cited text no. 5
[PUBMED]    
6.
Nishi O, Nishi K. Preventing posterior capsule opacification by creating a discontinuous sharp bend in the capsule. J Cataract Refract Surg 1999;25:521-6.  Back to cited text no. 6
[PUBMED]  [FULLTEXT]  
7.
Nishi O, Nishi K. Effect of the optic size of a single-piece acrylic intraocular lens on posterior capsule opacification. J Cataract Refract Surg 2003;29:348-58.  Back to cited text no. 7
[PUBMED]  [FULLTEXT]  
8.
Nishi O, Nishi K, Sakanishi K. Inhibition of migrating lens epithelial cells at the capsular bend created by the rectangular optic edge of a posterior chamber intraocular lens . Ophthalmic Surg Lasers 1998;29:587-94.  Back to cited text no. 8
[PUBMED]    
9.
Linnola RJ. Sandwich theory: Bioactivity-based explanation for posterior capsule opacification. J Cataract Refract Surg 1997;23:1539-42.  Back to cited text no. 9
[PUBMED]    
10.
Linnola RJ, Salonen JI, Happonen RP. Intraocular lens bioactivity tested using rabbit corneal tissue bultures. J Cataract Refract Surg 1999;25:1480-5.  Back to cited text no. 10
[PUBMED]  [FULLTEXT]  
11.
Linnola RJ, Sund M, Ylonen R, Pihlajaniemi T. Adhesion of soluble fibronectin, laminin and collagen type IV to intraocular lens materials. J Cataract Refract Surg 1999;25:1486-91.  Back to cited text no. 11
    


    Figures

  [Figure - 1], [Figure - 2], [Figure - 3], [Figure - 4], [Figure - 5]


This article has been cited by
1 Visual Acuity in Patients Having Foldable and Non-foldable Intra-ocular Lens for Cataract Surgery
Raiyawa, S. and Samaiporn, S. and Sirikul, S. and Jenchitr, W. and Yenjitr, C. and MA, BE and BSc, M.T.
J Med Assoc Thai. 2008; 91(1): S102-10
[Pubmed]



 

Top
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
Abstract
Case Reports
Discussion
References
Article Figures

 Article Access Statistics
    Viewed3275    
    Printed76    
    Emailed1    
    PDF Downloaded266    
    Comments [Add]    
    Cited by others 1    

Recommend this journal