• Users Online: 5731
  • Home
  • Print this page
  • Email this page
REVIEW ARTICLE
Year : 2008  |  Volume : 56  |  Issue : 6  |  Page : 453-458

Sutureless vitrectomy


1 Retina Unit, South Australian Institute of Ophthalmology and Discipline of Ophthalmology and Visual Sciences, University of Adelaide, South Australia
2 Retina Unit, South Australian Institute of Ophthalmology and Discipline of Ophthalmology and Visual Sciences, University of Adelaide, South Australia; Centre for Sight, New Delhi, India

Correspondence Address:
Rajeev Jain
Centre for Sight, B-5/24, Safdarjung Enclave, New Delhi - 110029

Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0301-4738.43364

Rights and Permissions

Sutureless vitrectomy has rapidly been accepted as an essential part of a vitreoretinal surgical setup. The size and structure of the wound along with near intact conjunctival covering makes the incision self-sealing and safe. This allows the vitrectomy instruments to be used without creating an initial limited peritomy to expose bare sclera, and obviates the need for sutures at the end of the procedure. Wound construction is the essential step in ensuring postoperative wound stability. Both one-step and two-step wound constructions have been described. Key points include an oblique, tunneled approach to ensure a valve-like effect as well as misalignment of conjunctival and scleral wounds by displacing conjunctiva during construction. Advantages include decreased operative times in certain cases and decreased postoperative inflammation, early postoperative rehabilitation, improved patient comfort, and minimal conjunctival damage. Complications are based around wound competence, hypotony, and its relationship to endophthalmitis rates. Early reports highlighted an increase in endophthalmitis though further studies are required to accurately assess the incidence. Endophthalmitis has not been reported in cases that underwent fluid/air exchange. This review focuses on techniques, benefits, complications, personal experiences, and the safety profiles of sutureless vitrectomy systems. A literature review was undertaken using 'Medline' and 'Pubmed'. Search terms included sutureless vitrectomy, 20 gauge, 23 gauge, 25 gauge, and transconjunctival and small gauge vitrectomy.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed9503    
    Printed157    
    Emailed15    
    PDF Downloaded1033    
    Comments [Add]    
    Cited by others 24    

Recommend this journal