  Abstract 

Purpose: This study aimed to evaluate the alignment pattern of the graft–host junction after penetrating keratoplasty (PK) by anterior segment-optical coherence tomography (AS-OCT) and to correlate this pattern with the magnitude of postoperative astigmatism. Methods: This retrospective observational study was carried out on forty patients who underwent PK from February 2013 to August 2014. AS-OCT was performed, and the graft–host junctions were classified into well-apposed junction, malapposed junction, and equally apposed junction. Mal-apposition is subdivided into gap and protrusion. The correlations between clinical characteristics, wound profiles from the AS-OCT, and the magnitude of postoperative astigmatism by Sirius camera (Costruzione Strumenti Oftalmici [CSO], Florence, Italy (CSO, Sirius), were analyzed. Results: Graft–host junctions from forty patients were analyzed; 18 eyes had well-apposed junctions, ten eyes had malapposed junctions, and 12 had equally apposed junctions. The mean cylinder was −9.44 ± −4.00D in well-apposed group, −13.40 ± −5.01D in malapposed group, and −4.67 ± −0.94D in equally apposed group. Alignment pattern of the graft–host junction correlated significantly with the magnitude of astigmatism (P = 0.034). Preoperative corneal diseases did not have an effect on the magnitude of astigmatism (P = 0.123). Conclusion: The alignment pattern of the graft–host junction by AS-OCT can explain the postoperative astigmatism after PK where it correlates significantly with the magnitude of astigmatism.

Keywords: Anterior segment-optical coherence tomography, corneal topography, graft–host junction, penetrating keratoplasty, postoperative astigmatism


How to cite this article:
Nassar GA, Arfeen SA. Correlation between the graft–host junction of penetrating keratoplasty by anterior segment-optical coherence tomography and the magnitude of postoperative astigmatism. Indian J Ophthalmol 2017;65:574-8

How to cite this URL:
Nassar GA, Arfeen SA. Correlation between the graft–host junction of penetrating keratoplasty by anterior segment-optical coherence tomography and the magnitude of postoperative astigmatism. Indian J Ophthalmol [serial online] 2017 [cited 2024 Mar 28];65:574-8. Available from: https://journals.lww.com/ijo/pages/default.aspx/text.asp?2017/65/7/574/211132

The precise apposition at the graft–host junction is an important goal of penetrating keratoplasty (PK) and is also a prognostic factor affecting the surgical outcome.[1] Postoperative astigmatism still remains an important cause of low vision after PK. Astigmatism after PK can be caused by many factors including misalignment between the graft and host.[2],[3] Hence, evaluation of the graft–host junction is important in the management of post-PK patients.

Owing to the recent development of optical coherence tomography (OCT), high-resolution anterior segment (AS) images can be obtained and applied in the diagnosis of various corneal disorders.[4],[5]

There are few studies that analyzed the wound profile after PK using AS-OCT.[6],[7],[8] In this study, we evaluated alignment pattern of the graft–host junction by AS-OCT and correlated it with the postoperative astigmatism.


  Methods Top


This study was done on forty patients. We retrospectively reviewed the clinical records of patients who underwent PK at Cairo University Hospital from February 2013 to August 2014 and were followed up for more than 1 year. The studied preoperative data included age at the time of surgery, sex, and the preoperative corneal pathology. All patients underwent full ophthalmologic examinations including best-corrected visual acuity (BCVA), refraction, slit-lamp bio-microscopy, intraocular pressure (IOP), evaluation of the graft–host interface using AS-OCT, and evaluation of postoperative astigmatism by Costruzione Strumenti Oftalmici (CSO) topographer.

Patients who had combined surgery such as amniotic membrane transplantation or limbal transplantation were excluded from the study. We also excluded the patients when it was difficult to acquire high-quality images because of poor cooperation.

Surgery was performed by experienced surgeons under general anesthesia. The suturing technique consisted of 16–18 bite interrupted or continuous sutures, according to the surgeon's decision. A 10-0 nylon monofilament suture was used in all cases.

Anterior segment-optical coherence tomography imaging technique

AS-OCT was done using Optovue RTVue model RT100 (Optovue, Inc., Fremont, CA, USA). A corneal adopter module which produced telecentric scanning for AS imaging using either a wide-angle or high-magnification adaptor lens was used. Evaluation was performed 1 month after all corneal sutures were removed. The patients were asked to look straight at a fixation target within the device. A single experienced examiner scanned four high-resolution optical sections at 45° interval, showing eight graft–host junctions using raster scan pattern. The scan pattern included 17 parallel line scans, 2–10 mm in length and 1–6 mm in width.

