The effects of vıtal dyes on mechanıcal propertıes of the human anterıor lens capsule


Cem Simsek1, Onur Gokmen2 
1 Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan; Department of Ophthalmology, Sitki Kocman University, Mugla, Turkey
2 Department of Ophthalmology, Health Sciences University Van Education and Training Hospital, Van, Turkey

Correspondence Address:
Dr. Onur Gokmen
Department of Ophthalmology, Health Sciences University Van Education and Training Hospital, Süphan Mahallesi Hava Yolu Kavşağı 1. Kilometre Edremit, 65300, Van
Turkey

Purpose: The purpose of this study was to evaluate the mechanical effects of vital dyes on the anterior lens capsule via the nanoindentation method. Methods: Twenty anterior lens capsules of 20 different patients were dissected into four equal fragments. Each fragment was stained separately with dyes for intraocular surgeries, such as trypan blue 0.06% (TB), brilliant blue 0.025% (BB), and indocyanine green 0.05% (ICG), for 1 min. The remaining fragment was assessed as an untreated control group. The alterations on the mechanical characteristics of the anterior lens capsule were evaluated using a nanoindentation testing device with Oliver–Pharr and Martens hardness methods. Results: The mean values of elasticity were 7.842 ± 0.55 GPa for capsules fragments stained with TB (P < 0.05), 8.407 ± 0.82 GPa for capsules fragments stained with BB (P < 0.05), 8.557 ± 0.60 GPa for ICG (P < 0.05), and 6.09 ± 0.57 GPa for the untreated control group. The mean values of stiffness were 299.7 ± 47 MPa for TB (P < 0.05), 317.9 ± 34 MPa for BB (P < 0.05), 331.8 ± 48 MPa for ICG (P < 0.05), and 229.85 ± 44 MPa for the untreated control group. The elasticity of the capsules statistically decreased in comparison to the control group, and the capsule stiffness showed a statistically significant increase in comparison to the untreated controls. Conclusion: The mechanical characteristics of the human anterior lens capsule were affected in association with the alterations in the elasticity and stiffness properties of the capsule as a result of exposure to three different dyes.


How to cite this article:
Simsek C, Gokmen O. The effects of vıtal dyes on mechanıcal propertıes of the human anterıor lens capsule.Indian J Ophthalmol 2020;68:66-70


How to cite this URL:
Simsek C, Gokmen O. The effects of vıtal dyes on mechanıcal propertıes of the human anterıor lens capsule. Indian J Ophthalmol [serial online] 2020 [cited 2020 Oct 24 ];68:66-70
Available from: https://www.ijo.in/article.asp?issn=0301-4738;year=2020;volume=68;issue=1;spage=66;epage=70;aulast=Simsek;type=0