Year : 2020  |  Volume : 68  |  Issue : 10  |  Page : 2221-2222

What lies beneath: Posterior capsular imaging in posterior polar cataracts


1 Department of Cataract & Refractive Surgical Sciences, Centre For Sight, New Delhi, India
2 Department of Cataract & Refractive Surgical Sciences, The Eye Foundation, Coimbatore, Tamil Nadu, India

Date of Submission11-Feb-2020
Date of Acceptance17-Apr-2020
Date of Web Publication23-Sep-2020

Correspondence Address:
Dr. Mahipal S Sachdev
Centre for Sight, B 5/24, Safdarjung Enclave, New Delhi - 110 029
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijo.IJO_283_20

Rights and Permissions
  Abstract 


Keywords: Anterior segment optical coherence tomography, ASOCT, posterior capsule, posterior polar cataract


How to cite this article:
Sachdev MS, Malik R, Gupta H, Narula R, Sachdev GS. What lies beneath: Posterior capsular imaging in posterior polar cataracts. Indian J Ophthalmol 2020;68:2221-2

How to cite this URL:
Sachdev MS, Malik R, Gupta H, Narula R, Sachdev GS. What lies beneath: Posterior capsular imaging in posterior polar cataracts. Indian J Ophthalmol [serial online] 2020 [cited 2020 Oct 31];68:2221-2. Available from: https://www.ijo.in/text.asp?2020/68/10/2221/295732



This study adhered to the tenets of Declaration of Helsinki, ethics committee clearance was obtained and written informed consent was taken. A 52-year-old male presented with complaints of defective vision in the right eye since one year. Corrected distance visual acuity was 20/80 and 20/40 in the right and left eye, respectively. Slit lamp bio microscopic evaluation revealed a dense posterior polar cataract (PPC) with apparent equator-to equator discontinuity of the posterior capsule (PC) in the right eye [Figure 1]. Left eye demonstrated an early cataract.
Figure 1: Slit lamp image of the crystalline lens showing a posterior polar cataract. A spindle-shaped posterior capsular defect is seen around the polar opacity

Click here to view


Swept-source OCT in the IOL Master-700 (Zeiss Medical, Germany) revealed an irregular and discontinuous PC [Figure 2]. Femtosecond laser assisted cataract surgery with intraocular lens implantation was advised for the right eye. The built-in ASOCT in the Catalys Platform (Johnsons and Johnsons Vision, USA) demonstrated a clear discontinuity of the PC. The system additionally enables the surgeon to adjust the posterior laser offset, leaving a thick epinuclear layer behind, which protects the PC from mechanical and hydraulic turbulence during phacoemulsification [Figure 3].[1]
Figure 2: IOL Master 700 Swept source OCT of the crystalline lens showing a bumpy and irregular posterior capsule with discontinuity

Click here to view
Figure 3: Femtosecond laser integrated OCT demonstrating discontinuity of the posterior capsule (arrow) and increased posterior laser offset (arrowhead) of 1000 microns

Click here to view


The microscope-integrated OCT (MIOCT) (Rescan 700, ZEISS, Germany) showed an intraoperative preexisting break in the PC with herniation of cortical matter in the anterior vitreous [Figure 4]. Cataract extraction was completed maintaining a closed chamber technique and low parameter fluidics. A discontinuity of the PC with a dome-shaped forward herniation of anterior vitreous face was seen [Figure 5].
Figure 4: MIOCT Showing an obvious PC defect, and possible herniation of cortical matter into the anterior vitreous

Click here to view
Figure 5: MIOCT scan taken after nuclear emulsification showing a discontinuity of the PC, and a dome-shaped anteriorly herniating blob of vitreous (arrow)

Click here to view



  Discussion Top


Imaging of the PC using adjunctive tools allows differentiation of a true PPC from a pseudo-polar opacity in doubtful cases following slit lamp evaluation.[2] Additional information regarding the presence and size of PC discontinuity better prepares a surgeon regarding the increased risk of vitreous loss. Imaging modalities additionally delineate subsequent vitreous loss if any and allow optimal management. In conclusion PC imaging allows safe phacoemulsification in PPC, decreasing the risk of rupture from 36% to 0%,[3],[4] with concomitant use of better machines, fluidics, and Femtolaser Assisted cataract Surgery (FLACS).

Declaration of patient consent

The authors certify that they have obtained all appropriate patient consent forms. In the form the patient(s) has/have given his/her/their consent for his/her/their images and other clinical information to be reported in the journal. The patients understand that their names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
  References Top

1.
Sachdev M, Malik R, Gupta H, Sachdev R, Sachdev G. Femtosecond laser-integrated anterior segment optical coherence tomography to detect preexisting posterior capsular dehiscence and increase safety in posterior polar cataracts. Journal of Cataract & Refractive Surgery 2020;46:235-40.  Back to cited text no. 1
    
2.
Das S, Kummelil M, Kharbanda V, Arora V, Nagappa S, Shetty R, et al. Microscope integrated intraoperative spectral domain optical coherence Tomography for cataract surgery: Uses and applications. Curr Eye Res 2015;41:643-52.  Back to cited text no. 2
    
3.
Vasavada A, Singh R. Phacoemulsification in eyes with posterior polar cataract. J Cataract Refractive Surg 1999;25:238-45.  Back to cited text no. 3
    
4.
Titiyal J, Kaur M, Sharma N. Femtosecond laser-assisted cataract surgery technique to enhance safety in posterior polar cataract. J RefractSurg 2015;31:826-8.  Back to cited text no. 4
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5]



 

Top
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
Abstract
Discussion
References
Article Figures

 Article Access Statistics
    Viewed186    
    Printed0    
    Emailed0    
    PDF Downloaded39    
    Comments [Add]    

Recommend this journal