A single trained examiner masked to the clinical data of the patients interpreted the OCT images. Each graft–host interface was categorized according to alignment patterns of the corneal internal side as follows: well-apposed junction if the corneal internal side was aligned precisely without disconnection [Figure 1], gap if the Descemet's membrane and the inner stroma of the donor and recipient were not connected, but were aligned [Figure 2], and protrusion if the Descemet's membrane and the stroma protruded toward the anterior chamber (AC) [Figure 3].
Figure 1: Anterior segment-optical coherence tomography image using raster scan evaluating graft–host junction in the superior quadrant showing precisely aligned corneal internal side without disconnection (well apposition)

Click here to view
Figure 2: Anterior segment-optical coherence tomography image using raster scan evaluating graft–host junction in the inferior quadrant showing disconnected Descemet's membrane and the inner stroma of the graft–host junction (gapping)

Click here to view
Figure 3: Anterior segment-optical coherence tomography image using raster scan evaluating graft–host junction showing protrusion of the stroma and the Descemet's membrane toward the anterior chamber (protrusion)

Click here to view


The distribution of alignment patterns in each section was evaluated. The eyes were classified into the well-apposed junction, malapposed junction, and equally apposed junction according to the most frequent alignment pattern among the eight cross sections. We considered the graft–host junction of the eye as well apposed if more than four sections were aligned precisely without disconnection, malapposed if more than four sections showed gapping or protrusion, and equally apposed if each of the four sections showed the same alignment pattern (four sections are malapposed and the other four sections are well apposed).

We evaluated the graft–host disparity by calculating the corneal thickness difference between the donor and recipient each at a point 1 mm away from a line where the donor and recipient met among the eight cross sections and we calculated the average of them [Figure 4].
Figure 4: Anterior segment-optical coherence tomography image using manual caliber for calculation of the graft–host thickness disparity

Click here to view


Patient age, sex, BCVA by spectacles, IOP, spherical equivalent, postoperative topographic astigmatism, and central corneal thickness were compared between alignment groups. Correlation between the alignment pattern of wound interface and the magnitude of postoperative astigmatism was evaluated.

Corneal astigmatism was evaluated using CSO Sirius topographer (Costruzione Strumenti Oftalmici, Florence, Italy), which uses a combination of a Placido disk and a rotating Scheimpflug camera to measure the anterior and posterior corneal surfaces and the corneal thickness across the whole cornea.

Statistical analysis

Data were coded and entered using the statistical package Statistical Package for the Social Science (SPSS Inc., Chicago, IL, USA) version 22. Data were summarized using mean, standard deviation, and range for quantitative data and using frequency (count) and relative frequency (percentage) for categorical data. Comparisons between quantitative variables were done using the nonparametric Kruskal–Wallis and Mann–Whitney tests. Correlations between quantitative variables were done using Spearman's correlation coefficient. P < 0.05 was considered statistically significant.


  Results Top


Forty patients who fulfilled the inclusion criteria were identified. The mean age of patients at the time of the study was 41.4 ± 13.40 years (range; 16–62 years). The mean spherical equivalent was 2.2 ± 1.66 (range: −2–+ 7.00). The mean postoperative flatter corneal meridian was 32.85 ± 2.56 D. The mean postoperative steeper corneal meridian was 41.95 ± 6.89 D. The mean astigmatic error was − 9.00 ± −4.00 D. The mean IOP was 16.65 ± 2.32 mmHg, and the mean central corneal thickness was 528.75 ± 46.77 μm.

The indications of PK were bullous keratopathy (four eyes, 10%), corneal dystrophy (two eyes, 5%), keratoconus (six eyes, 15%), leukoma adherent (four eyes, 10%), and leukoma nonadherent (24 eyes, 60%).

There were no statistically significant differences in age, BCVA by spectacles, spherical equivalent, postoperative astigmatism, IOP, and central corneal thickness between different etiological groups [Table 1].
Table 1: Comparison between different corneal diseases

Click here to view


The distribution of the alignment pattern was not significantly different between the preoperative diagnosis groups (P = 0.082). The keratoconus group showed a higher incidence of malapposed junction (66.7%) whereas the most frequent type of alignment pattern in the other groups was well-apposed junction (85% in corneal dystrophy, 60% in bullous keratopathy, and 52% in leukoma group).

Eyes were classified according to the most frequent alignment pattern among the eight cross sections. Eighteen (45%) eyes had well-apposed junctions, 10 (25%) eyes had malapposed junctions, and 12 (30%) had equally apposed junctions. Eyes with malapposed junction were subdivided into four (10%) gapping and six (15%) protrusion.

