Interconnecting ophthalmic gadgets (infinity stones) at finger tips (personal computer desktop) with local area network for safe and effective practice during COVID-19 crises


1 Department of Glaucoma and Research, Mahathma Eye Hospital Private Limited, Trichy, Tamil Nadu, India
2 Department of Glaucoma, Sathyan Eye Care Hospital and Coimbatore Glaucoma Foundation, Coimbatore, Tamil Nadu, India
3 Department of Cataract and Refractive Surgery, Mahathma Eye Hospital Private Limited, Trichy, Tamil Nadu, India
4 Department of Paediatric Ophthalmology and Strabismus, Mahathma Eye Hospital Private Limited, Trichy, Tamil Nadu, India

Date of Web Publication31-Dec-2020

Correspondence Address:
Dr. Prasanna V Ramesh
Mahathma Eye Hospital Private Limited, No.6, Seshapuram, Thennur, Trichy - 620 017, Tamil Nadu
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijo.IJO_2609_20

Rights and Permissions

How to cite this article:
Ramesh PV, Parthasarthi S, Ramesh SV, Rajasekaran R, Ramesh MK. Interconnecting ophthalmic gadgets (infinity stones) at finger tips (personal computer desktop) with local area network for safe and effective practice during COVID-19 crises. Indian J Ophthalmol 2021;69:449-52

How to cite this URL:
Ramesh PV, Parthasarthi S, Ramesh SV, Rajasekaran R, Ramesh MK. Interconnecting ophthalmic gadgets (infinity stones) at finger tips (personal computer desktop) with local area network for safe and effective practice during COVID-19 crises. Indian J Ophthalmol [serial online] 2021 [cited 2021 Mar 2];69:449-52. Available from: https://www.ijo.in/text.asp?2021/69/2/449/305775



Dear Editor,

Claiming the six infinity stones and interconnecting them in the gauntlet (in Marvel Cinematic Universe) gives the wielder tremendous power. Similarly in this pandemic, we have innovated a coronicle (corona + cubicle) for examining all outpatient department (OPD) patients and interconnected inside it all the ophthalmic gadgets (fundus photography, optical coherence tomography, corneal topography, visual field analyzer, optical biometry, web browser and electronic medical record (EMR) to the personal computer (PC) by Local Area Network (LAN) [Figure 1] and [Figure 2].[1] The coronicle was innovated for all OPD patients following the COVID-19 pandemic lockdown to ensure the safety of the ophthalmic service provider as well as the patients attending the OPD services.
Figure 1: Infinity tools of an ophthalmologist

Click here to view
Figure 2: (a) Connecting all ophthalmic gadgets inside the coronicle (corona + cubicle) with a eight port switch. (b). Magnified view of the eight port switch

Click here to view


Setting up the LAN Framework

The LAN networking is established by an eight-port switch [Figure 3]a present inside the coronicle which finally relays to the CISCO (Commercial and Industry Security Corporation Switch) switch [Figure 3]b outside.[2] CISCO enables connected devices to share information and communicate with each other connected on the same network within the building. It also connects wireless access points, printers and servers on the same network for additional facilities.[2] A working example of setting up a LAN connection, assigning an IP (internet protocol) address and screen mirroring the data are shown [Figure 4],[Figure 5],[Figure 6].[3] IP address can be assigned by following these simple steps (Control Panel->Network and Internet->Network Connections->Use the following IP address) as shown in [Figure 5] in detail. In this example, we have assigned IP address of 192.168.1.17. Each ophthalmic gadget will have a unique IP address assigned. Once the IP address is assigned for that particular gadget, the same address is entered in the web browser of the PC desktop placed near the doctor's slit lamp for activating the screen sharing relay display from the machine [Figure 6].
Figure 3: (a) Eight port switch connections to/from various gadgets. (b) Commercial and Industry Security Corporation (CISCO) Switch (Yellow arrow indicates the 28 ports in CISCO)

Click here to view
Figure 4: Example of a LAN structural connection. (a). LAN cable from fundus photography machine to eight port switch. (b). LAN cable from eight port switch to laptop/PC Desktop

Click here to view
Figure 5: Steps in assigning IP address (Control Panel->Network and Internet->Network Connections->Use the following IP address). Unique assigning number for each gadget is different; (can be from 1 to 254) and is depicted by the red circe

Click here to view
Figure 6: Initiating screen mirroring from the fundus photography machine after entering IP address in the web browser

Click here to view


The role of information technology (IT) personnel may be warranted to assist the ophthalmologist for the basic integration of these pieces of equipment via LAN. For machines where LAN is not an option, interconnectivity could be achieved using a WiFi network.[4] It is called WLAN (Wireless Local Access Network). For printing the final clinical case documents, the respective images need to be downloaded to the personal computer connected via LAN with the ophthalmic gadget, in a JPEG format or PDF format and can be printed via USB (universal serial bus) cable connected to the printer.

