• Users Online: 1311
  • Home
  • Print this page
  • Email this page

   Table of Contents      
LETTER TO THE EDITOR
Year : 2013  |  Volume : 61  |  Issue : 9  |  Page : 531-532

Eat the pie or imbibe the ribbon: An epochal moment at the crossroads of mechanized cataract surgery


1 Department of Ophthalmology, Hindu Rao Hospital, Delhi, India
2 Department of Medicine, Jag Pravesh Chandra Hospital, Delhi, India

Date of Web Publication8-Oct-2013

Correspondence Address:
Bali Jatinder
55-D, Third Floor, DDA FLATS, Kalidas Road, Gulabibagh, Delhi - 110 007
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0301-4738.119460

Rights and Permissions

How to cite this article:
Jatinder B, Thakur BR. Eat the pie or imbibe the ribbon: An epochal moment at the crossroads of mechanized cataract surgery. Indian J Ophthalmol 2013;61:531-2

How to cite this URL:
Jatinder B, Thakur BR. Eat the pie or imbibe the ribbon: An epochal moment at the crossroads of mechanized cataract surgery. Indian J Ophthalmol [serial online] 2013 [cited 2023 Dec 6];61:531-2. Available from: https://journals.lww.com/ijo/pages/default.aspx/text.asp?2013/61/9/531/119460

Dear Editor,

The femtosecond laser lens fragmentation (LLF) has opened new vistas for decreasing the energy used in removing cataracts. Batlle et al., have reported a decrease of 40% in the cumulative dispersive energy (CDE) for phacoemulsification in their study comparing non-laser assisted manual phacoemulsification (18.9 s) with laser lens fragmentation (LLF) assisted phacoemulsification (11.6 s). [1] Edwards et al., have shown that the decrease in CDE was related to nuclear density with a reduction of 100% for grade 1 nuclear cataract, 64% for grade 2, 39% for grade 3, and 42% for grade 4 cataracts. The study used pie-cut method of LLF disassembly. [2]

Customizable LLF algorithms can be programmed on the femtosecond laser platform software. The developments on microsensors and controlling chips are already advanced enough to allow for precise control of pressure changes in medium flow systems. Given the current developments and the fact that the phacoemulsification systems today routinely use 3.2 or 2.8 mm entry ports, the need for using phacoemulsification with LLF would become redundant if the nucleus were to be fragmented in ribbon shapes [Figure 1]. The pie is unevenly shaped and is not suited to aspiration with a narrow and a very broad end. Our experience with the phacoemulsification machines has brought us to the point where we are comfortable with much higher vacuum pressures than, say, 2 decades ago. If power mode were to be dispensed within favor of a divided flow system and pure aspiration mode with chop being the preferred modality for preaspiration completion of lens fragmentation; then the 2.8 mm incision or even smaller incision with narrower ribbon blocks can remove the cataract with aspiration alone without any need for ultrasonic power delivery inside the eye.
Figure 1: Aspiration through 3.2 mm incision with larger aspiration port using ribbon laser lens fragmentation (LLF) and chop parameters. The irrigation is through side port entry in the divided system for better chamber stability

Click here to view


Increasing the bore of aspiration port increases the effective vacuum (or holding power) and decreases rise time in the system. All this necessitates the use of a high inflow system and use of microsensors for fluidic control monitoring vacuum at level of handpiece itself to guard against sudden decompression. This brings down the cost of peripheral system. Thus, the capital and running cost of femtosecond platform become the main limiting parameters in the economic consideration.

Are we looking at an age without the ubiquitous "ultrasonic phaco"? Only time can tell, whether or when these random musings will become a reality. However, one thing is sure. This is truly an epochal moment at the crossroads for mechanized cataract surgery.

 
  References Top

1.
Batlle JF, Feliz R, Culbertson WW. OCT guided femtosecond laser cataract surgery: Precision and accuracy. Association for research in Vision and Ophthalmology Annual Meeting: A4694 Poster #D633. Fort Lauderdale, Florida, 2011. Available from: http://www.arvo.org [Last accessed on 2011 Dec 29].  Back to cited text no. 1
    
2.
Edwards K, Uy HS, Schneider S. The effect of laser lens fragmentation on use of ultrasound energy in cataract surgery. Association for research in Vision and Ophthalmology Annual Meeting: A4710 Poster #D768. Fort Lauderdale, Florida, 2011. Available from: http://www.arvo.org [Last accessed on 2011 Dec 29].  Back to cited text no. 2
    


    Figures

  [Figure 1]



 

Top
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
References
Article Figures

 Article Access Statistics
    Viewed1151    
    Printed34    
    Emailed0    
    PDF Downloaded149    
    Comments [Add]    

Recommend this journal