LETTER TO THE EDITOR
Year : 2021  |  Volume : 69  |  Issue : 2  |  Page : 463-464

Frugal model for scleral fixated intraocular lens simulation


Department of Vitreoretina Services, Aravind Eye Hospital and Postgraduate Institute of Ophthalmology, Madurai, Tamil Nadu, India

Date of Web Publication18-Jan-2021

Correspondence Address:
Dr. Sourav Damodaran
Aravind Eye Hospital and Postgraduate Institute of Ophthalmology, Anna Nagar, Madurai,Tamil Nadu - 625 020
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ijo.IJO_2524_20

Rights and Permissions

How to cite this article:
Damodaran S, Babu N, Sen S, Arthur D, Ramasamy K. Frugal model for scleral fixated intraocular lens simulation. Indian J Ophthalmol 2021;69:463-4

How to cite this URL:
Damodaran S, Babu N, Sen S, Arthur D, Ramasamy K. Frugal model for scleral fixated intraocular lens simulation. Indian J Ophthalmol [serial online] 2021 [cited 2023 Feb 5];69:463-4. Available from: https://www.ijo.in/text.asp?2021/69/2/463/306978



Dear Editor,

Scleral fixated intraocular lens (SFIOL) has been the mode of optical rehabilitation in cases of aphakia without adequate capsular support. The results of scleral fixated IOLs have been encouraging in both adult and pediatric populations.[1],[2] There are numerous surgical techniques for SFIOL surgery, a simulator for the same is rarely available for residents/surgeons to practice. Here we introduce a simple model simulator for practicing the basic steps in SFIOL.

Materials required

  1. Ping pong ball
  2. 2 mm*2 mm rubber pads (cut out from rubber tube)
  3. Staple Pin-(No 10.) crown width 9.3 mm, leg -4 mm.


A Ping-Pong ball (Table tennis) made of plastic material is taken. A 10 mm hole is made in the ball using a knife. This hole acts as the anterior chamber. The 2 rubber cubes are pasted using superglue at a distance of 1.5 mm from the limbus on diametrically opposite points. A staple pin with a length of 9 mm is pinned 2 mm away from the limbus. The whole apparatus is mounted on a holder (thermocol with space cut to fit the ball) [Figure 1]a.
Figure 1: Microscope view of cardinal surgical steps: (a) SFIOL simulator model, (b) making scleral pockets, (c) inserting the lens, (d) externalizing the leading haptic, (e) 26-G needle assisted externalization, (f) grasping the trailing haptic, (g) externalizing the trailing haptic, (h) haptic tucking, and (i) Final scleral fixated IOL

Click here to view


Surgical simulation

Materials required for surgical simulation include 6.5 mm rigid PMMA lens, 23G needle with a syringe, 26-G needle with the syringe for haptic exteriorization, 23 G forceps, IOL holding forceps. Refer attached video 1 for surgical steps.




Steps

[Figure 1] shows the intraoperative steps while [Figure 2] shows the major steps as seen from outside.
Figure 2: Surgical steps viewed from outside: (a) inserting lens and grasping the leading haptic, (b) needle assisted externalization of leading haptic, (c) using a rubber stopper to prevent haptic slippage, (d) externalization of trailing haptic

Click here to view


  1. Scleral pockets are made in the rubber pads using a 23 G trocar. Also adjacent to the scleral pocket 23 G sclerotomy is made [Figure 1]b
  2. The lens is held using forceps and advanced to pupillary area through the staple pin which acts as the scleral tunnel [Figure 1]c
  3. The leading haptic is exteriorized using a forceps [Figure 1]d and [Figure 2]a or by threading into a 26 G needle [Figure 1]e and [Figure 2]b
  4. The trailing haptic is exteriorized using a forceps [Figure 1]f, [Figure 1]g, and [Figure 2]d
  5. The haptics are tucked into the created scleral pockets [Figure 1]h, to obtain a centered scleral fixated IOL [Figure 1]i.


This technique can be repeated multiple times using the same model.

Gabor and Pallavidis described the original surgical technique used for creating this simulator.[3] In this technique, the scleral tunnels have been demonstrated to be leak free even without glue.[4] Also since the haptics are inside the sclera there is lesser chances of conjunctival erosion due to the haptics.

This model enables the surgeon to practice insertion of IOL, grasping the leading haptic, exteriorizing it via sclerotomy. This will also enhance hand-eye coordination and improve bidextrous surgical maneuvers. The needle assisted exteriorization can also be practiced with this model.[5] The externalizing leading haptic may be stabilized using a rubber stopper, to prevent inadvertent slippage while manipulating the trailing haptic [Figure 2]c. After this step the trailing haptic is exteriorized directly using a forceps. The lens haptics are tucked into the rubber pads and adjusted accordingly for centration. The lens centration in this technique is adjusted by titrating the amount of intrascleral haptic length. The Yamane technique of SFIOL, where haptics are cauterized and left sub conjuctival may also be performed using the same model.[6]

The limitations include the absence of corneal tissue, which could have given more originality for the model. Also it would have enabled formation of a closed anterior chamber. There is also lack of orbital adnexal structures which can limit the hand movements of the surgeon. However, this drawback can be overcome by placing the model over a mannequin head.

Even though, this simple model can enable surgeon to practice cardinal steps of intrascleral fixation of IOL. It can fasten the acquiring of surgical skills among the trainees.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
  References Top

1.
Vote BJ, Tranos P, Bunce C, Charteris DG, Da Cruz L. Long-term outcome of combined pars plana vitrectomy and scleral fixated sutured posterior chamber intraocular lens implantation. Am J Ophthalmol 2006;141:308-12.  Back to cited text no. 1
    
2.
NB K, Kohli P, Pangtey BPS, Ramasamy K. Evaluation of sutureless, glueless, flapless, intrascleral fixated posterior chamber intraocular lens in children with ectopia lentis. J Ophthalmol 2018;2018:3212740.  Back to cited text no. 2
    
3.
Gabor SG, Pavlidis MM. Sutureless intrascleral posterior chamber intraocular lens fixation. J Cataract Refract Surg 2007;33:1851-4.  Back to cited text no. 3
    
4.
Scharioth GB, Prasad S, Georgalas I, Tataru C, Pavlidis M. Intermediate results of sutureless intrascleral posterior chamber intraocular lens fixation. J Cataract Refract Surg 2010;36:254-9.  Back to cited text no. 4
    
5.
Baskaran P, Ganne P, Bhandari S, Ramakrishnan S, Venkatesh R, Gireesh P. Extraocular needle- guided haptic insertion technique of scleral fixation intraocular lens surgeries (X-NIT). Indian J Ophthalmol 2017;65:747-50.  Back to cited text no. 5
[PUBMED]  [Full text]  
6.
Yamane S, Sato S, Maruyama-Inoue M, Kadonosono K. Flanged intrascleral intraocular lens fixation with double-needle technique. Ophthalmology 2017;124:1136-42.  Back to cited text no. 6
    


    Figures

  [Figure 1], [Figure 2]



 

Top
 
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
References
Article Figures

 Article Access Statistics
    Viewed864    
    Printed6    
    Emailed0    
    PDF Downloaded46    
    Comments [Add]    

Recommend this journal