Role of LAN in Telemedicine

Connecting with remote desktop access tools are best for telecommunication using LAN. The five best desktop access tools available are TeamViewer, SolarWinds Take Control (Free trial), AnyDesk, Chrome Remote Desktop and Microsoft Remote Desktop. For eye practitioners considering telecommunication using LAN, remote desktop access tools can be used in addition to the mandatory web interface tool for LAN which connects the device in your practice.

Advantages of LAN over electronic medical records (EMR)

How LAN has an edge over EMR software is that EMR software has fixed frame modules whereas the LAN display provides dynamic facilities such as zoom and multiple frames [Figure 7] and [Figure 8]. The data of every patient can be viewed immediately, once the patient has completed the evaluation. Also, they can be compared, side by side with their previous baseline and other investigations [Figure 9] and [Figure 10]. This serves as a smart time-saver (i.e) doctor walking time to the investigative machine can be prevented and patients can be counselled by showing their image. Finally, the patient's copy can be mailed or sent to their phone directly (from the machine through Bluetooth), so they will have the best copy for future reference [Figure 11]. By going green, multiple paper handling can be reduced, avoiding aerosol mediated infection.
Figure 7: EMR softwares versus LAN. (a). EMR has fixed frame modules. (b). LAN has dynamic features such as zoom

Click here to view
Figure 8: EMR softwares versus LAN. (a). In EMR only a single examination visual field chart can be seen at a time. (b). In LAN multiple visual field examination charts can be seen at a given time

Click here to view
Figure 9: Simultaneous comparison of two modalities on a PC desktop screen. Functional polar analysis of the superior visual field loss (black arrow) compared with structural superior neuro-retinal rim defect (red arrow)

Click here to view
Figure 10: Simultaneous comparison of two modalities on a PC desktop screen. Central serous retinopathy - Fundus photography (Yellow arrow) and OCT (red arrow)

Click here to view
Figure 11: Superiority of soft copy. (a). Soft copy (b). Hard copy with artefacts

Click here to view


Economics factor

Even today, majority eye care professionals invest in EMR than the cost-effective LAN because of lack of awareness of the advantages of LAN. Costing of CISCO server [Fig. 3b] with the switch is approximately one lakh, costing of eight-port switch [Fig. 2b] is approximately 5000 rupees and wiring required to achieve the LAN network may cost approximately 5000 rupees depending upon the area covered. Still, it is relatively cost-effective compared to an EMR.

We ophthalmologists who face an additional difficulty due to the proximity of evaluation and various entity of diagnostic procedures that have now become mandatory for an eclectic setup can avoid the proximity of evaluation with the help of LAN. According to our knowledge, there is no publication in literature depicting this novel technique of holistic comprehensive LAN usage for all gadgets in ophthalmic practice. Interconnecting one tool with the other enhances the functionality of the other by using a single internet connection and be accessed and controlled by one another. This simple modification can help us continue our routine OPD services in a much safe way.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
  References Top

1.
What is LAN? - Google Search [Internet]. [cited 2020 Aug 11];Available from: https://www.cisco.com/c/en/us/products/switches/what-is-a-lan-local-area-network.html.  Back to cited text no. 1
    
2.
“Cisco, Form 10-K, Annual Report, Filing Date Sep 12, 2012”. Available from: secdatabase.com. [Last retrieved on 2013 Mar 25].  Back to cited text no. 2
    
3.
RFC 760, DOD Standard Internet Protocol, DARPA, Information Sciences Institute (January 1980).  Back to cited text no. 3
    
4.
Riha C. How wireless LANs can enhance the clinical environment. Biomed Instrum Technol 2004-2005;Suppl:45-8.  Back to cited text no. 4
    


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5], [Figure 6], [Figure 7], [Figure 8], [Figure 9], [Figure 10], [Figure 11]



 

Top
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
References
Article Figures

 Article Access Statistics
    Viewed976    
    Printed103    
    Emailed0    
    PDF Downloaded147    
    Comments [Add]    

Recommend this journal