TY - JOUR A1 - Vasavada, Viraj A1 - Vasavada, Abhay A1 - Dhanasekaran, Vijayevarshcini A1 - Vasavada, Vaishali A1 - Sudhalkar, Aditya A1 - Vasavada, Shail A1 - Srivastava, Samaresh A1 - Bilgic, Alper T1 - Cortical aspiration - The “POPS” technique Y1 - 2020/12/1 JF - Indian Journal of Ophthalmology JO - Indian J Ophthalmol SP - 2476 EP - 2478 VL - 68 IS - 11 UR - https://journals.lww.com/ijo/pages/default.aspx/article.asp?issn=0301-4738;year=2020;volume=68;issue=11;spage=2476;epage=2478;aulast=Vasavada DO - 10.4103/ijo.IJO_2384_19 N2 - In the present study, we describe a step-by-step technique for cortex aspiration during cataract surgery- POPS (positioning, occlusion, posterior displacement, and swiping). Firstly, the aspiration probe is positioned under the bulk of cortical fibers beyond the capsulorhexis margin. Subsequently, the aspiration port is occluded with minimal vacuum, and the occluded port is displaced posteriorly to detach the cortical fibers off the anterior capsule. Now, tangential, arc-like swiping movements are performed while gradually increasing vacuum at the same time. The fibers are brought to the center and finally aspirated. This allows complete removal of the equatorial fibers and lens epithelial cells (LEC) with the least stress to the capsulozonular complex. Unlike the conventional technique, which involves the radial pull of cortical fibers, in this technique, there is swiping and posterior displacement of the cortical fibers before pulling towards the center and aspirating. We believe this technique will ensure safer, more effective cortical and LEC removal, reducing zonular stress. ER -