The mean cylinder was − 9.44 ± −4.45D in well-apposed group, −13.40 ± −5.01D in malapposed group, and −4.67 ± −0.94D in equally apposed group. Alignment pattern of the graft–host junction correlated statistically significantly with the magnitude of astigmatism (P = 0.034) [Figure 5].
Figure 5: Correlation between alignment pattern of the graft–host junction and the magnitude of astigmatism in the different alignment groups

Click here to view


The mean thickness disparity at the wound interface was 44 ± 10.14 μm in well-apposed group, 70 ± 8.58 μm in malapposed group, and 60 ± 12.58 μm in equally apposed group.

We found that the graft–host disparity correlates statistically significantly with the graft–host junction pattern (P = 0.002).

Comparisons of various parameters between the well-apposed group, malapposed group, and equally apposed group were summarized in [Table 2].
Table 2: Comparison of various parameters between the different alignment groups of anterior segment-optical coherence tomography

Click here to view


We found that the more the number of malapposed sections, the higher the magnitude of postoperative astigmatism, however it was statistically insignificant [Table 3].
Table 3: Correlation between the number of malapposed sections per eye and the magnitude of astigmatism

Click here to view


Anterior chamber-angle by anterior segment-optical coherence tomography

The angle of the AC was evaluated. It was open in 28 eyes (70%). There was peripheral anterior synechiae (PAS) in 12 eyes (30%). All patients with PAS had normal IOP. There was no statistically significant difference between both groups (P = 0.473).


  Discussion Top


Corneal astigmatism after PK is a common complication that can prevent a good visual outcome in an eye with a clear graft and an otherwise healthy visual system. It arises from many causes related to the recipient cornea:[9] trephination of the donor material, trephination of the recipient bed, suturing of the donor cornea to the recipient bed, excessive or uneven suture tension, graft–host misalignment, and irregular wound healing.[10],[11],[12]

It is easy to detect external misalignment during surgery. However, external misalignment does not mean necessarily that the inner edges of the wound are well apposed; in many cases, the endothelial side is not well apposed.[6],[7] With the development of AS-OCT as an important modality for evaluation of the different corneal conditions, the graft–host junction could be evaluated easily.

In a study done by Kaiserman et al. on 27 eyes, they reported that the internal graft–host malapposition is relatively common and associated with increased astigmatism and IOP, and they also found that keratoconus patients had significantly more graft steps. They also reported that graft oversizing increased the size of malapposition, while the internal gapes or steps significantly reduced graft–host touch. They handled the eight images obtained from each eye as eight different data, so it is inconclusive whether the statistical results are really significantly different.[6]

Jhanji et al. also conducted a similar study and categorized the alignment pattern into the two groups, step and ledge. Since they did not evaluate the characteristics of each alignment group, it was difficult to know whether the alignment pattern after PK affects the postoperative outcome or not.[7]

Sung et al. conducted a similar study and evaluated the wound profile of post-PK eyes and the factors related to the wound alignment pattern. The alignment pattern of wound interface after PK differed according to the clinical diagnosis and was significantly associated with spherical equivalent and keratometric astigmatism.[8]

In our study, we evaluated the wound profile of postkeratoplasty eyes using AS-OCT and correlated its pattern with the postoperative refractive and topographic astigmatism.

We found, similar to the previous reports, that among the malapposed junctions, protrusion was the most common misalignment type as it represented 60% of malapposed junction group. The result might be explained by the curling up of large donor on the wound interface. In addition, the tendency for stromal overgrowth induced by incomplete contact between the donor and recipient may affect the wound profile.[8],[13]

In contrast to the previous reports,[6],[8] the distribution of the alignment pattern was not statistically significantly different between the preoperative diagnosis groups (P = 0.082). However, the keratoconus group showed a higher incidence of malapposed junction (66.7%) which is similar to the other studies. This can be explained by the thickness mismatch between the thin peripheral part of recipient cornea and thick donor graft.

Thickness disparity at the wound interface was statistically significantly different between the alignment groups (P = 0.002). It was lowest in the well-apposed group and highest in the malapposed group.

Similar to the previous report,[8] we found statistically significant difference in the postoperative astigmatism between different alignment groups. The malapposed group showed statistically significant higher mean astigmatic error than that of the other groups (P = 0.034), while the equally apposed group showed the least mean astigmatic error. This might be explained by the presence of equal sections of both malapposed and well-apposed junctions which might neutralize the effect of each other.

However, we did not find statistically significant difference in the spherical equivalent between the different alignment groups as other factors rather than the influence of astigmatism such as the axial length and lens status might have affected the spherical equivalent (P = 0.652).

Regarding topographic astigmatism, our results suggested that the alignment state has significant effect on cylindrical power. We used Scheimpflug keratometer (CSO, Sirius) in the assessment of postkeratoplasty astigmatism to get more accurate correlation, while previous studies used manual keratometer whose range of measurements is limited within 3 mm of the central cornea and does not include the posterior corneal surface.

