%A Kelkar, U
%A Kelkar, S
%A Bal, Abhijit
%A Kulkarni, S
%A Kulkarni, S
%T Microbiological evaluation of various parameters in ophthalmic operating rooms. The need to establish guidelines.
%9 Original Article
%D 2003
%J Indian Journal of Ophthalmology
%P 171-176
%V 51
%N 2
%U https://journals.lww.com/ijo/pages/default.aspx/article.asp?issn=0301-4738;year=2003;volume=51;issue=2;spage=171;epage=176;aulast=Kelkar
%8 April 1, 2003
%X Purpose: Postoperative infections can be caused by a contaminated environment, unsterile equipment, contaminated surfaces, and infected personnel as well as contaminated disinfectants. In order to establish guidelines for microbiological monitoring, a detailed microbiological surveillance was carried out in an ophthalmic hospital.
Method: Over a period of 21 months, we assessed environmental Bacteria Carrying Particle (BCP) load and surface samples weekly (n=276); the autoclaving system once a month and repeated whenever the process failed (n= 24); the air conditioning filters for fungal growth once in four months (n = 15), and the disinfectant solution for contamination once in two months (n = 10). Additionally, the personnel involved directly in surgery were screened for potential pathogens such as Staphylococcus aureus and β haemolytic streptococci.
Result: On 14 (5.07%) occasions the environment in the operating rooms had a significant risk of airborne infections. Sterilisation of instruments in the autoclaves was unsatisfactory on 4 (16.66 %) occasions. Samples from the filters of the air-conditioning units yielded potentially pathogenic fungi on 3 (20%) occasions. Personnel sampling revealed that 5 (8.77%) individuals harboured β haemolytic Streptococci in the throat and 4 (7.01 %) harboured S. aureus in the nasal cavity. The samples of disinfectant in use were not contaminated.
Conclusion: There is a need to standardise microbiological evaluation protocols for operating rooms.