|
|
LETTER TO THE EDITOR |
|
Year : 2013 | Volume
: 61
| Issue : 9 | Page : 534 |
|
Factors having implications on re-retinal detachments after silicone oil removal
Manish P Nagpal, Rituraj P Videkar, Kamal M Nagpal
Retina Foundation and Asopalav eye Hospital, Shahibaug, Ahemedabad, India
Date of Web Publication | 8-Oct-2013 |
Correspondence Address: Manish P Nagpal Retina Foundation and Asopalav Eye Hospital, Near Shahibaug Underbridge, Shahibaug, Ahmedabad, Gujarat India
 Source of Support: None, Conflict of Interest: None  | Check |
DOI: 10.4103/0301-4738.119463
How to cite this article: Nagpal MP, Videkar RP, Nagpal KM. Factors having implications on re-retinal detachments after silicone oil removal. Indian J Ophthalmol 2013;61:534 |
Dear Editor,
We thank the readers for their interest and valuable comments in response to our article. We agree with the reader that two-port approach for silicone oil removal is less invasive, but hardly gives any control to the surgeon over evaluating the retinal status during the procedure. Sometimes a retinal detachment is encountered intraoperatively after silicone oil removal due to a pre-existing hidden break or reopening of the pre-existing break, [1] which until then was/were tamponade by silicone oil. We follow the three-port approach so as to tackle such an eventuality in addition to the obvious indication of laser augmentation or epiretinal membrane removal as suggested by the reader. The small gauge vitrectomy systems further reduce the chances of conjunctival scarring and can hardly be called invasive and we strongly recommend use of a three-port vitrectomy for oil removal instead of a two-port, which gives the surgeon very little on table control over checking the retinal status and can take corrective measure if required.
This study which was aimed at studying the relation between retinal re-detachment following silicone oil removal and its relation with the encirclage, laser retinopexy, duration of tamponade, emulsification of silicone oil and hence the reasons of retinal detachment such as opening of retinal break due to proliferative vitreoretinopathy (PVR) and instrument touch was out of the scope of the study. PVR is anyways present in most cases where silicon oil is injected and is an important factor anyways for any sort of recurrence of re-detachment whatsoever. We do agree that for studying the reasons of retinal detachment due to various variables a broader randomised trial would be required.
We agree with the reader that difference in densities of silicone oil can affect the results and would like to congratulate the reader for their excellent observation; however, we would like to clarify that we had used only 1000 centistokes of silicone oil in all the cases. We have addressed this issue in our review article on silicone oil removal. [2]
It is an excellent suggestion to compare the average duration of oil removal in emulsified and no emulsified group and we would be happy to look at that aspect in a future study.
References | |  |
1. | Hutton WL, Azen SP, Blumkranz MS, Lai MY, McCuen BW, Han DP, et al. The effects of silicone oil removal. Silicone study report 6. Arch Ophthalmol 1994;112:778-85. |
2. | Nagpal M, Videkar R. Silicone oil Removal. Expert Rev Ophthalmol 2012;7:87-96. |
This article has been cited by | 1 |
Macular changes after primary retinectomy for retinal detachment complicated by proliferative vitreoretinopathy |
|
| Piergiacomo Grassi, David Charteris | | Clinical and Experimental Optometry. 2023; : 1 | | [Pubmed] | [DOI] | | 2 |
A Prediction Nomogram for Recurrent Retinal Detachment |
|
| Yongying Zhou, Qianyi Lu, Zhigang Chen, Peirong Lu | | Risk Management and Healthcare Policy. 2023; Volume 16: 479 | | [Pubmed] | [DOI] | | 3 |
STRUCTURAL AND FUNCTIONAL MACULAR CHANGES AFTER RETINECTOMY FOR RETINAL DETACHMENT COMPLICATED BY PROLIFERATIVE VITREORETINOPATHY |
|
| Piergiacomo Grassi, Saffron Melville, Anu-Sree Hariprasad, Stephen Winder, Yashin Ramkissoon, Kurt Spiteri-Cornish, Raquel G. Cabrera, Siddharth Subramani, Anand Chawla | | Retina. 2021; 41(12): 2531 | | [Pubmed] | [DOI] | | 4 |
Retinal electrophysiological changes related to early versus late silicone oil removal |
|
| Haitham Y. Al-Nashar, Sherif A. Dabbour, Mohammed A. Alnaimy | | International Ophthalmology. 2021; 41(12): 4075 | | [Pubmed] | [DOI] | | 5 |
Management of recurrent rhegmatogenous retinal detachment |
|
| Manish Nagpal, Pranita Chaudhary, Shachi Wachasundar, Ahmed Eltayib, Aparajita Raihan | | Indian Journal of Ophthalmology. 2018; 66(12): 1763 | | [Pubmed] | [DOI] | |
|
 |
 |
|