Our study has several limitations. Our study population had patients with selected underlying diseases and the number of patients in each group was relatively small, thus the results may not be applicable to all post-PK cases. In addition, we did not exclude the effect of the degree of graft oversize as not all the eyes had the same degree of graft oversize and this might have had effect on the results. We recommend a large-scale study on various preoperative clinical diagnoses to understand the alignment patterns of the wound interface after PK.


  Conclusion Top


The alignment pattern of the graft–host junction by AS-OCT can explain the postoperative astigmatism after PK where it correlates significantly with the magnitude of astigmatism.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 
  References Top

1.
Morrison JC, Swan KC. Descemet's membrane in penetrating keratoplasties of the human eye. Arch Ophthalmol 1983;101:1927-9.  Back to cited text no. 1
    
2.
Farid M, Kim M, Steinert RF. Results of penetrating keratoplasty performed with a femtosecond laser zigzag incision initial report. Ophthalmology 2007;114:2208-12.  Back to cited text no. 2
    
3.
Binder PS. The effect of suture removal on postkeratoplasty astigmatism. Am J Ophthalmol 1988;105:637-45.  Back to cited text no. 3
    
4.
Jancevski M, Foster CS. Anterior segment optical coherence tomography. Semin Ophthalmol 2010;25:317-23.  Back to cited text no. 4
    
5.
Ramos JL, Li Y, Huang D. Clinical and research applications of anterior segment optical coherence tomography – A review. Clin Exp Ophthalmol 2009;37:81-9.  Back to cited text no. 5
    
6.
Kaiserman I, Bahar I, Rootman DS. Corneal wound malapposition after penetrating keratoplasty: An optical coherence tomography study. Br J Ophthalmol 2008;92:1103-7.  Back to cited text no. 6
    
7.
Jhanji V, Constantinou M, Beltz J, Vajpayee RB. Evaluation of posterior wound profile after penetrating keratoplasty using anterior segment optical coherence tomography. Cornea 2011;30:277-80.  Back to cited text no. 7
    
8.
Sung MS, Yoon KC. Evaluation of graft-host interface after penetrating keratoplasty using anterior segment optical coherence tomography. Jpn J Ophthalmol 2014;58:282-9.  Back to cited text no. 8
    
9.
Olson RJ. Prevention of astigmatism in corneal transplant surgery. Int Ophthalmol Clin 1988;28:37-45.  Back to cited text no. 9
    
10.
Mahjoub SB, Au YK. Astigmatism and tissue-shape disparity in penetrating keratoplasty. Ophthalmic Surg 1990;21:187-90.  Back to cited text no. 10
    
11.
Girard LJ, Eguez I, Esnaola N, Barnett L, Maghraby A. Effect of penetrating keratoplasty using grafts of various sizes on keratoconic myopia and astigmatism. J Cataract Refract Surg 1988;14:541-7.  Back to cited text no. 11
    
12.
Musch DC, Meyer RF, Sugar A, Soong HK. Corneal astigmatism after penetrating keratoplasty. The role of suture technique. Ophthalmology 1989;96:698-703.  Back to cited text no. 12
    
13.
Garner A. Corneal wound healing. In: Casey TA, Mayer DG, editors. Corneal Grafting. Philadelphia: Saunders; 1984. p. 27-34.  Back to cited text no. 13
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5]
 
 
    Tables

  [Table 1], [Table 2], [Table 3]


This article has been cited by
1 Managing Post-Keratoplasty Astigmatism: High-Tech vs. Low-Tech Imaging Techniques for Guiding Suture Manipulation
Alfredo Borgia, Vito Romano, Davide Romano, Luca Pagano, Aldo Vagge, Giuseppe Giannaccare, Mahmoud Ahmed, Kunal Gadhvi, Nardine Menassa, Mohammad Ahmad, Stephen Kaye, Giulia Coco
Journal of Clinical Medicine. 2023; 12(10): 3462
[Pubmed] | [DOI]
2 Post Penetrating Keratoplasty Astigmatism
Rashmi Deshmukh, Sridevi Nair, Pravin K Vaddavalli, Tushar Agrawal, Christopher J Rapuano, Jacqueline Beltz, Rasik B. Vajpayee
Survey of Ophthalmology. 2021;
[Pubmed] | [DOI]
3 Individualized Corneal Patching for Treatment of Corneal Trauma Combined with Tissue Defects
Ting Zhang, Yanni Jia, Suxia Li, Weiyun Shi, Katarzyna Krysik
Journal of Ophthalmology. 2020; 2020: 1
[Pubmed] | [DOI]



 

Top
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
Abstract
Methods
Results
Discussion
Conclusion
References
Article Figures
Article Tables

 Article Access Statistics
    Viewed2323    
    Printed53    
    Emailed0    
    PDF Downloaded262    
    Comments [Add]    
    Cited by others 3    

Recommend this journal