• Users Online: 33769
  • Home
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2019  |  Volume : 67  |  Issue : 9  |  Page : 1410-1416

Gas permeable contact lens fitting in keratoconus: Comparison of different guidelines to back optic zone radius calculations


1 Universidad de Valladolid, Departamento de Física Teórica, Atómica y Óptica, Valladolid, España; Universidad de Valladolid, Instituto Universitario de Oftalmobiología Aplicada (IOBA), Valladolid, España; Optometry Research Group, IOBA Eye Institute, School of Optometry, University of Valladolid, Valladolid, Spain
2 Optometry Research Group, IOBA Eye Institute, School of Optometry, University of Valladolid, Valladolid; Department of Ophthalmology, Ramón y Cajal University Hospital, Madrid, Spain
3 Universidad de Valladolid, Departamento de Física Teórica, Atómica y Óptica, Valladolid, España; Universidad de Valladolid, Instituto Universitario de Oftalmobiología Aplicada (IOBA), Valladolid, España; Optometry Research Group, IOBA Eye Institute, School of Optometry, University of Valladolid, Valladolid, Spain; Faculty of Health and Human Sciences, Plymouth University, Plymouth, United Kingdom

Correspondence Address:
Dr. Raul Martin
School of Health Professions, Faculty of Health and Human Sciences, Plymouth University, Peninsula Allied Health Centre, Derriford Road, Plymouth, PL6 8BH, UK and Optometry Research Group, IOBA Eye Institute, School of Optometry (University of Valladolid), Valladolid

Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijo.IJO_1538_18

Rights and Permissions

Purpose: Compare the agreement between the finally fitted back optic zone radius (BOZR) of a spherical gas permeable (GP) contact lense (CL) with those proposed by different guidelines currently available to fit GP CLs in keratoconus. Methods: The BOZR fitted in 81 keratoconus eyes (46 patients) were recorded and compared with the BOZR calculated with ten different guidelines (identified after a literature review) proposed to calculate the first diagnostic lens BOZR to be fitted in keratoconus. Arithmetic and absolute mean difference between both BOZR were calculated (paired t-test). The success rate of each guideline (difference between both BOZR ≤0.05 mm) was calculated for different keratoconus stages (Amsler–Krumeich classification). Agreement between BOZR was evaluated using Bland-Altman analysis. Results: The BOZR proposed by all guidelines correlated with the final BOZR that was fitted (R2 > 0.71; P < 0.01). A statistically significant difference was found between the BOZR suggested by all guidelines and the BOZR that was prescribed (P < 0.05), except for three Guidelines (P ≥ 0.11). CALCULENS.com presented the best agreement (mean difference of 0.00 ± 0.12 mm), and 50.6% of cases showed ≤0.05 mm of difference with the BOZR that was fitted. However, the worst guideline showed an agreement of −0.38 ± 0.22 mm, and just 3.8% of cases had ≤0.05 mm of difference with the final fitted BOZR. Conclusion: BOZR calculated with most of the analyzed guidelines shows statistical differences with final fitted BOZR, suggesting a lack of clinical validation of these guidelines. The selection of the BOZR with CALCULENS.com could provide a better starting point for spherical GP CL fitting in keratoconus eyes.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2469    
    Printed45    
    Emailed0    
    PDF Downloaded265    
    Comments [Add]    
    Cited by others 2    

Recommend this journal